Zirconia Cantilever Fixed Dental Prostheses Supported by One or Two Implants: An In Vitro Study on Mechanical Stability and Technical Outcomes

被引:3
|
作者
Karasan, Duygu [1 ]
Canay, Senay [2 ]
Sailer, Irena [1 ]
Att, Wael [3 ]
机构
[1] Univ Geneva, Univ Clin Dent Med, Div Fixed Prosthodont & Biomat, Michel Servet 1, CH-1211 Geneva, Switzerland
[2] Hacettepe Univ, Dept Prosthodont, Fac Dent, Ankara, Turkey
[3] Tufts Univ, Sch Dent Med, Dept Prosthodont, Boston, MA 02111 USA
关键词
dental implants; fixed dental prosthesis; cantilever; zirconia; highly translucent zirconia; OCCLUSAL CONTACT AREA; MAXIMAL BITE FORCE; COMPLICATION RATES; FRACTURE-TOUGHNESS; ANTERIOR MAXILLA; PARTIAL DENTURES; AESTHETIC ZONE; SINGLE CROWNS; RESTORATIONS; SURVIVAL;
D O I
10.11607/jomi.8953
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the mechanical stability of highly translucent zirconia (Zr) cantilevered fixed dental prostheses (cFDPs) and to investigate the influence of the number of implants (one versus two) supporting cFDPs with different restorative materials on their mechanical stability and load-bearing capacity. Materials and Methods: Thirty-two specimens consisting of implant-supported prostheses embedded in resin blocks were fabricated. Sixteen specimens received one implant (bone-level implant, 4.1-mm diameter, 13-mm length; Straumann) to support two-unit cement-retained cFDPs with one extension unit and the other 16 received two implants (bone-level implant, 4.1-mm diameter, 13-mm length; Straumann) positioned corresponding to the missing maxillary central incisors to support three-unit cement-retained cFDPs with one extension unit. Two different prosthetic materials, chromium-cobalt (Cr-Co; Wirobond C+, Bego) and highly translucent Zr (Lava Plus, 3M ESPE) were selected to fabricate the two- and three-unit cFDPs. Standardized two-and three-unit Cr-Co frameworks (CC-I, n = 8; CC-II, n = 8) and highly translucent Zr frameworks (Zr-I, n = 8; Zr-II, n = 8) with a 6-mm cantilever extension were fabricated using CAD/CAM (EOS M 290). Following thermomechanical fatigue loading, the specimens were tested for fracture resistance under static loading. The influence of restoration material and number of supporting implants on fracture resistance were tested using two-way analysis of variance (ANOVA). The level of statistical significance was set below 5% (alpha<.05). Results: All specimens survived aging. The mean (+/- standard deviation) fracture resistance values were 416.25 (+/- 42.71) N for Zr-I, 548.75 (+/- 75.41) N for Zr-II, 601.0 (+/- 41.51) N for CC-I, and 664.5 (+/- 37.59) N for CC-II. CC and Zr group specimens showed significantly different fracture resistance results (P<.001). The number of implants significantly influenced the fracture resistance of Zr groups (P=.001), whereas the influence was not significant for CC groups (P=.089). Conclusion: Within the limitations of this in vitro study, highly translucent zirconia cFDP frameworks demonstrated the potential to withstand reported physiologic occlusal forces applied in the anterior region. The increase in the number of implants supporting zirconia cFDPs significantly contributed to achieving higher fracture resistance values.
引用
收藏
页码:748 / 755
页数:8
相关论文
共 50 条
  • [21] Five-Year Results of One-Piece Zirconia Oral Implants Supporting Three-Unit Fixed Dental Prostheses
    Kohal, Ralf-Joachim
    Vach, Kirstin
    Butz, Frank
    Patzelt, Sebastian Berthold Maximilian
    Burkhardt, Felix
    CLINICAL ORAL IMPLANTS RESEARCH, 2025,
  • [22] Acoustic resonance frequency analysis for evaluating prosthetic screw stability in splinted implant-supported fixed dental prostheses: An in vitro study
    Guo, Jiaer
    Wang, Xiaolu
    Liu, Zhixin
    Zhou, Jianying
    Wang, Lin
    JOURNAL OF PROSTHETIC DENTISTRY, 2025, 133 (02):
  • [23] Comparative Clinical Study of Three-Unit Fixed Partial Prostheses Supported by Two or Three Implants
    Yi, Yang-Jin
    Lee, Ji-Young
    Kim, Young-Kyun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2013, 28 (04) : 1110 - 1115
  • [24] Performance of zirconia ceramic cantilever fixed dental prostheses: 3-Year results from a prospective, randomized, controlled pilot study
    Zenthoefer, Andreas
    Ohlmann, Brigitte
    Rammelsberg, Peter
    Boemicke, Wolfgang
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (01): : 34 - 39
  • [25] Stability of screw-retention in two-piece zirconia implants: An in vitro study
    Joos, Marc
    Sailer, Irena
    Filippi, Andreas
    Mukaddam, Khaled
    Rosentritt, Martin
    Kuhl, Sebastian
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (07) : 607 - 614
  • [27] Analysis of the Marginal Continuity in Different Designs of Monolithic Zirconia Inlay-Retained Fixed Dental Prostheses: An In Vitro Study
    Halawani, Mohamed T. El
    Aboushady, Yehia S.
    Kader, Sally M. Abdel
    Benedicenti, Stefano
    Solimei, Luca
    Signore, Antonio
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (02) : 173 - 180
  • [28] Patient-Reported and Clinical Outcomes of Implant-Supported Fixed Complete Dental Prostheses: A Comparison of Metal-Acrylic, Milled Zirconia, and Retrievable Crown Prostheses
    Box, Virginia Hogsett
    Sukotjo, Cortino
    Knoernschild, Kent L.
    Campbell, Stephen D.
    Afshari, Fatemeh S.
    JOURNAL OF ORAL IMPLANTOLOGY, 2018, 44 (01) : 51 - 61
  • [29] Clinical and radiographic outcomes of implant-supported fixed dental prostheses with cantilever extension. A retrospective cohort study with a follow-up of at least 10 years
    Schmid, Eric
    Morandini, Michele
    Roccuzzo, Andrea
    Ramseier, Christoph A.
    Sculean, Anton
    Salvi, Giovanni E.
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (12) : 1243 - 1252
  • [30] Comparison of Implant Survival Rates and Biologic and Mechanical Complications with Implant-Supported Fixed Complete Dental Prostheses Using Four and Six Implants
    Tamer, Yusuf
    Ozcan, Isil
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2023, 43 (04) : E157 - E163