Interest of intra-operative 3D imaging in spine surgery: a prospective randomized study

被引:17
|
作者
Ruatti, Sebastien [1 ]
Dubois, C. [2 ]
Chipon, E. [3 ]
Kerschbaumer, G. [1 ]
Milaire, M. [1 ]
Moreau-Gaudry, A. [3 ]
Tonetti, J. [1 ]
Merloz, Ph. [1 ]
机构
[1] CHU A Michallon, Univ Dept Orthopaed Surg & Traumatol, F-38043 Grenoble, France
[2] CHU A Michallon, Univ Dept Med Imaging, F-38043 Grenoble, France
[3] Univ Grenoble 1, Clin Invest & Technol Innovat Ctr CIC IT, F-38043 Grenoble, France
关键词
Spine surgery; 3D imaging; Computer-aided surgery; Navigation and spine surgery; 3D fluoroscope; PEDICLE SCREW PLACEMENT; COMPUTED-TOMOGRAPHY; NAVIGATION SYSTEM; LUMBAR SPINE; IN-VIVO; ACCURACY; FLUOROSCOPY; INSERTION; GUIDANCE; EXPOSURE;
D O I
10.1007/s00586-015-4141-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We report a single-center, prospective, randomized study for pedicle screw insertion in opened and percutaneous spine surgeries, using a computer-assisted surgery (CAS) technique with three-dimensional (3D) intra-operative images intensifier (without planification on pre-operative CT scan) vs conventional surgical procedure. We included 143 patients: Group C (conventional, 72 patients) and Group N (3D Fluoronavigation, 71 patients). We measured the pedicle screw running time, and surgeon's radiation exposure. All pedicle runs were assessed according to Heary by two independent radiologists on a post-operative CT scan. 3D Fluoronavigation appeared less accurate in percutaneous procedures (24 % of misplaced pedicle screws vs 5 % in Group C) (p = 0.007), but more accurate in opened surgeries (5 % of misplaced pedicle screws vs 17 % in Group C) (p = 0.025). For one vertebra, the average surgical running time reached 8 min in Group C vs 21 min in Group N for percutaneous surgeries (p = 3.42 x 10(-9)), 7.33 min in Group C vs 16.33 min in Group N (p = 2.88 x 10(-7)) for opened surgeries. The 3D navigation device delivered less radiation in percutaneous procedures [0.6 vs 1.62 mSv in Group C (p = 2.45 x 10(-9))]. For opened surgeries, it was twice higher in Group N with 0.21 vs 0.1 mSv in Group C (p = 0.022). The rate of misplaced pedicle screws with conventional techniques was nearly the same as most papers and a little bit higher with CAS. Surgical running time and radiation exposure were consistent with many studies. Our work hypothesis is partially confirmed, depending on the type of surgery (opened or closed procedure).
引用
收藏
页码:1738 / 1744
页数:7
相关论文
共 50 条
  • [1] Interest of intra-operative 3D imaging in spine surgery: a prospective randomized study
    Sébastien Ruatti
    C. Dubois
    E. Chipon
    G. Kerschbaumer
    M. Milaire
    A. Moreau-Gaudry
    J. Tonetti
    Ph. Merloz
    European Spine Journal, 2016, 25 : 1738 - 1744
  • [2] Intra-operative Imaging with 3D Ultrasound in Neurosurgery
    Unsgard, Geirmund
    Solheim, Ole
    Lindseth, Frank
    Selbekk, Tormod
    INTRAOPERATIVE IMAGING, 2011, 109 : 181 - 186
  • [3] 3D transcranial ultrasound as a novel intra-operative imaging technique for DBS surgery: a feasibility study
    Ahmadi, Seyed-Ahmad
    Milletari, Fausto
    Navab, Nassir
    Schuberth, Madeleine
    Plate, Annika
    Boetzel, Kai
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2015, 10 (06) : 891 - 900
  • [4] 3D transcranial ultrasound as a novel intra-operative imaging technique for DBS surgery: a feasibility study
    Seyed-Ahmad Ahmadi
    Fausto Milletari
    Nassir Navab
    Madeleine Schuberth
    Annika Plate
    Kai Bötzel
    International Journal of Computer Assisted Radiology and Surgery, 2015, 10 : 891 - 900
  • [5] Intra-operative 3D ultrasound in neurosurgery
    Unsgaard, G
    Rygh, OM
    Selbekk, T
    Müller, TB
    Kolstad, F
    Lindseth, F
    Hernes, TAN
    ACTA NEUROCHIRURGICA, 2006, 148 (03) : 235 - 253
  • [6] Intra-operative 3D ultrasound in neurosurgery
    G. Unsgaard
    O. M. Rygh
    T. Selbekk
    T. B. Müller
    F. Kolstad
    F. Lindseth
    T. A. Nagelhus Hernes
    Acta Neurochirurgica, 2006, 148 : 235 - 253
  • [7] Intra-operative 3D ultrasound in neurosurgery
    Unsgaard, G.
    PROCEEDINGS OF THE 13TH EUROPEAN CONGRESS OF NEUROSURGERY, 2007, : 25 - 30
  • [8] Intra-operative 3D ultrasound augmentation
    Aylward, SR
    Jomier, J
    Guyon, JP
    Weeks, S
    2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 421 - 424
  • [9] Intra-operative imaging in trauma surgery
    Keil, Holger
    Beisemann, Nils
    Swartman, Benedict
    Vetter, Sven Yves
    Gruezner, Paul Alfred
    Franke, Jochen
    EFORT OPEN REVIEWS, 2018, 3 (10): : 541 - 549
  • [10] Intra-operative 3D ultrasound in neurosurgery - Comment
    Doczi, T
    ACTA NEUROCHIRURGICA, 2006, 148 (03) : 253 - 253