Bi-planar 2D-to-3D registration in Fourier domain for stereoscopic X-ray motion tracking

被引:0
|
作者
Zosso, Dominique [1 ]
Le Callennec, Benoit [2 ]
Cuadra, Meritxell Bach [1 ]
Aminian, Kamiar [2 ]
Jolles, Brigitte M. [3 ]
Thiran, Jean-Philippe [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Signal Proc Lab, CH-1015 Lausanne, Switzerland
[2] Ecole Polytech Fed Lausanne, Lab Movement Anal & Measurement, CH-1015 Lausanne, Switzerland
[3] Univ Lausanne Hosp, Hosp Orthoped Suisse Romande, Dept Orthopaed, CH-1005 Lausanne, Switzerland
关键词
registration; X-ray; motion analysis;
D O I
10.1117/12.769469
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper we present a new method to track bone movements in stereoscopic X-ray image series of the knee joint. The method is based on two different X-ray image sets: a rotational series of acquisitions of the still subject knee that allows the tomographic reconstruction of the three-dimensional volume (model), and a stereoscopic image series of orthogonal projections as the subject performs movements. Tracking the movements of bones throughout the stereoscopic image series means to determine, for each frame, the best pose of every moving element (bone) previously identified in the 3D reconstructed model. The quality of a pose is reflected in the similarity between its theoretical projections and the actual radiographs. We use direct Fourier reconstruction to approximate the three-dimensional volume of the knee joint. Then, to avoid the expensive computation of digitally rendered radiographs (DRR) for pose recovery, we develop a corollary to the 3-dimensional central-slice theorem and reformulate the tracking problem in the Fourier domain. Under the hypothesis of parallel X-ray beams, the heavy 2D-to-3D registration of projections in the signal domain is replaced by efficient slice-to-volume registration in the Fourier domain. Focusing on rotational movements, the translation-relevant phase information can be discarded and we only consider scalar Fourier amplitudes. The core of our motion tracking algorithm can be implemented as a classical frame-wise slice-to-volume registration task. Results on both synthetic and real images confirm the validity of our approach.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Bundling 3D-and 2D-based registration of MRI to X-ray breast tomosynthesis
    Smole, P. Cotic
    Ruiter, N. V.
    Kaiser, C.
    Krammer, J.
    Hopp, T.
    MEDICAL IMAGING 2018: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2018, 10576
  • [32] Effect of segmentation errors on 3D-to-2D registration of implant models in X-ray images
    Mahfouz, MR
    Hoff, WA
    Komistek, RD
    Dennis, DA
    JOURNAL OF BIOMECHANICS, 2005, 38 (02) : 229 - 239
  • [33] An approach to 2D/3D registration of a vertebra in 2D x-ray fluoroscopies with 3D CT images
    Weese, J
    Buzug, TM
    Lorenz, C
    Fassnacht, C
    CVRMED-MRCAS'97: FIRST JOINT CONFERENCE - COMPUTER VISION, VIRTUAL REALITY AND ROBOTICS IN MEDICINE AND MEDICAL ROBOTICS AND COMPUTER-ASSISTED SURGERY, 1997, 1205 : 119 - 128
  • [34] Gradient-based registration of 3D MR and 2D x-ray images
    Tomazevic, D
    Likar, B
    Pernus, F
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 327 - 332
  • [35] Validation of the relative 3D orientation of vertebrae reconstructed by bi-planar radiography
    Dumas, R
    Le Bras, A
    Champain, N
    Savidan, M
    Mitton, D
    Kalifa, G
    Steib, JP
    de Guise, JA
    Skalli, W
    MEDICAL ENGINEERING & PHYSICS, 2004, 26 (05) : 415 - 422
  • [36] Real-Time 3D Rendering Proces sor for 2D-to-3D Conversion of Stereoscopic Displays
    Lai, Yeong-Kang
    Chung, Yu-Chieh
    2014 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS (ICCE), 2014, : 119 - 120
  • [37] Automatic 3D reconstruction of vertebrae from orthogonal bi-planar radiographs
    Chen, Yuepeng
    Gao, Yue
    Fu, Xiangling
    Chen, Yingyin
    Wu, Ji
    Guo, Chenyi
    Li, Xiaodong
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [38] Self-Supervised 2D/3D Registration for X-Ray to CT Image Fusion
    Jaganathan, Srikrishna
    Kukla, Maximilian
    Wang, Jian
    Shetty, Karthik
    Maier, Andreas
    2023 IEEE/CVF WINTER CONFERENCE ON APPLICATIONS OF COMPUTER VISION (WACV), 2023, : 2787 - 2797
  • [39] Deep learning-based X-ray inpainting for improving spinal 2D-3D registration
    Esfandiari, Hooman
    Weidert, Simon
    Koeveshazi, Istvan
    Anglin, Carolyn
    Street, John
    Hodgson, Antony J.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2021, 17 (02):
  • [40] A fast and robust technique for 3D-2D registration of CT to single plane X-ray fluoroscopy
    Haque, Md. Nazmul
    Pickering, Mark R.
    Al Muhit, Abdullah
    Frater, Michael R.
    Scarvell, Jennie M.
    Smith, Paul N.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2014, 2 (02): : 76 - 89