3D transcranial ultrasound as a novel intra-operative imaging technique for DBS surgery: a feasibility study

被引:8
|
作者
Ahmadi, Seyed-Ahmad [1 ]
Milletari, Fausto [2 ]
Navab, Nassir [2 ]
Schuberth, Madeleine [1 ]
Plate, Annika [1 ]
Boetzel, Kai [1 ]
机构
[1] LMU Klinikum Grosshadern, Dept Neurol, Munich, Germany
[2] Tech Univ Munich, CAMP, D-80290 Munich, Germany
关键词
New intra-operative sensors; Ultrasound; Magnetic resonance imaging; Neurosurgery; Deep brain stimulation; DEEP BRAIN-STIMULATION; GLOBUS-PALLIDUS INTERNUS; SUBSTANTIA-NIGRA; REGISTRATION; NEUROSURGERY; PLACEMENT; DIAGNOSIS; DISEASE; RISK;
D O I
10.1007/s11548-015-1191-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intra-operative image guidance during deep brain stimulation (DBS) surgery is usually avoided due to cost and overhead of intra-operative MRI and CT acquisitions. Recently, there has been interest in the community towards the usage of non-invasive transcranial ultrasound (TCUS) through the preauricular bone window. In this work, we investigate, for the first time, the feasibility of using 3D-TCUS for imaging of already implanted DBS electrodes. As a first step towards this goal, we report imaging methods and electrode localisation errors outside of the operating room on eight previously operated DBS patients. We evaluate the feasibility of using 3D-TCUS by registering volumes to pre-operative T1-MRI. US-MRI registration is achieved through a two-step point-based approach. First, a rough surface scan of the subjects' skin surface in 3D-TCUS space is registered to a segmented skin-surface point cloud from MRI. Next, we perform a refinement using rigid registration of multiple pairs of manually marked anatomical landmarks. We validate against post-operative CT scans which are also registered to pre-operative MRI. Qualitative results are given in form of 3D reconstruction examples at 2.5 and 3.5 MHz TCUS image frequency, overlaid on pre-operative T1-MRI and post-operative CT. Quantitative evaluation is performed by reporting the accuracy of electrode tip localisation at 2.5 and 3.5 MHz after our US-MRI approach. As a baseline, we also report RMSE errors for pairs of anatomical landmarks in pre-operative MRI and 3D-TCUS. Multiple image examples show the appearance and quality of 3D-TCUS scans, depending on the bone window. Overall accuracy of anatomic point pairs lies on the order of 3.2 mm, using our registration approach. Compared to this baseline, electrode tip localisation in 3D-TCUS has a mean accuracy on the order of 4.8 mm and a precision on the order of 2.3 mm. While insufficient at first glance, we argue why these results are promising nonetheless. Our work motivates further future work in improved TCUS scanning, advanced TCUS-MRI registration and computer-aided electrode detection in 3D-TCUS.
引用
收藏
页码:891 / 900
页数:10
相关论文
共 50 条
  • [21] Needle and seed segmentation in intra-operative 3D ultrasound-guided prostate brachytherapy
    Ding, Mingyue
    Wei, Zhouping
    Gardi, Lori
    Downey, Donal B.
    Fenster, Aaron
    ULTRASONICS, 2006, 44 : E331 - E336
  • [22] Effects of intra-operative fluoroscopic 3D-imaging on peri-operative imaging strategy in calcaneal fracture surgery
    M. S. H. Beerekamp
    M. Backes
    N. W. L. Schep
    D. T. Ubbink
    J. S. Luitse
    T. Schepers
    J. C. Goslings
    Archives of Orthopaedic and Trauma Surgery, 2017, 137 : 1667 - 1675
  • [23] Effects of intra-operative fluoroscopic 3D-imaging on peri-operative imaging strategy in calcaneal fracture surgery
    Beerekamp, M. S. H.
    Backes, M.
    Schep, N. W. L.
    Ubbink, D. T.
    Luitse, J. S.
    Schepers, T.
    Goslings, J. C.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2017, 137 (12) : 1667 - 1675
  • [24] Registration of pre-operative 3D medical image and intra-operative 3D laparoscopic image
    Nomura, T
    Okamoto, R
    Kataoka, H
    Hata, N
    Masamune, K
    Suzuki, M
    Dohi, T
    CAR '98 - COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1998, 1165 : 922 - 922
  • [25] 1D-3D Registration for Intra-Operative Nuclear Imaging in Radio-Guided Surgery
    Vetter, Christoph
    Lasser, Tobias
    Okur, Asli
    Navab, Nassir
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) : 608 - 617
  • [26] Biomechanically Driven Registration of Pre- to Intra-Operative 3D Images for Laparoscopic Surgery
    Oktay, Ozan
    Zhang, Li
    Mansi, Tommaso
    Mountney, Peter
    Mewes, Philip
    Nicolau, Stephane
    Soler, Luc
    Chefd'hotel, Christophe
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2013, PT II, 2013, 8150 : 1 - 9
  • [27] Evaluation of intra-operative ultrasound imaging in brain tumor resection: a prospective study
    Renner, C
    Lindner, D
    Schneider, JP
    Meixensberger, J
    NEUROLOGICAL RESEARCH, 2005, 27 (04) : 351 - 357
  • [28] 3D ultrasound navigation in syrinx surgery - a feasibility study
    Bonsanto, MM
    Metzner, R
    Aschoff, A
    Tronnier, V
    Kunze, S
    Wirtz, CR
    ACTA NEUROCHIRURGICA, 2005, 147 (05) : 533 - 541
  • [29] 3D ultrasound navigation in syrinx surgery – a feasibility study
    M. M. Bonsanto
    R. Metzner
    A. Aschoff
    V. Tronnier
    S. Kunze
    C. R. Wirtz
    Acta Neurochirurgica, 2005, 147 : 533 - 541
  • [30] Automatic brain structure-guided registration of pre and intra-operative 3D ultrasound for neurosurgery
    Ghose, Soumya
    Mills, David M.
    Mitra, Jhimli
    Smith, L. Scott
    Yeo, Desmond T. B.
    Golby, Alexandra J.
    Frisken, Sarah F.
    Foo, Thomas F.
    MEDICAL IMAGING 2020: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2021, 11315