Effect of sternal electrode gap and belt rotation on the robustness of pulmonary electrical impedance tomography parameters

被引:10
|
作者
Sophocleous, L. [1 ]
Waldmann, A. D. [2 ,3 ]
Becher, T. [4 ]
Kallio, M. [5 ,6 ]
Rahtu, M. [5 ,6 ]
Miedema, M. [7 ,8 ]
Papadouri, T. [9 ]
Karaoli, C. [9 ]
Tingay, D. G. [10 ,11 ,12 ]
Van Kaam, A. H. [7 ,8 ]
Yerworth, R. [13 ]
Bayford, R. [14 ]
Frerichs, I [4 ]
机构
[1] Univ Cyprus, KIOS Res Ctr, Dept Elect & Comp Engn, Nicosia, Cyprus
[2] Rostock Univ, Dept Anaesthesiol & Intens Care Med, Med Ctr, Rostock, Germany
[3] SenTec AG, Landquart, Switzerland
[4] Univ Med Ctr Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, Campus Kiel, Kiel, Germany
[5] Univ Oulu, PEDEGO Res Unit, Oulu, Finland
[6] Oulu Univ Hosp, Dept Children & Adolescents, Oulu, Finland
[7] Univ Amsterdam, Emma Childrens Hosp, Dept Neonatol, Amsterdam UMC, Amsterdam, Netherlands
[8] Vrije Univ Amsterdam, Amsterdam, Netherlands
[9] Arch Makarios Iii Hosp, Neonatal Intens Care Unit, Nicosia, Cyprus
[10] Murdoch Childrens Res Inst, Neonatal Res, Parkville, Vic, Australia
[11] Univ Melbourne, Dept Paediat, Melbourne, Vic, Australia
[12] Royal Childrens Hosp, Neonatol, Parkville, Vic, Australia
[13] UCL, Dept Med Phys & Biomed Engn, London, England
[14] Middlesex Univ, Dept Nat Sci, London, England
基金
英国医学研究理事会;
关键词
EIT; electrical impedance; respiratory system; electrode rotation; electrode spacing; neonatal lung imaging; EIT belt; electrodes; positive end-expiratory pressure; LUNG-VOLUME; REGIONAL VENTILATION; SUSTAINED INFLATION; EIT; PRETERM; TIME; RECRUITMENT; PRESSURE; POSITION; INFANTS;
D O I
10.1088/1361-6579/ab7b42
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: Non-adhesive textile electrode belts offer several advantages over adhesive electrodes and are increasingly used in neonatal patients during continuous electrical impedance tomography (EIT) lung monitoring. However, non-adhesive belts may rotate in unsedated patients and discrepancies between chest circumference and belt sizes may result in a gap between electrodes near the sternum. This project aimed to determine the effects of belt rotation and sternal electrode gap on commonly used lung EIT parameters. Approach: We developed a simulation framework based on a 3D finite-element model and introduced lung regions with little or no ventilation that could be changed according to a decremental positive end-expiratory pressure (PEEP) trial. Four degrees of sternal gap and belt rotation were simulated and their effect on the EIT parameters silent spaces, centre of ventilation, global inhomogeneity index and overdistension/collapsed lung (OD/CL) analysed. Additionally, seven premature infants were examined to assess the influence of leftward and rightward belt rotations in a clinical setting. Main results: Small violations of the electrode equidistance criterion and rotations of the belts less than one electrode space exert only minor effects on the EIT parameters and do not impede the interpretation. Rotations of two and three electrode spaces induce non-negligible effects that might lead to flawed interpretations. The 'best PEEP' determined with the OD/CL approach was robust and identifiable with all studied sternal gaps and belt rotations.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Pulmonary perfusion measured by means of electrical impedance tomography
    Department of Pulmonary Medicine, Vrije Universiteit, Academic Hospital, Amsterdam, Netherlands
    不详
    不详
    Physiol. Meas., 2 (263-273):
  • [42] Bedside Evaluation of Pulmonary Embolism by Electrical Impedance Tomography
    Grassi, Luigi G.
    Santiago, Roberta
    Florio, Gaetano
    Berra, Lorenzo
    ANESTHESIOLOGY, 2020, 132 (04) : 896 - 896
  • [43] Determinants of pulmonary perfusion measured by electrical impedance tomography
    Henk J. Smit
    Anton Vonk Noordegraaf
    J. Tim Marcus
    Anco Boonstra
    Peter M. de Vries
    Pieter E. Postmus
    European Journal of Applied Physiology, 2004, 92 : 45 - 49
  • [44] Design and Implementation of a System of Pulmonary Electrical Impedance Tomography
    Tolabin, D. E.
    Gomez Buxo, M. D.
    Rossi, R.
    Molina, G. R.
    2016 IEEE BIENNIAL CONGRESS OF ARGENTINA (ARGENCON), 2016,
  • [45] The complete electrode model for imaging and electrode contact compensation in Electrical Impedance Tomography
    Boverman, Gregory
    Kim, Bong Seok
    Isaacson, David
    Newell, Jonathan C.
    Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings, 2007, : 3462 - 3465
  • [46] The complete electrode model for imaging and electrode contact compensation in electrical impedance tomography
    Boverman, Gregory
    Kim, Bong Seok
    Isaacson, David
    Newell, Jonathan C.
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 3462 - +
  • [47] A Mismatch Correction Method for Electrode Offset in Electrical Impedance Tomography
    Shi, Yanyan
    Lou, Yajun
    Wang, Meng
    Tian, Zhiwei
    Yang, Bin
    Fu, Feng
    IEEE SENSORS JOURNAL, 2022, 22 (07) : 7248 - 7257
  • [48] Imaging of electrode movement and conductivity change in Electrical Impedance Tomography
    Gomez-Laberge, Camille
    Adler, Andy
    2006 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-5, 2006, : 1029 - +
  • [49] A New Method for Electrical Impedance Tomography With Incomplete Electrode Array
    Sun, Benyuan
    Zhao, Yu
    Zhong, Hangyu
    Ma, Long
    Wang, Huaxiang
    IEEE SENSORS JOURNAL, 2023, 23 (18) : 21610 - 21619
  • [50] IMAGING OF ELECTRODE MOVEMENT AND CONDUCTIVITY CHANGE IN ELECTRICAL IMPEDANCE TOMOGRAPHY
    Quan, Wan
    Dinh, Anh
    2006 CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING, VOLS 1-5, 2006, : 1033 - +