Dosimetric comparison of integral dose for different techniques of craniospinal irradiation

被引:3
|
作者
Goswami, Brijesh [1 ,2 ]
Jain, Rakesh Kumar [2 ]
Yadav, Suresh [3 ]
Kumar, Sunil [1 ]
Oommen, Saji [1 ]
Manocha, Sapna [1 ]
Jadav, Genesh K. [1 ]
机构
[1] Indraprastha Apollo Hosp, Dept Radiotherapy, New Delhi 110076, India
[2] Shobhit Inst Engn & Technol, Dept Phys, Meerut 250110, Uttar Pradesh, India
[3] Gandhi Med Coll, Dept Radiotherapy, Bhopal, Madhya Pradesh, India
关键词
craniospinal irradiation; helical; integral dose; intensity-modulated radiotherapy; RapidArc; three-dimensional conformal radiation therapy; VOLUMETRIC MODULATED ARC; HELICAL TOMOTHERAPY; RADIATION-THERAPY; CONFORMAL RADIOTHERAPY; FEASIBILITY; TOMODIRECT; RAPIDARC;
D O I
10.1017/S1460396920000424
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Aim: Comparison of the integral dose (ID) delivered to organs at risk (OAR), non-target body and target body by using different techniques of craniospinal irradiation (CSI). Materials and methods: Ten CSI patients (medulloblastoma) already planned and treated either with linear accelerator three-dimensional conformal radiation therapy (Linac-3DCRT) technique or with linear accelerator RapidArc (Linac-RapidArc) technique by Novalis-Tx Linac machine have been analysed. Retrospectively, these patients are again planned on Radixact-X9 Linac with Helical, Direct-3DCRT and Direct-intensity-modulated radiation therapy (Direct-IMRT) techniques. The dose prescription to planning target volume brain (PTV-Brain) and PTV-Spine is 36 Gy in 20 fractions and is kept the same for all techniques. The target body, non-target body, OARs and total body dose are compared. Results: ID is lowest in the RapidArc plan for every patient in comparison to Helical and Direct-IMRT. The ID for Body-PTV was found slightly higher in the RapidArc plan in comparison to 3DCRT plans. But there is better normal tissue sparing for most of the OARs in RapidArc plans if it compares with 3DCRT plans. Findings: RapidArc is a better alternative for the treatment of CSI. It provides better target coverage and better OARs sparing from any other treatment techniques.
引用
收藏
页码:345 / 350
页数:6
相关论文
共 50 条
  • [31] Dosimetric Evaluation of the Dose Calculation Accuracy of Different Algorithms for Two Different Treatment Techniques During Whole Breast Irradiation
    Pacaci, P.
    Cebe, M.
    Mabhouti, H.
    Codel, G.
    Serin, E.
    Sanli, E.
    Kucukmorkoc, E.
    Doyuran, M.
    Kucuk, N.
    Canoglu, D.
    Altinok, A.
    Acar, H.
    Ozkok, H. Caglar
    MEDICAL PHYSICS, 2016, 43 (06) : 3351 - 3351
  • [32] Clinical and dosimetric issues of VMAT craniospinal irradiation for paediatric medulloblastoma
    Meroni, S.
    Giandini, T.
    Diletto, B.
    Pecori, E.
    Chiruzzi, C.
    Biassoni, V.
    Schiavello, E.
    Sreafico, F.
    Massimino, M.
    Pignoli, E.
    Gandola, L.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S408 - S408
  • [33] Dosimetric Comparison and Plan Evaluation of Different Dose Computing Algorithms for Different Radiotherapy Techniques in Head and Neck Tumors
    Pandu B.
    Khanna D.
    Mohandass P.
    Elavarasan R.
    Vivek T.R.
    Jacob S.
    Sunny G.
    Ninan H.
    Maddipati T.
    Iranian Journal of Medical Physics, 2022, 19 (06) : 346 - 355
  • [34] Three-Dimensional Conformal Radiation Therapy, Volumetric Intensity Modulated Arc Therapy, and Helical Tomotherapy for Pediatric Craniospinal Irradiation: Dosimetric Analysis of Integral Dose
    Achari, R. Basu
    Gowardhanan, D.
    Arun, B.
    Dharmendran, P.
    Prasath, S.
    Chatterjee, S.
    Mallick, I.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S591 - S592
  • [35] Pediatric craniospinal irradiation with a short partial-arc VMAT technique for medulloblastoma tumors in dosimetric comparison
    Gerhard Pollul
    Tilman Bostel
    Sascha Grossmann
    Sati Akbaba
    Heiko Karle
    Marcus Stockinger
    Heinz Schmidberger
    Radiation Oncology, 15
  • [36] Pediatric craniospinal irradiation with a short partial-arc VMAT technique for medulloblastoma tumors in dosimetric comparison
    Pollul, Gerhard
    Bostel, Tilman
    Grossmann, Sascha
    Akbaba, Sati
    Karle, Heiko
    Stockinger, Marcus
    Schmidberger, Heinz
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [37] Dosimetric comparison of three different radiotherapy techniques (3DCRT, ECOMP & VMAT) for breast irradiation
    Trivedi, G.
    Oinam, A. S.
    Yadav, B. Singh
    Vasudeva, T.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (02): : 371 - 379
  • [38] Dosimetric comparison of different radiotherapy techniques for the treatment of Retinoblastoma
    Nath, Jyotiman
    Goswami, Pranjal
    Medhi, Partha Pratim
    Sarma, Gautam
    Kalita, Apurba Kumar
    Bhattacharyya, Mouchumee
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (02) : 159 - 164
  • [39] Quantitative Estimation of Integral Doses and Skin Entry Exit Doses during Different Radiation Treatment Delivery Techniques for Craniospinal Irradiation Patients
    Devi, Rama
    Basandrai, Deepak
    Passi, Kamlesh
    Iranian Journal of Medical Physics, 2024, 21 (03) : 147 - 153
  • [40] Out-of-Field dose in craniospinal irradiation
    Jalbout, W.
    Howell, R.
    Newhauser, W.
    Geara, F.
    Khater, N.
    Taddei, P.
    MEDICAL PHYSICS, 2012, 39 (07) : 4631 - 4631