3.0-T high-field magnetic resonance imaging of the female pelvis: preliminary experiences

被引:37
|
作者
Morakkabati-Spitz, N [1 ]
Gieseke, J [1 ]
Kuhl, C [1 ]
Lutterbey, G [1 ]
von Falkenhausen, M [1 ]
Traeber, F [1 ]
Zivanovic, O [1 ]
Schild, HH [1 ]
机构
[1] Univ Bonn, Dept Radiol, D-53105 Bonn, Germany
关键词
pelvis; high-fieldmagnetic resonance imaging; 3.0; T;
D O I
10.1007/s00330-004-2589-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The-purpose of this study was to evaluate if 3.0 T allows for clinically useful pelvic magnetic resonance imaging, i.e. if familiar image quality and tissue contrast can be achieved at 3.0 T as compared with at 1.5 T. Adapting a 1.5-T protocol to the 3.0-T environment is subject to a variety of factors. In order to reduce the number of potential variables, we chose two cornerstones: the 3.0-T sequence should have similar spatial resolution and acquisition time; furthermore, the contrast parameters repetition time (TR) and echo time (TE) were kept identical. Based on this modified 3.0-T T2-weighted turbo spin-echo sequence (TR/TE 2,705/80 ms; 0.7x1.04x4 mm measured voxel size; field of view 360 mm; 4.03-min scan time) we performed an intraindividual study on 19 patients with the 1.5-T sequence as the standard of reference. Two radiologists analyzed the examinations in consensus with regard to tissue contrast (visualization of zonal anatomy of the uterus and/or delineation of pathologic findings) rated on a three-point scale (3 is 3.0 T better; 2 is 3.0 T equal; I is 3.0 T worse than 1.5 T). In addition, the signal difference between muscle and bone marrow was measured as a marker for tissue contrast. The analysis of the image quality comprised the level of the artifacts (rated on a five-point scale: I is no artifacts; 5 is nondiagnostic study), the visual signal-to-noise ratio (rated on a three-point scale) and detail delineation. Only minor artifacts were observed at both 1.5 and 3.0 T; the difference was not statistically significant. The visual signal-to-noise ratio and the delineation of image details were rated equal for 1.5 and 3.0 T. With regard to image contrast, both qualitative analysis as well as quantitative analysis revealed comparable image contrast for the 1.5- and 3.0-T protocols. Pathological findings were seen equally well with both field strengths. Clinically diagnostic pelvic studies of high image quality can be obtained using a 3.0-T scanner with our modified examination protocol. To fully exploit the capability of the high-field technique, and to point out potential advantages, further intraindividual studies are needed, with the adjustment of other imaging parameters to the high-field environment.
引用
收藏
页码:639 / 644
页数:6
相关论文
共 50 条
  • [41] High-Field Optical Cesium Magnetometer for Magnetic Resonance Imaging
    Staerkind, Hans
    Jensen, Kasper
    Muller, Jorg H.
    Boer, Vincent O.
    Polzik, Eugene S.
    Petersen, Esben T.
    PRX QUANTUM, 2024, 5 (02):
  • [42] Ultra High-Field Magnetic Resonance Imaging of a Glaucoma Microstent
    Allemann, Reto
    Langner, Soenke
    Witt, Martin
    Schmidt, Wolfram
    Schmitz, Klaus-Peter
    Hosten, Norbert
    Guthoff, Rudolf
    Stachs, Oliver
    CURRENT EYE RESEARCH, 2011, 36 (08) : 719 - 726
  • [43] High-field magnetic resonance imaging of the human temporal lobe
    Colon-Perez, Luis M.
    King, Michael
    Parekh, Mansi
    Boutzoukas, Angelique
    Carmona, Eduardo
    Couret, Michelle
    Klassen, Rosemary
    Mareci, Thomas H.
    Carney, Paul R.
    NEUROIMAGE-CLINICAL, 2015, 9 : 58 - 68
  • [44] The Correlation Between Diffusion-Weighted Imaging at 3.0-T Magnetic Resonance Imaging and Histopathology for Pancreatic Ductal Adenocarcinoma
    Xie, Ping
    Liu, Kefu
    Peng, Weijun
    Zhou, Zhengrong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (05) : 697 - 701
  • [45] Effect of 1.5-T and 3.0-T magnetic resonance imaging on the ceramic adhesion and physical properties of prosthetic substructures
    Baysal, Nurten
    Ayyildiz, Simel
    Orujalipoor, Ilghar
    Erol, Baris Filiz
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : 809.e1 - 809.e7
  • [46] MAGNETIC-RESONANCE-IMAGING OF THE ABNORMAL FEMALE PELVIS
    BUTHIAU, D
    YVART, J
    IDY, I
    BITTOUN, J
    DARBOIS, Y
    HEITZ, P
    DESGREZ, A
    ANNALES DE RADIOLOGIE, 1987, 30 (04) : 245 - 254
  • [47] A Study on the Development of a Phase Array Coil for MRI of a Mouse in a 3.0-T High Magnetic Field
    Goo, Eun-Hoe
    Lee, Jae-Seung
    Kim, Moon-Jib
    Kweon, Dae-Cheol
    Dong, Kyung-Rae
    Chung, Woon-Kwan
    Lee, Jin-Kook
    Jang, Keun-Jo
    Lim, Jong-Deuk
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (04) : 2855 - 2860
  • [48] MAGNETIC-RESONANCE-IMAGING OF THE NORMAL FEMALE PELVIS
    MCCARTHY, S
    RADIOLOGIC CLINICS OF NORTH AMERICA, 1992, 30 (04) : 769 - 775
  • [49] MAGNETIC-RESONANCE IMAGING OF THE ABNORMAL FEMALE PELVIS
    BUTHIAU, D
    YVART, J
    IDY, I
    BITTOUN, J
    DARBOIS, Y
    HEITZ, P
    DESGREZ, A
    SEMAINE DES HOPITAUX, 1987, 63 (47-48): : 3675 - 3684
  • [50] MAGNETIC-RESONANCE IMAGING OF THE NORMAL FEMALE PELVIS
    SNOEP, G
    VANENGELSHOVEN, JMA
    FALKE, THM
    PLANTES, BGZD
    WILLEBRAND, D
    DEHAAN, J
    DIAGNOSTIC IMAGING IN CLINICAL MEDICINE, 1985, 54 (02) : 57 - 63