Comparison of the accuracy of dental implant placement using static and dynamic computer-assisted systems: an in vitro study

被引:14
|
作者
Zhou, Miao [1 ]
Zhou, Hui [1 ,2 ]
Li, Shu-Yi [1 ]
Zhu, Yi-Bo [3 ]
Geng, Yuan-Ming [4 ]
机构
[1] Guangzhou Med Univ, Affiliated Stomatol Hosp, Dept Oral & Maxillofacial Surg, Guangzhou Key Lab Basic & Appl Res Oral Regenerat, Huangshadadao Rd 39, Guangzhou 510182, Peoples R China
[2] Eighth People Hosp Guangzhou, Dept Stomatol, Huayinglu Rd 8, Guangzhou 510060, Peoples R China
[3] Peking Univ, Dent Ctr 4, Sch & Hosp Stomatol, Dongsihuanzhonglu Rd 41, Beijing 100025, Peoples R China
[4] Southern Med Univ, Zhujiang Hosp, Dept Stomatol, Gongyedadaozhong Rd 253, Guangzhou 510282, Peoples R China
基金
中国国家自然科学基金;
关键词
Dental implant; Computer-assisted system; Accuracy; Model study; REGISTRATION METHODS; GUIDED SURGERY; NAVIGATION; TEMPLATE; CAD/CAM; BONE;
D O I
10.1016/j.jormas.2020.11.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The study aimed to compare the accuracy of implant placement between static and dynamic computer-assisted systems (CAS) in a partially edentulous mandible model. Materials & Methods: A total of 80 implants was placed in mandible models. The implants were placed using either static or dynamic computer-assisted system. Deviations of implant hex, apex and angulation were measured between preoperative planning and postoperative CBCT in planning software. Results: The mean deviations of implant hex, apex and angulation in static CAS group were 1.15 +/- 0.34 mm, 1.37 +/- 0.38 mm and 2.60 +/- 1.11 degree, while in dynamic CAS group were 0.40 +/- 0.41 mm, 0.34 +/- 0.33 mm and 0.97 +/- 1.21 degree, respectively. Implant placement with dynamic CAS showed less deviations of shoulder, apex and angulation than with static CAS significantly. Conclusions: The implant accuracy using CAS system could be influenced by the guiding technique. (C) 2020 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:343 / 348
页数:6
相关论文
共 50 条
  • [31] Accuracy of implant placement via dynamic navigation and autonomous robotic computer-assisted implant surgery methods: A retrospective study
    Zhang, Sihui
    Cai, Qin
    Chen, Weiyi
    Lin, Yuxuan
    Gao, Yan
    Wu, Dong
    Chen, Jiang
    CLINICAL ORAL IMPLANTS RESEARCH, 2024, 35 (02) : 220 - 229
  • [32] Seating accuracy of implant immediate provisional prostheses fabricated by digital workflow prior to implant placement by fully guided static computer-assisted implant surgery: An in vitro study
    Abduo, Jaafar
    Lau, Douglas
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (05) : 608 - 618
  • [33] Accuracy of dental implants positioning in computer-assisted surgeries: In vitro study
    Alpaca Zevallos, Erick Andres
    Ferreira Lima, Luciano Henrique
    Cortellazzi Mendes, Karine Laura
    Sverzut, Alexander Tadeu
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2024, 125 (05)
  • [34] Comparison of precision of implant placement between two different guided systems for static computer-assisted implant surgery: A simulation-based experimental study
    Pattanasirikun, Papon
    Arunjaroensuk, Sirida
    Panya, Sappasith
    Subbalekha, Keskanya
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    JOURNAL OF DENTAL SCIENCES, 2024, 19 : S38 - S43
  • [35] Accuracy of immediate anterior implantation using static and robotic computer-assisted implant surgery: A retrospective study
    Li, Jun
    Dai, Meng
    Wang, Siwei
    Zhang, Xitao
    Fan, Qin
    Chen, Lin
    JOURNAL OF DENTISTRY, 2024, 148
  • [36] Accuracy of static computer-assisted implant placement in anterior and posterior sites by clinicians new to implant dentistry: in vitro comparison of fully guided, pilot-guided, and freehand protocols
    Jaafar Abduo
    Douglas Lau
    International Journal of Implant Dentistry, 6
  • [37] Accuracy of robotic computer-assisted implant surgery for immediate implant placement: A retrospective case series study
    Li, Ping
    Zhao, Chunhui
    Chen, Jiahao
    Xu, Shulan
    Yang, Shuo
    Li, An
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2024, 26 (06) : 1279 - 1288
  • [38] Accuracy of static computer-assisted implant placement in anterior and posterior sites by clinicians new to implant dentistry: in vitro comparison of fully guided, pilot-guided, and freehand protocols
    Abduo, Jaafar
    Lau, Douglas
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2020, 6 (01)
  • [39] Accuracy assessment of computer-assisted flapless implant placement in partial edentulism
    Van Assche, N.
    van Steenberghe, D.
    Quirynen, M.
    Jacobs, R.
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2010, 37 (04) : 398 - 403
  • [40] Precision and trueness of computer-assisted implant placement using static surgical guides with open and closed sleeves: An in vitro analysis
    Guentsch, Arndt
    An, Hongseok
    Dentino, Andrew R.
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (04) : 441 - 450