3.0-T high-field magnetic resonance imaging of the female pelvis: preliminary experiences

被引:37
|
作者
Morakkabati-Spitz, N [1 ]
Gieseke, J [1 ]
Kuhl, C [1 ]
Lutterbey, G [1 ]
von Falkenhausen, M [1 ]
Traeber, F [1 ]
Zivanovic, O [1 ]
Schild, HH [1 ]
机构
[1] Univ Bonn, Dept Radiol, D-53105 Bonn, Germany
关键词
pelvis; high-fieldmagnetic resonance imaging; 3.0; T;
D O I
10.1007/s00330-004-2589-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The-purpose of this study was to evaluate if 3.0 T allows for clinically useful pelvic magnetic resonance imaging, i.e. if familiar image quality and tissue contrast can be achieved at 3.0 T as compared with at 1.5 T. Adapting a 1.5-T protocol to the 3.0-T environment is subject to a variety of factors. In order to reduce the number of potential variables, we chose two cornerstones: the 3.0-T sequence should have similar spatial resolution and acquisition time; furthermore, the contrast parameters repetition time (TR) and echo time (TE) were kept identical. Based on this modified 3.0-T T2-weighted turbo spin-echo sequence (TR/TE 2,705/80 ms; 0.7x1.04x4 mm measured voxel size; field of view 360 mm; 4.03-min scan time) we performed an intraindividual study on 19 patients with the 1.5-T sequence as the standard of reference. Two radiologists analyzed the examinations in consensus with regard to tissue contrast (visualization of zonal anatomy of the uterus and/or delineation of pathologic findings) rated on a three-point scale (3 is 3.0 T better; 2 is 3.0 T equal; I is 3.0 T worse than 1.5 T). In addition, the signal difference between muscle and bone marrow was measured as a marker for tissue contrast. The analysis of the image quality comprised the level of the artifacts (rated on a five-point scale: I is no artifacts; 5 is nondiagnostic study), the visual signal-to-noise ratio (rated on a three-point scale) and detail delineation. Only minor artifacts were observed at both 1.5 and 3.0 T; the difference was not statistically significant. The visual signal-to-noise ratio and the delineation of image details were rated equal for 1.5 and 3.0 T. With regard to image contrast, both qualitative analysis as well as quantitative analysis revealed comparable image contrast for the 1.5- and 3.0-T protocols. Pathological findings were seen equally well with both field strengths. Clinically diagnostic pelvic studies of high image quality can be obtained using a 3.0-T scanner with our modified examination protocol. To fully exploit the capability of the high-field technique, and to point out potential advantages, further intraindividual studies are needed, with the adjustment of other imaging parameters to the high-field environment.
引用
收藏
页码:639 / 644
页数:6
相关论文
共 50 条
  • [1] 3.0-T high-field magnetic resonance imaging of the female pelvis: preliminary experiences
    N. Morakkabati-Spitz
    J. Gieseke
    C. Kuhl
    G. Lutterbey
    M. von Falkenhausen
    F. Traeber
    O. Zivanovic
    H. H. Schild
    European Radiology, 2005, 15 : 639 - 644
  • [2] Perineural invasion detected by high-field 3.0-T magnetic resonance imaging
    Penn, Renee
    Abemayor, Elliot
    Nabili, Vishad
    Bhuta, Sunita
    Kirsch, Claudia
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2010, 31 (06) : 482 - 484
  • [3] A preliminary study of 3.0-T magnetic resonance diffusion tensor imaging in cervical spondylotic myelopathy
    Fulong Dong
    Yuanyuan Wu
    Peiwen Song
    Yinfeng Qian
    Ying Wang
    Liyan Xu
    Minmin Yin
    Renjie Zhang
    Hui Tao
    Peng Ge
    Chang Liu
    Huaqing Zhang
    Jinwen Zhu
    Cailiang Shen
    Yongqiang Yu
    European Spine Journal, 2018, 27 : 1839 - 1845
  • [4] A preliminary study of 3.0-T magnetic resonance diffusion tensor imaging in cervical spondylotic myelopathy
    Dong, Fulong
    Wu, Yuanyuan
    Song, Peiwen
    Qian, Yinfeng
    Wang, Ying
    Xu, Liyan
    Yin, Minmin
    Zhang, Renjie
    Tao, Hui
    Ge, Peng
    Liu, Chang
    Zhang, Huaqing
    Zhu, Jinwen
    Shen, Cailiang
    Yu, Yongqiang
    EUROPEAN SPINE JOURNAL, 2018, 27 (08) : 1839 - 1845
  • [5] High Resolution Magnetic Resonance Imaging Anatomy of the Ankle and the Foot Ligaments on a 3.0-T Magnet
    Rao, A. T.
    Stanton, D.
    Krampert, S.
    Kramer, L. A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [6] High-Field Magnetic Resonance Imaging
    Kangarlu, Alayar
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2009, 19 (01) : 113 - +
  • [7] Needle Heating During Interventional Magnetic Resonance Imaging at 1.5-and 3.0-T Field Strengths
    Khodarahmi, Iman
    Bonham, Luke W.
    Weiss, Clifford R.
    Fritz, Jan
    INVESTIGATIVE RADIOLOGY, 2020, 55 (06) : 396 - 404
  • [9] 3.0-T magnetic resonance imaging in children with brachial plexus birth injury
    Pan, Shinong
    Tian, Lijie
    Liao, Wei
    Tian, Feng
    Mao, Jian
    Wang, Fei
    Bai, Rongjie
    Li, Qi
    Chen, Zhian
    Guo, Qiyong
    NEURAL REGENERATION RESEARCH, 2011, 6 (06) : 474 - 480
  • [10] Inflammation High-Field Magnetic Resonance Imaging
    Kilsdonk, Iris D.
    de Graaf, Wolter L.
    Barkhof, Frederik
    Wattjes, Mike P.
    NEUROIMAGING CLINICS OF NORTH AMERICA, 2012, 22 (02) : 135 - +