Beyond flux: Total corneal oxygen consumption as an index of corneal oxygenation during contact lens wear

被引:62
|
作者
Brennan, NA [1 ]
机构
[1] Brennan Consultants, Auburn Village 3122, Australia
关键词
cornea; contact lens; oxygen transmissibility; oxygen consumption; silicone-hydrogel;
D O I
10.1097/01.opx.0000168560.10861.ae
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of this study is to compute total corneal oxygen consumption during contact lens wear and consider the concept as an index for describing corneal oxygenation during contact lens wear as opposed to flux, partial pressure, or Dk/t. Method. Estimates of total corneal oxygen consumption were generated using a previously described eight-layer model based on oxygen diffusion equations and using contemporary estimates of tear and corneal layer thicknesses. Relative consumption, expressed as %Q (percentage of normal consumption without contact lens wear), was also calculated for daily wear and continuous wear modes, thereby providing an index of the chronic hypoxic effect of contact lens wear. Results. Corneal oxygen consumption is calculated to converge to the same value of 44.8 nL/cm(3)/sec above a Dk/t of approximately 20 and 300 x 10(-9) (cm/sec)(mL0(2)/mL/mm Hg) for the open and closed eye scenarios, respectively. Lenses with Dk/t values of 15 and 50 x 10(-9) (cm/sec)(mL0(2)/mL/mm Hg) allow about 96% of normal long-term total oxygen consumption without a contact lens in place for daily wear and continuous wear, respectively. Conclusion. Total corneal oxygen consumption is based on physical parameters, represents a direct index of corneal oxygen metabolism and thus cellular energy (ATP) production, allows direct comparison between two lenses or a lens and nonlens-wearing state, and eliminates the ambiguity of other measures, thereby providing an attractive means of describing corneal oxygenation.
引用
收藏
页码:467 / 472
页数:6
相关论文
共 50 条
  • [21] RIGID CONTACT-LENS AREA AND CORNEAL OXYGENATION
    MANDELL, RB
    KANG, L
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1988, 65 (05): : 387 - 394
  • [22] Diffusion and Monod Kinetics to Determine In Vivo Human Corneal Oxygen-Consumption Rate During Soft Contact-Lens Wear
    Chhabra, Mahendra
    Prausnitz, John M.
    Radke, C. J.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 90B (01) : 202 - 209
  • [23] OXYGEN REQUIREMENTS OF CORNEAL CONTACT LENS SYSTEMS
    CUKLANZ, HD
    HILL, RM
    AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1968, 45 (10): : 680 - &
  • [24] CORNEAL RESPONSE TO RIGID CONTACT-LENS WEAR
    BERGMANSON, JPG
    CHU, LWF
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1982, 66 (10) : 667 - 675
  • [25] CORNEAL DELLEN - FOLLOWING CONTACT-LENS WEAR
    ROSENBERY, S
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1969, 67 (06) : 970 - +
  • [26] CORNEAL STAINING RELATING TO CONTACT-LENS WEAR
    KLINE, LN
    DELUCA, TJ
    FISHBERG, GM
    JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 1979, 50 (03) : 353 - 357
  • [27] CORNEAL ULCERS ASSOCIATED WITH CONTACT-LENS WEAR
    GALENTINE, PG
    COHEN, EJ
    LAIBSON, PR
    ADAMS, CP
    MICHAUD, R
    ARENTSEN, JJ
    ARCHIVES OF OPHTHALMOLOGY, 1984, 102 (06) : 891 - 894
  • [28] Corneal Response to Scleral Contact Lens Wear in Keratoconus
    Cagliari, Cristina
    Schor, Paulo
    Formentin, Luiz
    Lipener, Cesar
    dos Santos, Myrna Serapiao
    Oliveira, Helena
    de Carvalho Raulino Junior, Jose Ney
    de Freitas, Denise
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (08): : 322 - 327
  • [29] Corneal infiltrates associated with soft contact lens wear
    Baum, J
    Donshik, PC
    CORNEA, 2004, 23 (04) : 421 - 422
  • [30] CONTACT-LENS AND CORNEAL TOPOGRAPHY WITH WEAR OF SOFLENS
    TOMLINSON, A
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1976, 53 (11): : 727 - 734