Effect of sternal electrode gap and belt rotation on the robustness of pulmonary electrical impedance tomography parameters

被引:10
|
作者
Sophocleous, L. [1 ]
Waldmann, A. D. [2 ,3 ]
Becher, T. [4 ]
Kallio, M. [5 ,6 ]
Rahtu, M. [5 ,6 ]
Miedema, M. [7 ,8 ]
Papadouri, T. [9 ]
Karaoli, C. [9 ]
Tingay, D. G. [10 ,11 ,12 ]
Van Kaam, A. H. [7 ,8 ]
Yerworth, R. [13 ]
Bayford, R. [14 ]
Frerichs, I [4 ]
机构
[1] Univ Cyprus, KIOS Res Ctr, Dept Elect & Comp Engn, Nicosia, Cyprus
[2] Rostock Univ, Dept Anaesthesiol & Intens Care Med, Med Ctr, Rostock, Germany
[3] SenTec AG, Landquart, Switzerland
[4] Univ Med Ctr Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, Campus Kiel, Kiel, Germany
[5] Univ Oulu, PEDEGO Res Unit, Oulu, Finland
[6] Oulu Univ Hosp, Dept Children & Adolescents, Oulu, Finland
[7] Univ Amsterdam, Emma Childrens Hosp, Dept Neonatol, Amsterdam UMC, Amsterdam, Netherlands
[8] Vrije Univ Amsterdam, Amsterdam, Netherlands
[9] Arch Makarios Iii Hosp, Neonatal Intens Care Unit, Nicosia, Cyprus
[10] Murdoch Childrens Res Inst, Neonatal Res, Parkville, Vic, Australia
[11] Univ Melbourne, Dept Paediat, Melbourne, Vic, Australia
[12] Royal Childrens Hosp, Neonatol, Parkville, Vic, Australia
[13] UCL, Dept Med Phys & Biomed Engn, London, England
[14] Middlesex Univ, Dept Nat Sci, London, England
基金
英国医学研究理事会;
关键词
EIT; electrical impedance; respiratory system; electrode rotation; electrode spacing; neonatal lung imaging; EIT belt; electrodes; positive end-expiratory pressure; LUNG-VOLUME; REGIONAL VENTILATION; SUSTAINED INFLATION; EIT; PRETERM; TIME; RECRUITMENT; PRESSURE; POSITION; INFANTS;
D O I
10.1088/1361-6579/ab7b42
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: Non-adhesive textile electrode belts offer several advantages over adhesive electrodes and are increasingly used in neonatal patients during continuous electrical impedance tomography (EIT) lung monitoring. However, non-adhesive belts may rotate in unsedated patients and discrepancies between chest circumference and belt sizes may result in a gap between electrodes near the sternum. This project aimed to determine the effects of belt rotation and sternal electrode gap on commonly used lung EIT parameters. Approach: We developed a simulation framework based on a 3D finite-element model and introduced lung regions with little or no ventilation that could be changed according to a decremental positive end-expiratory pressure (PEEP) trial. Four degrees of sternal gap and belt rotation were simulated and their effect on the EIT parameters silent spaces, centre of ventilation, global inhomogeneity index and overdistension/collapsed lung (OD/CL) analysed. Additionally, seven premature infants were examined to assess the influence of leftward and rightward belt rotations in a clinical setting. Main results: Small violations of the electrode equidistance criterion and rotations of the belts less than one electrode space exert only minor effects on the EIT parameters and do not impede the interpretation. Rotations of two and three electrode spaces induce non-negligible effects that might lead to flawed interpretations. The 'best PEEP' determined with the OD/CL approach was robust and identifiable with all studied sternal gaps and belt rotations.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] CONTACT ADAPTING ELECTRODE MODEL FOR ELECTRICAL IMPEDANCE TOMOGRAPHY
    Darde, J.
    Hyvonen, N.
    Kuutela, T.
    Valkonens, T.
    SIAM JOURNAL ON APPLIED MATHEMATICS, 2022, 82 (02) : 427 - 449
  • [22] Accounting for erroneous electrode data in electrical impedance tomography
    Adler, A
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) : 227 - 238
  • [23] Interpolation of missing electrode data in electrical impedance tomography
    Harrach, Bastian
    INVERSE PROBLEMS, 2015, 31 (11)
  • [24] A woven electrode with convex structure for electrical impedance tomography
    Zhang, Xi
    Zhong, Yueqi
    Wang, Qi
    Dou, Chang
    TEXTILE RESEARCH JOURNAL, 2022, 92 (7-8) : 1049 - 1059
  • [25] Assessment of the unilateral pulmonary function by means of electrical impedance tomography using a reduced electrode set
    Serrano, RE
    Riu, PJ
    de Lema, B
    Casan, P
    PHYSIOLOGICAL MEASUREMENT, 2004, 25 (04) : 803 - 813
  • [26] Electrical impedance tomography with compensation for electrode positioning variations
    Blott, BH
    Daniell, GJ
    Meeson, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06): : 1731 - 1739
  • [27] JUSTIFICATION OF POINT ELECTRODE MODELS IN ELECTRICAL IMPEDANCE TOMOGRAPHY
    Hanke, Martin
    Harrach, Bastian
    Hyvonen, Nuutti
    MATHEMATICAL MODELS & METHODS IN APPLIED SCIENCES, 2011, 21 (06): : 1395 - 1413
  • [28] Comparison study of line electrode and compound electrode in electrical impedance tomography
    Wang, Yan
    Sha, Hong
    Ren, Chaoshi
    DYNAMICS OF CONTINUOUS DISCRETE AND IMPULSIVE SYSTEMS-SERIES B-APPLICATIONS & ALGORITHMS, 2006, 13E : 1565 - 1568
  • [29] Optimal Implementation Parameters of a Nonlinear Electrical Impedance Tomography Method Using the Complete Electrode Model
    Park, Jeongwoo
    Kang, Jun Won
    Choi, Eunsoo
    SENSORS, 2022, 22 (17)
  • [30] Severe pressure ulcer caused by an electrode belt for monitoring electrical impedance tomography in two patients in the prone position
    Hasegawa, Takayuki
    Yoshida, Keisuke
    Hakozaki, Takahiro
    Inoue, Satoki
    JA CLINICAL REPORTS, 2023, 9 (01)