3D transcranial ultrasound as a novel intra-operative imaging technique for DBS surgery: a feasibility study

被引:8
|
作者
Ahmadi, Seyed-Ahmad [1 ]
Milletari, Fausto [2 ]
Navab, Nassir [2 ]
Schuberth, Madeleine [1 ]
Plate, Annika [1 ]
Boetzel, Kai [1 ]
机构
[1] LMU Klinikum Grosshadern, Dept Neurol, Munich, Germany
[2] Tech Univ Munich, CAMP, D-80290 Munich, Germany
关键词
New intra-operative sensors; Ultrasound; Magnetic resonance imaging; Neurosurgery; Deep brain stimulation; DEEP BRAIN-STIMULATION; GLOBUS-PALLIDUS INTERNUS; SUBSTANTIA-NIGRA; REGISTRATION; NEUROSURGERY; PLACEMENT; DIAGNOSIS; DISEASE; RISK;
D O I
10.1007/s11548-015-1191-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intra-operative image guidance during deep brain stimulation (DBS) surgery is usually avoided due to cost and overhead of intra-operative MRI and CT acquisitions. Recently, there has been interest in the community towards the usage of non-invasive transcranial ultrasound (TCUS) through the preauricular bone window. In this work, we investigate, for the first time, the feasibility of using 3D-TCUS for imaging of already implanted DBS electrodes. As a first step towards this goal, we report imaging methods and electrode localisation errors outside of the operating room on eight previously operated DBS patients. We evaluate the feasibility of using 3D-TCUS by registering volumes to pre-operative T1-MRI. US-MRI registration is achieved through a two-step point-based approach. First, a rough surface scan of the subjects' skin surface in 3D-TCUS space is registered to a segmented skin-surface point cloud from MRI. Next, we perform a refinement using rigid registration of multiple pairs of manually marked anatomical landmarks. We validate against post-operative CT scans which are also registered to pre-operative MRI. Qualitative results are given in form of 3D reconstruction examples at 2.5 and 3.5 MHz TCUS image frequency, overlaid on pre-operative T1-MRI and post-operative CT. Quantitative evaluation is performed by reporting the accuracy of electrode tip localisation at 2.5 and 3.5 MHz after our US-MRI approach. As a baseline, we also report RMSE errors for pairs of anatomical landmarks in pre-operative MRI and 3D-TCUS. Multiple image examples show the appearance and quality of 3D-TCUS scans, depending on the bone window. Overall accuracy of anatomic point pairs lies on the order of 3.2 mm, using our registration approach. Compared to this baseline, electrode tip localisation in 3D-TCUS has a mean accuracy on the order of 4.8 mm and a precision on the order of 2.3 mm. While insufficient at first glance, we argue why these results are promising nonetheless. Our work motivates further future work in improved TCUS scanning, advanced TCUS-MRI registration and computer-aided electrode detection in 3D-TCUS.
引用
收藏
页码:891 / 900
页数:10
相关论文
共 50 条
  • [1] 3D transcranial ultrasound as a novel intra-operative imaging technique for DBS surgery: a feasibility study
    Seyed-Ahmad Ahmadi
    Fausto Milletari
    Nassir Navab
    Madeleine Schuberth
    Annika Plate
    Kai Bötzel
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 891 - 900
  • [2] Intra-operative Imaging with 3D Ultrasound in Neurosurgery
    Unsgard, Geirmund
    Solheim, Ole
    Lindseth, Frank
    Selbekk, Tormod
    INTRAOPERATIVE IMAGING, 2011, 109 : 181 - 186
  • [3] Intra-operative 3D ultrasound in neurosurgery
    Unsgaard, G
    Rygh, OM
    Selbekk, T
    Müller, TB
    Kolstad, F
    Lindseth, F
    Hernes, TAN
    ACTA NEUROCHIRURGICA, 2006, 148 (03) : 235 - 253
  • [4] Intra-operative 3D ultrasound in neurosurgery
    G. Unsgaard
    O. M. Rygh
    T. Selbekk
    T. B. Müller
    F. Kolstad
    F. Lindseth
    T. A. Nagelhus Hernes
    Acta Neurochirurgica, 2006, 148 : 235 - 253
  • [5] Intra-operative 3D ultrasound in neurosurgery
    Unsgaard, G.
    PROCEEDINGS OF THE 13TH EUROPEAN CONGRESS OF NEUROSURGERY, 2007, : 25 - 30
  • [6] Intra-operative 3D ultrasound augmentation
    Aylward, SR
    Jomier, J
    Guyon, JP
    Weeks, S
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 421 - 424
  • [7] Interest of intra-operative 3D imaging in spine surgery: a prospective randomized study
    Sébastien Ruatti
    C. Dubois
    E. Chipon
    G. Kerschbaumer
    M. Milaire
    A. Moreau-Gaudry
    J. Tonetti
    Ph. Merloz
    European Spine Journal, 2016, 25 : 1738 - 1744
  • [8] Interest of intra-operative 3D imaging in spine surgery: a prospective randomized study
    Ruatti, Sebastien
    Dubois, C.
    Chipon, E.
    Kerschbaumer, G.
    Milaire, M.
    Moreau-Gaudry, A.
    Tonetti, J.
    Merloz, Ph.
    EUROPEAN SPINE JOURNAL, 2016, 25 (06) : 1738 - 1744
  • [9] Intra-operative 3D ultrasound in neurosurgery - Comment
    Doczi, T
    ACTA NEUROCHIRURGICA, 2006, 148 (03) : 253 - 253
  • [10] Vascular image registration for intra-operative 3D ultrasound annotation
    Jomier, J
    Weeks, S
    Aylward, SR
    CARS 2004: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2004, 1268 : 1308 - 1308