Dosimetric comparison of integral dose for different techniques of craniospinal irradiation

被引:3
|
作者
Goswami, Brijesh [1 ,2 ]
Jain, Rakesh Kumar [2 ]
Yadav, Suresh [3 ]
Kumar, Sunil [1 ]
Oommen, Saji [1 ]
Manocha, Sapna [1 ]
Jadav, Genesh K. [1 ]
机构
[1] Indraprastha Apollo Hosp, Dept Radiotherapy, New Delhi 110076, India
[2] Shobhit Inst Engn & Technol, Dept Phys, Meerut 250110, Uttar Pradesh, India
[3] Gandhi Med Coll, Dept Radiotherapy, Bhopal, Madhya Pradesh, India
关键词
craniospinal irradiation; helical; integral dose; intensity-modulated radiotherapy; RapidArc; three-dimensional conformal radiation therapy; VOLUMETRIC MODULATED ARC; HELICAL TOMOTHERAPY; RADIATION-THERAPY; CONFORMAL RADIOTHERAPY; FEASIBILITY; TOMODIRECT; RAPIDARC;
D O I
10.1017/S1460396920000424
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: Comparison of the integral dose (ID) delivered to organs at risk (OAR), non-target body and target body by using different techniques of craniospinal irradiation (CSI). Materials and methods: Ten CSI patients (medulloblastoma) already planned and treated either with linear accelerator three-dimensional conformal radiation therapy (Linac-3DCRT) technique or with linear accelerator RapidArc (Linac-RapidArc) technique by Novalis-Tx Linac machine have been analysed. Retrospectively, these patients are again planned on Radixact-X9 Linac with Helical, Direct-3DCRT and Direct-intensity-modulated radiation therapy (Direct-IMRT) techniques. The dose prescription to planning target volume brain (PTV-Brain) and PTV-Spine is 36 Gy in 20 fractions and is kept the same for all techniques. The target body, non-target body, OARs and total body dose are compared. Results: ID is lowest in the RapidArc plan for every patient in comparison to Helical and Direct-IMRT. The ID for Body-PTV was found slightly higher in the RapidArc plan in comparison to 3DCRT plans. But there is better normal tissue sparing for most of the OARs in RapidArc plans if it compares with 3DCRT plans. Findings: RapidArc is a better alternative for the treatment of CSI. It provides better target coverage and better OARs sparing from any other treatment techniques.
引用
收藏
页码:345 / 350
页数:6
相关论文
共 50 条
  • [41] Dosimetric Evaluation of Knowledge - Based Therapy Planning for Complex Craniospinal Irradiation
    Anchineyan, P.
    Amal, J.
    Arulin, D.
    Amutham, R.
    Gurunath, K.
    Sridhar, P. S.
    Kumar, B. Ajai
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E524 - E525
  • [42] Craniospinal irradiation in Helical Tomotherapy: Dosimetric analysis and acute toxicity evaluation
    Malukar, Siddharth
    Parikh, Ankita
    Kunikullaya, Suryanarayana
    Rath, Satyajeet
    Singh, Jayesh
    Pandya, Akash
    Dash, Niranjan
    Arun, T.
    Mehta, Maitrik
    Shah, Sonal Patel
    Shivhare, Vinay
    Yadav, Rajan
    Patel, Dhara
    Prajapati, Krishna
    Hadiya, Piyush
    Bopche, Tushar
    Pelagade, Satish
    Kakkad, Mitul
    Jincy, C. D.
    Pachat, Anagha
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S959 - S962
  • [43] Dosimetric comparison of four different external beams for breast irradiation
    Yoon Hee Lee
    Weon Kuu Chung
    Dong Wook Kim
    Oh Young Kwon
    Journal of the Korean Physical Society, 2017, 70 : 300 - 307
  • [44] Dosimetric Comparison of Four Different External Beams for Breast Irradiation
    Lee, Yoon Hee
    Chung, Weon Kuu
    Kim, Dong Wook
    Kwon, Oh Young
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2017, 70 (03) : 300 - 307
  • [45] Dosimetric Predictors of Acute Lymphopenia during Proton Craniospinal Irradiation in Children
    Cordova, J. S.
    Huang, J.
    Perkins, S. M.
    Badiyan, S. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (03): : E478 - E479
  • [46] Dosimetric comparison of radiation techniques in the irradiation of the supraclavicular fossa in breast cancer
    Ahmed, M.
    King, D.
    Barron, S.
    Quigley, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S64 - S65
  • [47] Pediatric craniospinal irradiation with conventional technique or helical tomotherapy: impact of age and body volume on integral dose
    Barra, Salvina
    Gusinu, Marco
    Timon, Giorgia
    Giannelli, Flavio
    Vidano, Giulia
    Garre, Maria Luisa
    Corvo, Renzo
    TUMORI JOURNAL, 2016, 102 (04): : 387 - 392
  • [48] Prospective study on dosimetric comparison of helical tomotherapy and 3DCRT for craniospinal irradiation - A single institution experience
    Bandurska-Luque, Anna
    Piotrowski, Tomasz
    Skrobala, Agnieszka
    Ryczkowski, Adam
    Adamska, Krystyna
    Kazmierska, Joanna
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (02) : 145 - 152
  • [49] Dosimetric comparison between single IMRT field and multiple IMRT fields technique for use in craniospinal irradiation (CSI)
    Barhoum, Suliman
    Sasaki, David
    Brechin, Pam
    McCurdy, Boyd
    MEDICAL PHYSICS, 2017, 44 (08) : 4389 - 4389
  • [50] Craniospinal Irradiation: A Dosimetric Comparison Between O-Ring Linac and Conventional C-arm Linac
    Stroubinis, Theodoros
    Psarras, Michalis
    Zygogianni, Anna
    Protopapa, Maria
    Kouloulias, Vassilis
    Platoni, Kalliopi
    ADVANCES IN RADIATION ONCOLOGY, 2023, 8 (02)