Zirconia Cantilever Fixed Dental Prostheses Supported by One or Two Implants: An In Vitro Study on Mechanical Stability and Technical Outcomes

被引:3
|
作者
Karasan, Duygu [1 ]
Canay, Senay [2 ]
Sailer, Irena [1 ]
Att, Wael [3 ]
机构
[1] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, Michel Servet 1, CH-1211 Geneva, Switzerland
[2] Hacettepe Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey
[3] Tufts Univ, Sch Dent Med, Dept Prosthodont, Boston, MA 02111 USA
关键词
dental implants; fixed dental prosthesis; cantilever; zirconia; highly translucent zirconia; OCCLUSAL CONTACT AREA; MAXIMAL BITE FORCE; COMPLICATION RATES; FRACTURE-TOUGHNESS; ANTERIOR MAXILLA; PARTIAL DENTURES; AESTHETIC ZONE; SINGLE CROWNS; RESTORATIONS; SURVIVAL;
D O I
10.11607/jomi.8953
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the mechanical stability of highly translucent zirconia (Zr) cantilevered fixed dental prostheses (cFDPs) and to investigate the influence of the number of implants (one versus two) supporting cFDPs with different restorative materials on their mechanical stability and load-bearing capacity. Materials and Methods: Thirty-two specimens consisting of implant-supported prostheses embedded in resin blocks were fabricated. Sixteen specimens received one implant (bone-level implant, 4.1-mm diameter, 13-mm length; Straumann) to support two-unit cement-retained cFDPs with one extension unit and the other 16 received two implants (bone-level implant, 4.1-mm diameter, 13-mm length; Straumann) positioned corresponding to the missing maxillary central incisors to support three-unit cement-retained cFDPs with one extension unit. Two different prosthetic materials, chromium-cobalt (Cr-Co; Wirobond C+, Bego) and highly translucent Zr (Lava Plus, 3M ESPE) were selected to fabricate the two- and three-unit cFDPs. Standardized two-and three-unit Cr-Co frameworks (CC-I, n = 8; CC-II, n = 8) and highly translucent Zr frameworks (Zr-I, n = 8; Zr-II, n = 8) with a 6-mm cantilever extension were fabricated using CAD/CAM (EOS M 290). Following thermomechanical fatigue loading, the specimens were tested for fracture resistance under static loading. The influence of restoration material and number of supporting implants on fracture resistance were tested using two-way analysis of variance (ANOVA). The level of statistical significance was set below 5% (alpha<.05). Results: All specimens survived aging. The mean (+/- standard deviation) fracture resistance values were 416.25 (+/- 42.71) N for Zr-I, 548.75 (+/- 75.41) N for Zr-II, 601.0 (+/- 41.51) N for CC-I, and 664.5 (+/- 37.59) N for CC-II. CC and Zr group specimens showed significantly different fracture resistance results (P<.001). The number of implants significantly influenced the fracture resistance of Zr groups (P=.001), whereas the influence was not significant for CC groups (P=.089). Conclusion: Within the limitations of this in vitro study, highly translucent zirconia cFDP frameworks demonstrated the potential to withstand reported physiologic occlusal forces applied in the anterior region. The increase in the number of implants supporting zirconia cFDPs significantly contributed to achieving higher fracture resistance values.
引用
收藏
页码:748 / 755
页数:8
相关论文
共 50 条
  • [31] In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses
    Choi, Jae-Won
    Kim, So-Yeun
    Bae, Ji-Hyeon
    Bae, Eun-Bin
    Huh, Jung-Bo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2017, 9 (04): : 244 - 251
  • [32] Clinical outcomes of all-ceramic single crowns and fixed dental prostheses supported by ceramic implants: A systematic review and meta-analyses
    Spitznagel, Frank Akito
    Balmer, Marc
    Wiedemeier, Daniel B.
    Jung, Ronald Ernst
    Gierthmuehlen, Petra Christine
    CLINICAL ORAL IMPLANTS RESEARCH, 2022, 33 (01) : 1 - 20
  • [33] Marginal and internal fit of curved anterior CAD/CAM-milled zirconia fixed dental prostheses: An in-vitro study
    Buechi, Dominik L.
    Ebler, Sabine
    Haemmerle, Christoph H. F.
    Sailer, Irena
    QUINTESSENCE INTERNATIONAL, 2014, 45 (10): : 837 - 846
  • [34] Retention Forces of Implant-Supported Single Crowns and Fixed Dental Prostheses after Cementation: An In-Vitro Study
    Bishti, Shaza
    Siouri, Jousef
    Wolfart, Stefan
    Tuna, Taskin
    ORAL, 2022, 2 (01): : 29 - 40
  • [35] Titanium- and zirconia-based implant-supported fixed dental prostheses. A randomized, prospective clinical pilot study
    Borg, Marcus
    von Steyern, Per Vult
    Larsson, Christel
    SWEDISH DENTAL JOURNAL, 2014, 38 (01) : 23 - 30
  • [36] Single and partial tooth replacement with fixed dental prostheses supported by dental implants: A systematic review of outcomes and outcome measures used in clinical trials in the last 10 years
    Sailer, Irena
    Barbato, Luigi
    Mojon, Philippe
    Pagliaro, Umberto
    Serni, Lapo
    Karasan, Duygu
    Cairo, Francesco
    CLINICAL ORAL IMPLANTS RESEARCH, 2023, 34 : 22 - 37
  • [37] Single and partial tooth replacement with fixed dental prostheses supported by dental implants: A systematic review of outcomes and outcome measures used in clinical trials in the last 10 years
    Sailer, Irena
    Barbato, Luigi
    Mojon, Philippe
    Pagliaro, Umberto
    Serni, Lapo
    Karasan, Duygu
    Cairo, Francesco
    JOURNAL OF CLINICAL PERIODONTOLOGY, 2023, 50 : 22 - 37
  • [38] Five year clinical outcomes of metal ceramic and zirconia-based implant-supported dental prostheses: A retrospective study
    Nejatidanesh, Farahnaz
    Abbasi, Mahsa
    Savabi, Ghazal
    Bonakdarchian, Morteza
    Atash, Ramin
    Savabi, Omid
    JOURNAL OF DENTISTRY, 2020, 100
  • [39] Mechanical stability and technical outcomes of monolithic CAD/CAM fabricated abutment-crowns supported by titanium bases: An in vitro study
    Pitta, Joao
    Hjerppe, Jenni
    Burkhardt, Felix
    Fehmer, Vincent
    Mojon, Philippe
    Sailer, Irena
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (02) : 222 - 232
  • [40] Difference in marginal bone loss around implants between short implant-supported partial fixed prostheses with and without cantilever: a retrospective clinical study
    Al-Kilani, Josef
    Al-Kilani, Sedef
    Chrcanovic, Bruno Ramos
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2023, 9 (01)