Zirconia Cantilever Fixed Dental Prostheses Supported by One or Two Implants: An In Vitro Study on Mechanical Stability and Technical Outcomes

被引:3
|
作者
Karasan, Duygu [1 ]
Canay, Senay [2 ]
Sailer, Irena [1 ]
Att, Wael [3 ]
机构
[1] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, Michel Servet 1, CH-1211 Geneva, Switzerland
[2] Hacettepe Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey
[3] Tufts Univ, Sch Dent Med, Dept Prosthodont, Boston, MA 02111 USA
关键词
dental implants; fixed dental prosthesis; cantilever; zirconia; highly translucent zirconia; OCCLUSAL CONTACT AREA; MAXIMAL BITE FORCE; COMPLICATION RATES; FRACTURE-TOUGHNESS; ANTERIOR MAXILLA; PARTIAL DENTURES; AESTHETIC ZONE; SINGLE CROWNS; RESTORATIONS; SURVIVAL;
D O I
10.11607/jomi.8953
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the mechanical stability of highly translucent zirconia (Zr) cantilevered fixed dental prostheses (cFDPs) and to investigate the influence of the number of implants (one versus two) supporting cFDPs with different restorative materials on their mechanical stability and load-bearing capacity. Materials and Methods: Thirty-two specimens consisting of implant-supported prostheses embedded in resin blocks were fabricated. Sixteen specimens received one implant (bone-level implant, 4.1-mm diameter, 13-mm length; Straumann) to support two-unit cement-retained cFDPs with one extension unit and the other 16 received two implants (bone-level implant, 4.1-mm diameter, 13-mm length; Straumann) positioned corresponding to the missing maxillary central incisors to support three-unit cement-retained cFDPs with one extension unit. Two different prosthetic materials, chromium-cobalt (Cr-Co; Wirobond C+, Bego) and highly translucent Zr (Lava Plus, 3M ESPE) were selected to fabricate the two- and three-unit cFDPs. Standardized two-and three-unit Cr-Co frameworks (CC-I, n = 8; CC-II, n = 8) and highly translucent Zr frameworks (Zr-I, n = 8; Zr-II, n = 8) with a 6-mm cantilever extension were fabricated using CAD/CAM (EOS M 290). Following thermomechanical fatigue loading, the specimens were tested for fracture resistance under static loading. The influence of restoration material and number of supporting implants on fracture resistance were tested using two-way analysis of variance (ANOVA). The level of statistical significance was set below 5% (alpha<.05). Results: All specimens survived aging. The mean (+/- standard deviation) fracture resistance values were 416.25 (+/- 42.71) N for Zr-I, 548.75 (+/- 75.41) N for Zr-II, 601.0 (+/- 41.51) N for CC-I, and 664.5 (+/- 37.59) N for CC-II. CC and Zr group specimens showed significantly different fracture resistance results (P<.001). The number of implants significantly influenced the fracture resistance of Zr groups (P=.001), whereas the influence was not significant for CC groups (P=.089). Conclusion: Within the limitations of this in vitro study, highly translucent zirconia cFDP frameworks demonstrated the potential to withstand reported physiologic occlusal forces applied in the anterior region. The increase in the number of implants supporting zirconia cFDPs significantly contributed to achieving higher fracture resistance values.
引用
收藏
页码:748 / 755
页数:8
相关论文
共 50 条
  • [41] Difference in marginal bone loss around implants between short implant-supported partial fixed prostheses with and without cantilever: a retrospective clinical study
    Josef Al-Kilani
    Sedef Al-Kilani
    Bruno Ramos Chrcanovic
    International Journal of Implant Dentistry, 9
  • [42] Load bearing capacity of 3-unit screw-retained implant-supported fixed dental prostheses with a mesial and distal cantilever on a single implant: A comparative in vitro study
    Molinero-Mourelle, Pedro
    Abou-Ayash, Samir
    Bragger, Urs
    Schimmel, Martin
    Ozcan, Mutlu
    Yilmaz, Burak
    Buser, Ramona
    Al-Haj Husain, Nadin
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2024, 151
  • [43] Benchmarking Outcomes in Implant Prosthodontics: Partial Fixed Dental Prostheses and Crowns Supported by Implants with a Turned Surface over 10 to 28 Years at the University of Toronto
    Jokstad, Asbjorn
    Gussgard, Anne M.
    Fava, Joseph
    Lin, Mark
    Shokati, Babak
    Somogyi-Ganss, Eszter
    Winnett, Brenton
    Zahran, Mohammed
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (04) : 880 - 892
  • [44] Accuracy of the Different Materials Used to Fabricate a Verification Jig of Implant-Supported Fixed Complete Dental Prostheses: An In Vitro Study
    Aljohani, Mawaddah S.
    Bukhari, Heba A.
    Alshehri, Mayar
    Alamoudi, Ahmed
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)
  • [45] Mechanical stability of all-ceramic abutments retained with three different screw materials in two-piece zirconia implants—an in vitro study
    Michael Stimmelmayr
    Anna Lang
    Florian Beuer
    Sonia Mansour
    Kurt Erdelt
    Gerald Krennmair
    Jan-Frederik Güth
    Clinical Oral Investigations, 2020, 24 : 1801 - 1806
  • [46] Clinical Results and Technical Complications of Posterior Implant-Supported Modified Monolithic Zirconia Single Crowns and Short-Span Fixed Dental Prostheses: A 2-Year Pilot Study
    Cheng, Chih-Wen
    Chien, Chia-Hui
    Chen, Chun-Jung
    Papaspyridakos, Panos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (02): : 108 - 114
  • [47] Influence of Retainer Design on Two-unit Cantilever Resin-bonded Glass Fiber Reinforced Composite Fixed Dental Prostheses: An In Vitro and Finite Element Analysis Study
    Keulemans, Filip
    De Jager, Nike
    Kleverlaan, Cornelis J.
    Feilzer, Albert J.
    JOURNAL OF ADHESIVE DENTISTRY, 2008, 10 (05): : 355 - 364
  • [48] Assessment of the Different Types of Failure on Anterior Cantilever Resin-Bonded Fixed Dental Prostheses Fabricated with Three Different Materials: An In Vitro Study
    Di Fiore, Adolfo
    Stellini, Edoardo
    Savio, Gianpaolo
    Rosso, Stefano
    Graiff, Lorenzo
    Granata, Stefano
    Monaco, Carlo
    Meneghello, Roberto
    APPLIED SCIENCES-BASEL, 2020, 10 (12):
  • [49] Long-term outcomes and complication rates of tooth-implant-supported fixed dental prostheses: A retrospective cohort study
    Dahlgren, Simon
    Johansson, Carin Starkhammar
    Sayardoust, Shariel
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [50] Prosthetic complications of fixed dental prostheses supported by locking-taper implants: a retrospective study with a mean follow-up of 5 years
    Gao, Wen Mo
    Geng, Wei
    Luo, Chen Chen
    BMC ORAL HEALTH, 2021, 21 (01)