Bi-planar 2D-to-3D registration in Fourier domain for stereoscopic X-ray motion tracking

被引:0
|
作者
Zosso, Dominique [1 ]
Le Callennec, Benoit [2 ]
Cuadra, Meritxell Bach [1 ]
Aminian, Kamiar [2 ]
Jolles, Brigitte M. [3 ]
Thiran, Jean-Philippe [1 ]
机构
[1] Ecole Polytech Fed Lausanne, Signal Proc Lab, CH-1015 Lausanne, Switzerland
[2] Ecole Polytech Fed Lausanne, Lab Movement Anal & Measurement, CH-1015 Lausanne, Switzerland
[3] Univ Lausanne Hosp, Hosp Orthoped Suisse Romande, Dept Orthopaed, CH-1005 Lausanne, Switzerland
关键词
registration; X-ray; motion analysis;
D O I
10.1117/12.769469
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this paper we present a new method to track bone movements in stereoscopic X-ray image series of the knee joint. The method is based on two different X-ray image sets: a rotational series of acquisitions of the still subject knee that allows the tomographic reconstruction of the three-dimensional volume (model), and a stereoscopic image series of orthogonal projections as the subject performs movements. Tracking the movements of bones throughout the stereoscopic image series means to determine, for each frame, the best pose of every moving element (bone) previously identified in the 3D reconstructed model. The quality of a pose is reflected in the similarity between its theoretical projections and the actual radiographs. We use direct Fourier reconstruction to approximate the three-dimensional volume of the knee joint. Then, to avoid the expensive computation of digitally rendered radiographs (DRR) for pose recovery, we develop a corollary to the 3-dimensional central-slice theorem and reformulate the tracking problem in the Fourier domain. Under the hypothesis of parallel X-ray beams, the heavy 2D-to-3D registration of projections in the signal domain is replaced by efficient slice-to-volume registration in the Fourier domain. Focusing on rotational movements, the translation-relevant phase information can be discarded and we only consider scalar Fourier amplitudes. The core of our motion tracking algorithm can be implemented as a classical frame-wise slice-to-volume registration task. Results on both synthetic and real images confirm the validity of our approach.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Spectral-based 2D/3D X-ray to CT image rigid registration
    Freiman, M.
    Pele, O.
    Hurvitz, A.
    Werman, M.
    Joskowicz, L.
    MEDICAL IMAGING 2011: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND MODELING, 2011, 7964
  • [42] 2D/3D Registration for X-ray Guided Bronchoscopy using Distance Map Classification
    Xu, Di
    Xu, Sheng
    Herzka, Daniel A.
    Yung, Rex C.
    Bergtholdt, Martin
    Gutierrez, Luis F.
    McVeigh, Elliot R.
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 3715 - 3718
  • [43] Registration of 3D+t Coronary CTA and Monoplane 2D+t X-Ray Angiography
    Metz, Coert T.
    Schaap, Michiel
    Klein, Stefan
    Baka, Nora
    Neefjes, Lisan A.
    Schultz, Carl J.
    Niessen, Wiro J.
    van Walsum, Theo
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (05) : 919 - 931
  • [44] A HYBIRD OPTIMIZATION APPROACH FOR 2D-3D REGISTRATION-BASED FUSION OF ULTRASOUND AND X-RAY
    Kaiser, Markus
    John, Matthias
    Borsdorf, Anja
    Noettling, Alois
    Neumuth, Thomas
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2013, 58
  • [45] 2D/3D registration based on biplanar X-ray and CT images for surgical navigation
    Yang, Demin
    Shi, Haochen
    Zeng, Bolun
    Chen, Xiaojun
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2024, 257
  • [46] Gradient-based 2-D/3-D rigid registration of fluoroscopic X-ray to CT
    Livyatan, H
    Yaniv, Z
    Joskowicz, L
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2003, 22 (11) : 1395 - 1406
  • [47] 3D Coronary Vessel Tracking in X-Ray Projections
    Poulain, Emmanuelle
    Malandain, Gregoire
    Vaillant, Regis
    FUNCTIONAL IMAGING AND MODELLING OF THE HEART, 2017, 10263 : 204 - 215
  • [48] ARTICULATED REGISTRATION OF 3D HUMAN GEOMETRY TO X-RAY IMAGE
    Le, Sang N.
    Karlekar, Jayashree
    Fang, Anthony C.
    2008 15TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-5, 2008, : 1108 - 1111
  • [49] 3D registration through pseudo x-ray image generation
    Viant, WJ
    Barnel, F
    MEDICINE MEETS VIRTUAL REALITY 2001: OUTER SPACE, INNER SPACE, VIRTUAL SPACE, 2001, 81 : 541 - 543
  • [50] MOTION-BASED DEPTH ESTIMATION FOR 2D-TO-3D VIDEO CONVERSION
    Wang, Ming-Jiun
    Chen, Chun-Fu
    Lee, Gwo Giun
    2013 IEEE INTERNATIONAL CONFERENCE ON VISUAL COMMUNICATIONS AND IMAGE PROCESSING (IEEE VCIP 2013), 2013,