Beyond flux: Total corneal oxygen consumption as an index of corneal oxygenation during contact lens wear

被引:62
|
作者
Brennan, NA [1 ]
机构
[1] Brennan Consultants, Auburn Village 3122, Australia
关键词
cornea; contact lens; oxygen transmissibility; oxygen consumption; silicone-hydrogel;
D O I
10.1097/01.opx.0000168560.10861.ae
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The purpose of this study is to compute total corneal oxygen consumption during contact lens wear and consider the concept as an index for describing corneal oxygenation during contact lens wear as opposed to flux, partial pressure, or Dk/t. Method. Estimates of total corneal oxygen consumption were generated using a previously described eight-layer model based on oxygen diffusion equations and using contemporary estimates of tear and corneal layer thicknesses. Relative consumption, expressed as %Q (percentage of normal consumption without contact lens wear), was also calculated for daily wear and continuous wear modes, thereby providing an index of the chronic hypoxic effect of contact lens wear. Results. Corneal oxygen consumption is calculated to converge to the same value of 44.8 nL/cm(3)/sec above a Dk/t of approximately 20 and 300 x 10(-9) (cm/sec)(mL0(2)/mL/mm Hg) for the open and closed eye scenarios, respectively. Lenses with Dk/t values of 15 and 50 x 10(-9) (cm/sec)(mL0(2)/mL/mm Hg) allow about 96% of normal long-term total oxygen consumption without a contact lens in place for daily wear and continuous wear, respectively. Conclusion. Total corneal oxygen consumption is based on physical parameters, represents a direct index of corneal oxygen metabolism and thus cellular energy (ATP) production, allows direct comparison between two lenses or a lens and nonlens-wearing state, and eliminates the ambiguity of other measures, thereby providing an attractive means of describing corneal oxygenation.
引用
收藏
页码:467 / 472
页数:6
相关论文
共 50 条
  • [32] Variations in the corneal surface temperature with contact lens wear
    Ooi, E. H.
    Ng, E. Y. K.
    Purslow, C.
    Acharya, R.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H4) : 337 - 349
  • [33] Evaluation of corneal nerve density with contact lens wear
    Putnam, Nicole M.
    Pilcher, Stephanie
    Bowin, David
    Harrison, Wendy Watkins
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [34] Corneal tomographic changes during corneal rigid gas-permeable contact lens wear in keratoconic eyes
    Koh, Shizuka
    Inoue, Ryota
    Maeda, Naoyuki
    Oie, Yoshinori
    Jhanji, Vishal
    Miki, Atsuya
    Nishida, Kohji
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2022, 106 (02) : 197 - 202
  • [35] Corneal inflammation during overnight contact lens wear - Clinical variables.
    Stapleton, F
    Ramachandran, L
    Kumar, S
    Sweeney, DF
    Holden, BA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 660 - 660
  • [36] Central and Peripheral Corneal Thickness Changes during Scleral Contact Lens Wear
    Tse, Vivien
    Kim, Young Hyun
    Lin, Kristina
    Tan, Bo
    Zhou, Yixiu
    Li, Wing
    Lin, Meng C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [37] Corneal epithelial thickness and corneal curvature changes during the day: The effects of daily disposable contact lens wear
    Turhan, Semra Akkaya
    Yigit, Didem Dizdar
    Toker, Ebru
    CONTACT LENS & ANTERIOR EYE, 2020, 43 (04): : 389 - 394
  • [38] Corneal Epithelium Changes during Three Months of Scleral Contact Lens Wear
    Tse, Vivien
    Truong, Tan
    Zhou, Yixiu
    Tan, Bo
    Lin, Kristina
    Lin, Meng C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [39] Assessment of corneal thickness and tear meniscus during contact-lens wear
    Del Aguila-Carrasco, Antonio J.
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Esteve-Taboada, Jose J.
    Montes-Mico, Robert
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (03): : 185 - 193
  • [40] Analysis of the application of the generalized monod kinetics model to describe the human corneal oxygen-consumption rate during soft contact lens wear
    Compan, V.
    Aguilella-Arzo, M.
    Del Castillo, L. F.
    Hernandez, S. I.
    Gonzalez-Meijome, J. M.
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2017, 105 (08) : 2269 - 2281