The current study focuses on a non-invasive microwave system based on a UWB antenna for blood glucose measurements in the frequency range of 1-4 GHz. Calculations of the minimal values of microwave reflection coefficient (S11 Min) corresponding to various blood glycemia, as well as comparisons to measured values using the Vector Network Analyzer Anritsu MS46121B, were the major findings of this study. The results were in good agreement, with a shift of less than 5%, demonstrating the effectiveness of our microwave method in detecting blood glycemia. To define an experimental approach between blood and dextrose solution, a comparative study in terms of slops in a linear approximation of both S11 Min and resonant frequency versus glucose concentration for the two mediums was interesting. The deviations in the results are less than 5% in the range of 1-2 GHz. However, it is not the case in the ranges of 2-3 GHz and 3-4 GHz since the two mediums show contrary behavior regarding S11 Min and resonant frequency. Consequently, D-Solution might be used to simulate blood using our system for the investigation of glycemia only in the range of 1-2 GHz.
引用
收藏
页码:712 / 720
页数:9
相关论文
共 50 条
  • [31] Non-Invasive Measurement of Blood Flow Velocity Based on Photoacoustic Calorimetric Measurement
    Xu L.
    Zhang H.
    Li D.
    Chen B.
    Zheng Y.
    Yao L.
    Zhongguo Jiguang/Chinese Journal of Lasers, 2024, 51 (03):
  • [32] Non-Invasive Measurement of Blood Flow Velocity Based on Photoacoustic Calorimetric Measurement
    Xu, Luhan
    Hao, Zhang
    Dong, Li
    Bin, Chen
    Zheng, Yuping
    Yao, Liang
    CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2024, 51 (03):
  • [33] An Antenna Loaded with Complementary Split Ring Resonator for Non-invasive Blood Glucose Measurement
    Lv, Zexiang
    Wang, Junjie
    Li, Gen
    2024 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC 2024, 2024,
  • [34] An Optimized Non-Invasive Blood Glucose and Temperature Body Measurement System
    Ibrahim, Hagar
    Darweesh, M. Saeed
    Soltan, Ahmed
    2022 11TH INTERNATIONAL CONFERENCE ON MODERN CIRCUITS AND SYSTEMS TECHNOLOGIES (MOCAST), 2022,
  • [35] Radio-Frequency and Microwave Techniques for Non-Invasive Measurement of Blood Glucose Levels
    Yilmaz, Tuba
    Foster, Robert
    Hao, Yang
    DIAGNOSTICS, 2019, 9 (01):
  • [36] A novel compact highly sensitive non-invasive microwave antenna sensor for blood glucose monitoring
    Aldhaheri, Rabah W.
    Kamili, Jagadeesh Babu
    Nella, Anveshkumar
    Sobahi, Nebras M.
    OPEN PHYSICS, 2023, 21 (01):
  • [37] Human body model with blood flow properties for non-invasive blood glucose measurement
    Mhatre, Pratik J.
    Joshi, Manjusha
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 72
  • [38] Wearable non-invasive blood glucose monitor system based on galvanic skin resistance measurement
    Donelli, Massimo
    Espa, Giuseppe
    Feraco, Paola
    Manekiya, Mohammedhusen
    ELECTRONICS LETTERS, 2021, 57 (24) : 901 - 902
  • [39] MICROPROCESSOR-BASED SYSTEM FOR NON-INVASIVE MEASUREMENT OF OPTIC DISC BLOOD FLOW.
    Shapiro, Jerrold M.
    Kini, Mohandas M.
    Philpott, Douglas E.
    1978, 17 : 39 - 46
  • [40] Demonstration of Microstrip Sensor for the Feasibility Study of Non-invasive Blood-Glucose Sensing
    Kushal Satish
    Sneh Sen
    MAPAN, 2021, 36 : 193 - 199