Validation of the relative 3D orientation of vertebrae reconstructed by bi-planar radiography

被引:20
|
作者
Dumas, R
Le Bras, A
Champain, N
Savidan, M
Mitton, D
Kalifa, G
Steib, JP
de Guise, JA
Skalli, W
机构
[1] ENSAM, CNRS, Lab Biomecan, UMR 8005, F-75013 Paris, France
[2] ETS, CRCHUM, Lab Rech Imagerie & Orthoped, Ctr Rech Chum, Montreal, PQ H2L 4M1, Canada
[3] Hop St Vincent de Paul, F-75674 Paris, France
[4] Hop Univ Strasbourg, Strasbourg, France
关键词
vertebral relative orientation; accuracy; precision; bi-planar radiography; 3D reconstruction;
D O I
10.1016/j.medengphy.2004.02.004
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The three dimensional (3D) reconstruction of the spine can be obtained by stereoradiographic techniques. To be safely used on a routine clinics basis, stereoradiography must provide both accurate vertebral shape and coherent position. Although the accuracy of the reconstructed morphology of the vertebrae is well documented, only few authors studied the accuracy of the vertebral orientation. Therefore, this paper focuses on the evaluation of the orientation accuracy of the reconstructed vertebrae (obtained by non-stereo corresponding point technique) considering either a 178 point vertebral model or a 6 point vertebral model (previously proposed in the literature). Five dried vertebrae were fixed on holders containing four markers each. The 3D reconstruction of both vertebrae and markers were obtained by stereoradiographic techniques. Using least square method matching from one position to another, the relative orientation was computed for the vertebral models (6 or 178 points) and the four markers. These vertebral and holder orientations were compared (considering the holder's one as reference). The repeatability of these relative orientations (vertebrae and holders) was also evaluated. The mean (RMS) orientation error of 178 point vertebral model was 0.6degrees (0.8degrees), for lateral rotation, 0.7degrees (1.0degrees) for sagittal rotation and 1.4degrees (1.9degrees) for axial rotation. The intra-observer repeatability was 0.5degrees (0.7degrees) for lateral rotation, 0.7degrees (0.8degrees) for sagittal rotation and 0.9degrees (1.2degrees) for axial rotation. The orientation was found more accurate and precise when using the 178 point vertebral model than when using the basic 6 point vertebral model. The relative orientation (in post-operative follow-up with respect to the pre-operative examination) of the vertebrae of one scoliotic patient was performed as an example of clinical application. The stereoradiographic method is a reliable 3D quantitative tool to assess the spine deformity, that can be used in clinics for the follow-up of scoliotic patients. (C) 2004 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:415 / 422
页数:8
相关论文
共 50 条
  • [1] Automatic 3D reconstruction of vertebrae from orthogonal bi-planar radiographs
    Chen, Yuepeng
    Gao, Yue
    Fu, Xiangling
    Chen, Yingyin
    Wu, Ji
    Guo, Chenyi
    Li, Xiaodong
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [2] Three-Dimensional (3D) Reconstruction of Dried Vertebrae from Bi-planar Radiographs
    Bennani, Hamza
    McCane, Brendan
    2019 INTERNATIONAL CONFERENCE ON IMAGE AND VISION COMPUTING NEW ZEALAND (IVCNZ), 2019,
  • [3] FOOT LIGAMENTS LENGTH ESTIMATION USING BI-PLANAR RADIOGRAPHY
    ALLARD, P
    DUHAIME, M
    THIRY, PS
    JOURNAL OF BIOMECHANICS, 1982, 15 (04) : 341 - 341
  • [4] 3D pose estimation of fracture femur based on bi-planar digital radiographs
    Zhang, Bin
    Sun, Jinwei
    Sun, Shaobin
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2013, 34 (01): : 140 - 146
  • [5] Calibration of Bi-planar Radiography with a Rangefinder and a Small Calibration Object
    Moura, Daniel C.
    Barbosa, Jorge G.
    Tavares, Joao Lanuel R. S.
    Reis, Ana M.
    ADVANCES IN VISUAL COMPUTING, PT I, PROCEEDINGS, 2008, 5358 : 572 - 581
  • [6] A semi-automated method using interpolation and optimisation for the 3D reconstruction of the spine from bi-planar radiography: a precision and accuracy study
    Dumas, Raphael
    Blanchard, Bertrand
    Carlier, Robert
    de Loubresse, Christian Garreau
    Le Huec, Jean-Charles
    Marty, Catherine
    Moinard, Maryse
    Vital, Jean-Marc
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (01) : 85 - 92
  • [7] A semi-automated method using interpolation and optimisation for the 3D reconstruction of the spine from bi-planar radiography: a precision and accuracy study
    Raphaël Dumas
    Bertrand Blanchard
    Robert Carlier
    Christian Garreau de Loubresse
    Jean-Charles Le Huec
    Catherine Marty
    Maryse Moinard
    Jean-Marc Vital
    Medical & Biological Engineering & Computing, 2008, 46 : 85 - 92
  • [8] Bi-planar spinal stereoradiography of adolescent idiopathic scoliosis: considerations in 3D alignment and functional balance
    Saba Pasha
    Anthony Capraro
    Patrick J. Cahill
    John P. Dormans
    John M. Flynn
    European Spine Journal, 2016, 25 : 3234 - 3241
  • [9] Bi-planar spinal stereoradiography of adolescent idiopathic scoliosis: considerations in 3D alignment and functional balance
    Pasha, Saba
    Capraro, Anthony
    Cahill, Patrick J.
    Dormans, John P.
    Flynn, John M.
    EUROPEAN SPINE JOURNAL, 2016, 25 (10) : 3234 - 3241
  • [10] Water Droplets Translocation and Fission in a 3D Bi-Planar Multifurcated T-Junction Microchannels
    Inn-Leon Lu
    Voon-Loong Wong
    Chin, Jit-Kai
    Kushaari, Kuzilati
    PROCESSES, 2020, 8 (05)