Effect of sternal electrode gap and belt rotation on the robustness of pulmonary electrical impedance tomography parameters

被引:10
|
作者
Sophocleous, L. [1 ]
Waldmann, A. D. [2 ,3 ]
Becher, T. [4 ]
Kallio, M. [5 ,6 ]
Rahtu, M. [5 ,6 ]
Miedema, M. [7 ,8 ]
Papadouri, T. [9 ]
Karaoli, C. [9 ]
Tingay, D. G. [10 ,11 ,12 ]
Van Kaam, A. H. [7 ,8 ]
Yerworth, R. [13 ]
Bayford, R. [14 ]
Frerichs, I [4 ]
机构
[1] Univ Cyprus, KIOS Res Ctr, Dept Elect & Comp Engn, Nicosia, Cyprus
[2] Rostock Univ, Dept Anaesthesiol & Intens Care Med, Med Ctr, Rostock, Germany
[3] SenTec AG, Landquart, Switzerland
[4] Univ Med Ctr Schleswig Holstein, Dept Anaesthesiol & Intens Care Med, Campus Kiel, Kiel, Germany
[5] Univ Oulu, PEDEGO Res Unit, Oulu, Finland
[6] Oulu Univ Hosp, Dept Children & Adolescents, Oulu, Finland
[7] Univ Amsterdam, Emma Childrens Hosp, Dept Neonatol, Amsterdam UMC, Amsterdam, Netherlands
[8] Vrije Univ Amsterdam, Amsterdam, Netherlands
[9] Arch Makarios Iii Hosp, Neonatal Intens Care Unit, Nicosia, Cyprus
[10] Murdoch Childrens Res Inst, Neonatal Res, Parkville, Vic, Australia
[11] Univ Melbourne, Dept Paediat, Melbourne, Vic, Australia
[12] Royal Childrens Hosp, Neonatol, Parkville, Vic, Australia
[13] UCL, Dept Med Phys & Biomed Engn, London, England
[14] Middlesex Univ, Dept Nat Sci, London, England
基金
英国医学研究理事会;
关键词
EIT; electrical impedance; respiratory system; electrode rotation; electrode spacing; neonatal lung imaging; EIT belt; electrodes; positive end-expiratory pressure; LUNG-VOLUME; REGIONAL VENTILATION; SUSTAINED INFLATION; EIT; PRETERM; TIME; RECRUITMENT; PRESSURE; POSITION; INFANTS;
D O I
10.1088/1361-6579/ab7b42
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objective: Non-adhesive textile electrode belts offer several advantages over adhesive electrodes and are increasingly used in neonatal patients during continuous electrical impedance tomography (EIT) lung monitoring. However, non-adhesive belts may rotate in unsedated patients and discrepancies between chest circumference and belt sizes may result in a gap between electrodes near the sternum. This project aimed to determine the effects of belt rotation and sternal electrode gap on commonly used lung EIT parameters. Approach: We developed a simulation framework based on a 3D finite-element model and introduced lung regions with little or no ventilation that could be changed according to a decremental positive end-expiratory pressure (PEEP) trial. Four degrees of sternal gap and belt rotation were simulated and their effect on the EIT parameters silent spaces, centre of ventilation, global inhomogeneity index and overdistension/collapsed lung (OD/CL) analysed. Additionally, seven premature infants were examined to assess the influence of leftward and rightward belt rotations in a clinical setting. Main results: Small violations of the electrode equidistance criterion and rotations of the belts less than one electrode space exert only minor effects on the EIT parameters and do not impede the interpretation. Rotations of two and three electrode spaces induce non-negligible effects that might lead to flawed interpretations. The 'best PEEP' determined with the OD/CL approach was robust and identifiable with all studied sternal gaps and belt rotations.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Effect of Electrode Gel Application Between Patient's Skin and Electrode Belt on Electrical Impedance Tomography of the Thorax
    Buzkova, Kristyna
    Albrechtova, Denisa
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 81 - 85
  • [2] Optimum design of electrode structure and parameters in electrical impedance tomography
    Yan, W
    Hong, S
    Chaoshi, R
    PHYSIOLOGICAL MEASUREMENT, 2006, 27 (03) : 291 - 306
  • [3] The Effect of Electrode Belt Size Selection upon Evaluation of the Distribution of Ventilation Using Electrical Impedance Tomography
    Buzkova, Kristyna
    Roubik, Karel
    2015 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2015,
  • [4] Performance evaluation of electrode design and material for a large animal electrical impedance tomography belt
    Brabant, Olivia
    Loroesch, Sarah
    Adler, Andy
    Waldmann, Andreas D.
    Raisis, Anthea
    Mosing, Martina
    VETERINARY RECORD, 2022, 191 (12) : no
  • [5] Electrode models in electrical impedance tomography
    WANG M. (Institute of Particle Science and Engineering
    Journal of Zhejiang University Science A(Science in Engineering), 2005, (12) : 1386 - 1393
  • [6] A novel method for diaphragm-based electrode belt position of electrical impedance tomography by ultrasound
    Yue, Chaofu
    He, Huaiwu
    Su, Longxiang
    Wang, Jun
    Yuan, Siyi
    Long, Yun
    Zhao, Zhanqi
    JOURNAL OF INTENSIVE CARE, 2023, 11 (01):
  • [7] A novel method for diaphragm-based electrode belt position of electrical impedance tomography by ultrasound
    Chaofu Yue
    Huaiwu He
    Longxiang Su
    Jun Wang
    Siyi Yuan
    Yun Long
    Zhanqi Zhao
    Journal of Intensive Care, 11 (1)
  • [8] Effect of electrode arrangements on bladder volume estimation by electrical impedance tomography
    Schlebusch, Thomas
    Leonhardt, Steffen
    XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434
  • [9] Effect of Electrode Belt and Body Positions on Regional Pulmonary Ventilation- and Perfusion-Related Impedance Changes Measured by Electric Impedance Tomography
    Ericsson, Elin
    Tesselaar, Erik
    Sjoberg, Folke
    PLOS ONE, 2016, 11 (06):
  • [10] ELECTRODE MODELING IN ELECTRICAL-IMPEDANCE TOMOGRAPHY
    PAULSON, K
    BRECKON, W
    PIDCOCK, M
    SIAM JOURNAL ON APPLIED MATHEMATICS, 1992, 52 (04) : 1012 - 1022