Accuracy of dental implants positioning in computer-assisted surgeries: In vitro study

被引:0
|
作者
Alpaca Zevallos, Erick Andres [1 ]
Ferreira Lima, Luciano Henrique [1 ]
Cortellazzi Mendes, Karine Laura [2 ]
Sverzut, Alexander Tadeu [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Oral Diag, UNICAMP, Piracicaba, SP, Brazil
[2] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Hlth Sci & Childrens Dent, UNICAMP, Piracicaba, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Dental implants; Oral surgery; Data accuracy; Surgery; computer-assisted; GUIDED SURGERY; TEMPLATE; PLACEMENT; DENTISTRY; TOMOGRAPHY;
D O I
10.1016/j.jormas.2024.101828
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study is to presents an experimental method for surgical guide confection using an intraoral scanner to obtain a 3D model of the patient's complete denture and compare its accuracy with the conventional methodology using computed tomography. Study design: This prospective in-vitro study used 30 polyurethane pre-manufactured mandibles which were divided into two groups, conventional technique (group I) and a new method using intraoral scanner (group II), establishing the virtually planned position of the dental implants as a control group, considered as the gold standard for postoperative comparison. Results: The difference between these methods is close to zero and not statistically significant (p > 0.05), being heigh deviation (Xh) with p:0.130 and angulation difference of dental implants between the groups (Ang) with p:0.396. Conclusion: The acquisition of stereolithography image of the prosthesis using an intraoral scanner has a clinically acceptable accuracy, being in agreement with the conventional method. (c) 2024 Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Accuracy tests for the computer-assisted insertion of dental implants at the phantom model of the lower jaw
    Schneider, M
    Eckelt, U
    Hietschold, V
    CARS 2000: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2000, 1214 : 938 - 944
  • [2] Comparison of the accuracy of dental implant placement using static and dynamic computer-assisted systems: an in vitro study
    Zhou, Miao
    Zhou, Hui
    Li, Shu-Yi
    Zhu, Yi-Bo
    Geng, Yuan-Ming
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2021, 122 (04) : 343 - 348
  • [3] Accuracy of dental implant placement using static versus dynamic computer-assisted implant surgery: An in vitro study
    Otaghsara, Seyedeh Sahar Taheri
    Joda, Tim
    Thieringer, Florian Markus
    JOURNAL OF DENTISTRY, 2023, 132
  • [4] COMPUTER-ASSISTED INTRAOPERATIVE VISUALIZATION OF DENTAL IMPLANTS - AUGMENTED REALITY IN MEDICINE
    PLODER, O
    WAGNER, A
    ENISLIDIS, G
    EWERS, R
    RADIOLOGE, 1995, 35 (09): : 569 - 572
  • [5] COMPUTER-ASSISTED DENTAL DIAGNOSIS
    RALLS, SA
    COHEN, ME
    SOUTHARD, TE
    DENTAL CLINICS OF NORTH AMERICA, 1986, 30 (04) : 695 - 712
  • [6] Accuracy of dynamic computer-assisted implant surgery in fully edentulous patients: An in vitro study
    Ruiz-Romero, Victor
    Jorba-Garcia, Adria
    Camps-Font, Octavi
    Figueiredo, Rui
    Valmaseda-Castellon, Eduard
    JOURNAL OF DENTISTRY, 2024, 149
  • [7] An In Vitro Study on the Accuracy of a Splint for the Transfer of Dental Implants
    Galindo, Rommy Chalacan
    Tipantuna, Angel Tul
    Araque, Maria Flores
    Poussin, Lupe
    Ron, Byron Velasquez
    PROSTHESIS, 2024, 6 (06): : 1575 - 1585
  • [8] Computer-assisted design of orbital implants
    Zhang, Xing
    Chen, Songling
    Huang, Yuanliang
    Chang, Shixin
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (01) : 132 - 137
  • [9] Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study
    Takacs, Anna
    Marada, Gyula
    Turzo, Kinga
    Nagy, Akos
    Nemeth, Orsolya
    Mijiritsky, Eitan
    Kivovics, Marton
    Muhl, Attila
    BMC ORAL HEALTH, 2023, 23 (01)
  • [10] Does implant drill design influence the accuracy of dental implant placement using static computer-assisted implant surgery? An in vitro study
    Anna Takács
    Gyula Marada
    Kinga Turzó
    Ákos Nagy
    Orsolya Németh
    Eitan Mijiritsky
    Márton Kivovics
    Attila Mühl
    BMC Oral Health, 23