3.0-T high-field magnetic resonance imaging of the female pelvis: preliminary experiences

被引:37
|
作者
Morakkabati-Spitz, N [1 ]
Gieseke, J [1 ]
Kuhl, C [1 ]
Lutterbey, G [1 ]
von Falkenhausen, M [1 ]
Traeber, F [1 ]
Zivanovic, O [1 ]
Schild, HH [1 ]
机构
[1] Univ Bonn, Dept Radiol, D-53105 Bonn, Germany
关键词
pelvis; high-fieldmagnetic resonance imaging; 3.0; T;
D O I
10.1007/s00330-004-2589-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The-purpose of this study was to evaluate if 3.0 T allows for clinically useful pelvic magnetic resonance imaging, i.e. if familiar image quality and tissue contrast can be achieved at 3.0 T as compared with at 1.5 T. Adapting a 1.5-T protocol to the 3.0-T environment is subject to a variety of factors. In order to reduce the number of potential variables, we chose two cornerstones: the 3.0-T sequence should have similar spatial resolution and acquisition time; furthermore, the contrast parameters repetition time (TR) and echo time (TE) were kept identical. Based on this modified 3.0-T T2-weighted turbo spin-echo sequence (TR/TE 2,705/80 ms; 0.7x1.04x4 mm measured voxel size; field of view 360 mm; 4.03-min scan time) we performed an intraindividual study on 19 patients with the 1.5-T sequence as the standard of reference. Two radiologists analyzed the examinations in consensus with regard to tissue contrast (visualization of zonal anatomy of the uterus and/or delineation of pathologic findings) rated on a three-point scale (3 is 3.0 T better; 2 is 3.0 T equal; I is 3.0 T worse than 1.5 T). In addition, the signal difference between muscle and bone marrow was measured as a marker for tissue contrast. The analysis of the image quality comprised the level of the artifacts (rated on a five-point scale: I is no artifacts; 5 is nondiagnostic study), the visual signal-to-noise ratio (rated on a three-point scale) and detail delineation. Only minor artifacts were observed at both 1.5 and 3.0 T; the difference was not statistically significant. The visual signal-to-noise ratio and the delineation of image details were rated equal for 1.5 and 3.0 T. With regard to image contrast, both qualitative analysis as well as quantitative analysis revealed comparable image contrast for the 1.5- and 3.0-T protocols. Pathological findings were seen equally well with both field strengths. Clinically diagnostic pelvic studies of high image quality can be obtained using a 3.0-T scanner with our modified examination protocol. To fully exploit the capability of the high-field technique, and to point out potential advantages, further intraindividual studies are needed, with the adjustment of other imaging parameters to the high-field environment.
引用
收藏
页码:639 / 644
页数:6
相关论文
共 50 条
  • [31] Association of 3.0-T Brain Magnetic Resonance Imaging Biomarkers With Cognitive Function in the Dallas Heart Study
    Gupta, Mohit
    King, Kevin S.
    Srinivasa, Rajiv
    Weiner, Myron F.
    Hulsey, Keith
    Ayers, Colby R.
    Whittemore, Anthony
    McColl, Roderick W.
    Rossetti, Heidi C.
    Peshock, Ronald M.
    JAMA NEUROLOGY, 2015, 72 (02) : 170 - 175
  • [32] Unexpectedly Smaller Artifacts of 3.0-T Magnetic Resonance Imaging than 1.5 T: Recommendation of 3.0-T Scanners for Patients with Magnet-Resistant Adjustable Ventriculoperitoneal Shunt Devices
    Amano, Yuki
    Kuroda, Naoto
    Uchida, Daiki
    Sakakura, Yuya
    Nakatogawa, Hirokazu
    Ando, Naoto
    Nakayama, Teiji
    Sato, Haruhiko
    Masui, Takayuki
    Sameshima, Tetsuro
    Tanaka, Tokutaro
    WORLD NEUROSURGERY, 2019, 130 : E393 - E399
  • [33] Dynamic contrast-enhanced imaging of the wrist in rheumatoid arthritis: dedicated low-field (0.25-T) versus high-field (3.0-T) MRI
    Ryan K. L. Lee
    James F. Griffith
    D. F. Wang
    L. Shi
    David K. W. Yeung
    Edmund K. Li
    L. S. Tam
    Skeletal Radiology, 2015, 44 : 1095 - 1101
  • [34] High-field magnetic resonance imaging in patients with moyamoya disease
    Harada, A
    Fujii, Y
    Yoneoka, Y
    Takeuchi, S
    Tanaka, R
    Nakada, T
    JOURNAL OF NEUROSURGERY, 2001, 94 (02) : 233 - 237
  • [35] HIGH-FIELD MAGNETIC-RESONANCE IMAGING OF INTRACRANIAL HEMATOMAS
    GOMORI, JM
    GROSSMAN, RI
    STEINER, I
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1988, 24 (4-5): : 218 - 223
  • [36] MAGNETIC-RESONANCE IMAGING OF THE BREAST AT HIGH-FIELD STRENGTH
    HERON, CW
    WILLIAMS, MP
    CHERRYMAN, GR
    HUSBAND, JE
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (728): : 762 - 762
  • [37] Stepped Impedance Resonators for High-Field Magnetic Resonance Imaging
    Akgun, Can E.
    DelaBarre, Lance
    Yoo, Hyoungsuk
    Sohn, Sung-Min
    Snyder, Carl J.
    Adriany, Gregor
    Ugurbil, Kamil
    Gopinath, Anand
    Vaughan, J. Thomas
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (02) : 327 - 333
  • [38] How to implement high-field intraoperative magnetic resonance imaging
    Nimsky, C
    Ganslandt, O
    Fahlbusch, R
    CARS 2002: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2002, : 139 - 143
  • [39] HIGH-FIELD MAGNETIC-RESONANCE-IMAGING OF THE RECTOSIGMOID COLON
    GREENBAUM, D
    SIERRA, A
    FOSTER, K
    LYONS, J
    POTCHEN, E
    GASTROENTEROLOGY, 1986, 90 (05) : 1437 - 1437
  • [40] Ceramic dielectric resonators for high-field magnetic resonance imaging
    Tyagi, Varun
    Semouchkina, Elena
    Lanagan, Michael
    Baker, Amanda
    Webb, Andrew
    Neuberger, Thomas
    2007 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM, VOLS 1-12, 2007, : 3903 - +