Comparison of the accuracy of dental implant placement using static and dynamic computer-assisted systems: an in vitro study

被引:14
|
作者
Zhou, Miao [1 ]
Zhou, Hui [1 ,2 ]
Li, Shu-Yi [1 ]
Zhu, Yi-Bo [3 ]
Geng, Yuan-Ming [4 ]
机构
[1] Guangzhou Med Univ, Affiliated Stomatol Hosp, Dept Oral & Maxillofacial Surg, Guangzhou Key Lab Basic & Appl Res Oral Regenerat, Huangshadadao Rd 39, Guangzhou 510182, Peoples R China
[2] Eighth People Hosp Guangzhou, Dept Stomatol, Huayinglu Rd 8, Guangzhou 510060, Peoples R China
[3] Peking Univ, Dent Ctr 4, Sch & Hosp Stomatol, Dongsihuanzhonglu Rd 41, Beijing 100025, Peoples R China
[4] Southern Med Univ, Zhujiang Hosp, Dept Stomatol, Gongyedadaozhong Rd 253, Guangzhou 510282, Peoples R China
基金
中国国家自然科学基金;
关键词
Dental implant; Computer-assisted system; Accuracy; Model study; REGISTRATION METHODS; GUIDED SURGERY; NAVIGATION; TEMPLATE; CAD/CAM; BONE;
D O I
10.1016/j.jormas.2020.11.008
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The study aimed to compare the accuracy of implant placement between static and dynamic computer-assisted systems (CAS) in a partially edentulous mandible model. Materials & Methods: A total of 80 implants was placed in mandible models. The implants were placed using either static or dynamic computer-assisted system. Deviations of implant hex, apex and angulation were measured between preoperative planning and postoperative CBCT in planning software. Results: The mean deviations of implant hex, apex and angulation in static CAS group were 1.15 +/- 0.34 mm, 1.37 +/- 0.38 mm and 2.60 +/- 1.11 degree, while in dynamic CAS group were 0.40 +/- 0.41 mm, 0.34 +/- 0.33 mm and 0.97 +/- 1.21 degree, respectively. Implant placement with dynamic CAS showed less deviations of shoulder, apex and angulation than with static CAS significantly. Conclusions: The implant accuracy using CAS system could be influenced by the guiding technique. (C) 2020 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:343 / 348
页数:6
相关论文
共 50 条
  • [41] Influence of template design on the accuracy of static computer-assisted implant surgery
    Chung, Jinmook
    Park, Junghyun
    Son, Hyeonseong
    Hong, Seoung-Jin
    Pae, Ahran
    JOURNAL OF ADVANCED PROSTHODONTICS, 2025, 17 (01): : 22 - 35
  • [42] Digital Evaluation of the Accuracy of Computer-Guided Dental Implant Placement: An In Vitro Study
    Kim, Seong-Min
    Son, Keunbada
    Kim, Duk-Yeon
    Lee, Kyu-Bok
    APPLIED SCIENCES-BASEL, 2019, 9 (16):
  • [43] Does dynamic navigation assisted student training improve the accuracy of dental implant placement by postgraduate dental students: an in vitro study
    Yan, Qi
    Wu, Xinyu
    Shi, Junyu
    Shi, Bin
    BMC ORAL HEALTH, 2024, 24 (01):
  • [44] Accuracy of Computer-Assisted Dynamic Navigation as a Function of Different Intraoral Reference Systems: An In Vitro Study
    Schnutenhaus, Sigmar
    Knipper, Anne
    Wetzel, Martin
    Edelmann, Cornelia
    Luthardt, Ralph
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2021, 18 (06) : 1 - 13
  • [45] Accuracy of dental implant surgery using dynamic navigation and robotic systems: An in vitro study
    Tao, Baoxin
    Feng, Yuan
    Fan, Xingqi
    Zhuang, Minjie
    Chen, Xiaojun
    Wang, Feng
    Wu, Yiqun
    JOURNAL OF DENTISTRY, 2022, 123
  • [46] Positional accuracy during the sequence of static computer-assisted implant surgery in three alveolar ridge morphologies: An in vitro study
    Raabe, Clemens
    Abou-Ayash, Samir
    Yilmaz, Burak
    Surbek, Fiona Jennifer
    Chappuis, Vivianne
    Couso-Queiruga, Emilio
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025, 34 (01): : 78 - 85
  • [47] Effect of Clinical Experience on Accuracy of Implant Placement Using Dynamic Navigation and Static Guidance: An In Vitro Study
    Fang, Qiao
    Lozada, Jaime
    Kan, Joseph
    Al-Ardah, Aladdin
    Li, Yiming
    JOURNAL OF ORAL IMPLANTOLOGY, 2024, 50 (06) : 626 - 635
  • [48] Computer-assisted bone augmentation, implant planning and placement: An in vitro investigation
    Unger, S.
    Benic, G. I.
    Ender, A.
    Pasic, P.
    Hammerle, C. H. F.
    Stadlinger, B.
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 (07) : 719 - 726
  • [49] Accuracy of Computer-Assisted Dynamic Navigation in Implant Placement with a Fully Digital Approach: A Prospective Clinical Trial
    Edelmann, Cornelia
    Wetzel, Martin
    Knipper, Anne
    Luthardt, Ralph G.
    Schnutenhaus, Sigmar
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (09)
  • [50] The Accuracy of Dental Implant Placement With Different Methods of Computer-Assisted Implant Surgery: A Network Meta-Analysis of Clinical Studies
    Mahardawi, Basel
    Jiaranuchart, Sirimanas
    Arunjaroensuk, Sirida
    Dhanesuan, Kanit
    Mattheos, Nikos
    Pimkhaokham, Atiphan
    CLINICAL ORAL IMPLANTS RESEARCH, 2025, 36 (01) : 1 - 16