Beyond flux: Total corneal oxygen consumption as an index of corneal oxygenation during contact lens wear

被引:62
|
作者
Brennan, NA [1 ]
机构
[1] Brennan Consultants, Auburn Village 3122, Australia
关键词
cornea; contact lens; oxygen transmissibility; oxygen consumption; silicone-hydrogel;
D O I
10.1097/01.opx.0000168560.10861.ae
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of this study is to compute total corneal oxygen consumption during contact lens wear and consider the concept as an index for describing corneal oxygenation during contact lens wear as opposed to flux, partial pressure, or Dk/t. Method. Estimates of total corneal oxygen consumption were generated using a previously described eight-layer model based on oxygen diffusion equations and using contemporary estimates of tear and corneal layer thicknesses. Relative consumption, expressed as %Q (percentage of normal consumption without contact lens wear), was also calculated for daily wear and continuous wear modes, thereby providing an index of the chronic hypoxic effect of contact lens wear. Results. Corneal oxygen consumption is calculated to converge to the same value of 44.8 nL/cm(3)/sec above a Dk/t of approximately 20 and 300 x 10(-9) (cm/sec)(mL0(2)/mL/mm Hg) for the open and closed eye scenarios, respectively. Lenses with Dk/t values of 15 and 50 x 10(-9) (cm/sec)(mL0(2)/mL/mm Hg) allow about 96% of normal long-term total oxygen consumption without a contact lens in place for daily wear and continuous wear, respectively. Conclusion. Total corneal oxygen consumption is based on physical parameters, represents a direct index of corneal oxygen metabolism and thus cellular energy (ATP) production, allows direct comparison between two lenses or a lens and nonlens-wearing state, and eliminates the ambiguity of other measures, thereby providing an attractive means of describing corneal oxygenation.
引用
收藏
页码:467 / 472
页数:6
相关论文
共 50 条
  • [41] Infectious keratitis with corneal perforation associated with corneal hydrops and contact lens wear in keratoconus
    Donnenfeld, ED
    Schrier, A
    Perry, HD
    Ingraham, HJ
    Lasonde, R
    Epstein, A
    Farber, B
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (05) : 409 - 412
  • [42] Corneal relaxation time estimation as a function of tear oxygen tension in human cornea during contact lens wear
    Felipe Del Castillo, Luis
    Ramirez-Calderon, Juanibeth G.
    Del Castillo, Roxana M.
    Aguilella-Arzo, Marcel
    Compan, Vicente
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2020, 108 (01) : 14 - 21
  • [43] STUDIES ON CORNEAL NEOVASCULARIZATION AT THE SOFT CONTACT-LENS WEAR
    KOHRI, C
    FOLIA OPHTHALMOLOGICA JAPONICA, 1979, 30 (01): : 154 - 163
  • [44] Effect of contact lens wear on central corneal thickness measurements
    Braun, DA
    Penno, EEA
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (07): : 1319 - 1322
  • [45] CHANGES IN CORNEAL CURVATURE ASSOCIATED WITH CONTACT-LENS WEAR
    RENGSTORFF, RH
    JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 1979, 50 (03) : 375 - 377
  • [46] CORNEAL THICKNESS CHANGES WITH EXTENDED CONTACT-LENS WEAR
    SCHOESSLER, JP
    BARR, JT
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1980, 57 (10): : 729 - 733
  • [47] The effect of contact lens wear on the central and peripheral corneal endothelium
    Wiffen, SJ
    Hodge, DO
    Bourne, WM
    CORNEA, 2000, 19 (01) : 47 - 51
  • [48] Effect of contact lens wear on the anatomic values of the corneal thickness
    Sanchis-Gimeno, J. A.
    Herrera, M.
    Rahhal, M. S.
    Martinez-Soriano, F.
    EUROPEAN JOURNAL OF ANATOMY, 2007, 11 (03) : 181 - 184
  • [49] THE EFFECT OF AGE AND CONTACT LENS WEAR ON CORNEAL LANGERHANS CELLS
    Golebiowski, Blanka
    Bui, Kim
    Lam, Winnie
    Chao, Cecilia
    Richdale, Kathryn
    Stapleton, Fiona
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [50] PATTERNS OF CORNEAL DISTORTION ASSOCIATED WITH CONTACT-LENS WEAR
    STEVENSON, RWW
    KIRKNESS, CM
    DAMATO, B
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1993, 34 (04) : 1007 - 1007