3.0-T high-field magnetic resonance imaging of the female pelvis: preliminary experiences

被引:37
|
作者
Morakkabati-Spitz, N [1 ]
Gieseke, J [1 ]
Kuhl, C [1 ]
Lutterbey, G [1 ]
von Falkenhausen, M [1 ]
Traeber, F [1 ]
Zivanovic, O [1 ]
Schild, HH [1 ]
机构
[1] Univ Bonn, Dept Radiol, D-53105 Bonn, Germany
关键词
pelvis; high-fieldmagnetic resonance imaging; 3.0; T;
D O I
10.1007/s00330-004-2589-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The-purpose of this study was to evaluate if 3.0 T allows for clinically useful pelvic magnetic resonance imaging, i.e. if familiar image quality and tissue contrast can be achieved at 3.0 T as compared with at 1.5 T. Adapting a 1.5-T protocol to the 3.0-T environment is subject to a variety of factors. In order to reduce the number of potential variables, we chose two cornerstones: the 3.0-T sequence should have similar spatial resolution and acquisition time; furthermore, the contrast parameters repetition time (TR) and echo time (TE) were kept identical. Based on this modified 3.0-T T2-weighted turbo spin-echo sequence (TR/TE 2,705/80 ms; 0.7x1.04x4 mm measured voxel size; field of view 360 mm; 4.03-min scan time) we performed an intraindividual study on 19 patients with the 1.5-T sequence as the standard of reference. Two radiologists analyzed the examinations in consensus with regard to tissue contrast (visualization of zonal anatomy of the uterus and/or delineation of pathologic findings) rated on a three-point scale (3 is 3.0 T better; 2 is 3.0 T equal; I is 3.0 T worse than 1.5 T). In addition, the signal difference between muscle and bone marrow was measured as a marker for tissue contrast. The analysis of the image quality comprised the level of the artifacts (rated on a five-point scale: I is no artifacts; 5 is nondiagnostic study), the visual signal-to-noise ratio (rated on a three-point scale) and detail delineation. Only minor artifacts were observed at both 1.5 and 3.0 T; the difference was not statistically significant. The visual signal-to-noise ratio and the delineation of image details were rated equal for 1.5 and 3.0 T. With regard to image contrast, both qualitative analysis as well as quantitative analysis revealed comparable image contrast for the 1.5- and 3.0-T protocols. Pathological findings were seen equally well with both field strengths. Clinically diagnostic pelvic studies of high image quality can be obtained using a 3.0-T scanner with our modified examination protocol. To fully exploit the capability of the high-field technique, and to point out potential advantages, further intraindividual studies are needed, with the adjustment of other imaging parameters to the high-field environment.
引用
收藏
页码:639 / 644
页数:6
相关论文
共 50 条
  • [21] Superconducting array for high-field magnetic resonance imaging
    Wosik, J.
    Xue, L.
    Xie, L.-M.
    Kamel, M. R.
    Nesteruk, K.
    Bankson, James A.
    APPLIED PHYSICS LETTERS, 2007, 91 (18)
  • [22] High-Field Atherosclerotic Plaque Magnetic Resonance Imaging
    Yuan, Chun
    Wang, Jinnan
    Balu, Niranjan
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2012, 22 (02) : 271 - +
  • [23] Amyloid Imaging Using High-Field Magnetic Resonance
    Amatsubo, Tomone
    Yanagisawa, Daijiro
    Morikawa, Shigehiro
    Taguchi, Hiroyasu
    Tooyama, Ikuo
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2010, 9 (03) : 95 - 99
  • [24] Apparent Diffusion Coefficients of Normal Uterus in Premenopausal Women With 3.0-T Magnetic Resonance Imaging
    Kuang, Fei
    Ren, Jing
    Huan, Yi
    Chen, Ziqian
    Zhong, Qun
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2012, 36 (01) : 54 - 59
  • [25] MAGNETIC-RESONANCE-IMAGING OF THE FEMALE PELVIS
    PICUS, D
    LEE, JKT
    UROLOGIC RADIOLOGY, 1986, 8 (03) : 166 - 174
  • [26] Use of high-resolution 3.0-T magnetic resonance imaging to characterize atherosclerotic plaques in patients with cerebral infarction
    Xu, Peng
    Lv, Lulu
    Li, Shaodong
    Ge, Haitao
    Rong, Yutao
    Hu, Chunfeng
    Xu, Kai
    EXPERIMENTAL AND THERAPEUTIC MEDICINE, 2015, 10 (06) : 2424 - 2428
  • [27] Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Pancreatic Ductal Adenocarcinoma at 3.0-T Magnetic Resonance: Correlation With Histopathology
    Liu, Kefu
    Xie, Ping
    Peng, Weijun
    Zhou, Zhengrong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (01) : 13 - 18
  • [28] Application of 3.0T intraoperative high-field magnetic resonance imaging guidance for the surgery of arteriovenous malformation within eloquent areas
    Zhu Fengping
    Tian Yanlong
    Zhu Wei
    Gu Yuxiang
    Xu Bin
    Wu Jinsong
    Mao Ying
    Zhou Liangfu
    CHINESE MEDICAL JOURNAL, 2014, 127 (06) : 1180 - 1182
  • [29] Application of 3.0T intraoperative high-field magnetic resonance imaging guidance for the surgery of arteriovenous malformation within eloquent areas
    Zhu Fengping
    Tian Yanlong
    Zhu Wei
    Gu Yuxiang
    Xu Bin
    Wu Jinsong
    Mao Ying
    Zhou Liangfu
    中华医学杂志(英文版), 2014, 127 (06) : 1180 - 1182
  • [30] Dynamic contrast-enhanced imaging of the wrist in rheumatoid arthritis: dedicated low-field (0.25-T) versus high-field (3.0-T) MRI
    Lee, Ryan K. L.
    Griffith, James F.
    Wang, D. F.
    Shi, L.
    Yeung, David K. W.
    Li, Edmund K.
    Tam, L. S.
    SKELETAL RADIOLOGY, 2015, 44 (08) : 1095 - 1101