Demonstration of Microstrip Sensor for the Feasibility Study of Non-invasive Blood-Glucose Sensing

被引:0
|
作者
Kushal Satish
Sneh Sen
机构
[1] CSIR-National Physical Laboratory,LF, HF Impedance and DC Metrology
[2] Indian Institute of Technology,Department of Textile and Fibre Engineering
[3] Indian Institute of Technology,Centre for Biomedical Engineering
来源
MAPAN | 2021年 / 36卷
关键词
Diabetes; Non-invasive blood glucose measurement; Microwave sensor; Electromagnetic properties; Sensitivity factor;
D O I
暂无
中图分类号
学科分类号
摘要
The present research work is the part of the feasibility study to implement non-invasive blood-glucose sensing using microwave-based sensor. The one-port microstrip patch antenna sensor developed to exhibit variation in its electromagnetic response with respect to blood-glucose level. It has been demonstrated through in vitro controlled experiment under laboratory conditions. The novel multi-parameter-based sensitivity factor termed as GlucoSense was also defined to evaluate the sensitivity of sensor towards the change in glucose concentration. It was established that there was a good correlation between sensor’s reflection properties and glucose concentration. The findings of the controlled experiment convincingly proved that the sensor has the potential to be effectively used for developing a suitable device for non-invasive blood-glucose sensing.
引用
收藏
页码:193 / 199
页数:6
相关论文
共 50 条
  • [1] Demonstration of Microstrip Sensor for the Feasibility Study of Non-invasive Blood-Glucose Sensing
    Satish
    Sen, Kushal
    Anand, Sneh
    MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2021, 36 (01): : 193 - 199
  • [2] Non-Invasive Blood Glucose Sensor: A Feasibility Study
    Lopez Albalat, Alvaro
    Sanz Alaman, Maria Begona
    Dejoz Diez, Maria Cristina
    Martinez-Millana, Antonio
    Traver Salcedo, Vicente
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 1179 - 1182
  • [3] Characterization of an Inter-digitated Sensor for Non-invasive Blood-glucose Sensing
    Satish
    Sen, Kushal
    IETE JOURNAL OF RESEARCH, 2024, 70 (04) : 4203 - 4208
  • [4] A microwave frequency sensor for non-invasive blood-glucose measurement
    Jean, Buford Randall
    Green, Eric C.
    McClung, Melanie J.
    2008 IEEE SENSORS APPLICATIONS SYMPOSIUM, 2008, : 4 - 7
  • [5] Feasibility Study for Non-Invasive Blood Glucose Monitoring
    Freer, Benjamin
    Venkataraman, Jayanti
    2010 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM, 2010,
  • [6] Fundamental study on non-invasive blood glucose sensing
    Xu, Kexin
    Li, Qingbo
    Lu, Zhang
    Jiang, Jingying
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2002, 10 (3-4) : 187 - 197
  • [7] A non-invasive blood glucose detection using a slotted microstrip antenna sensor
    Syamala, Neeli
    Kumar, Bandi Kiran
    Raju, K. Padma
    PHYSICA SCRIPTA, 2024, 99 (06)
  • [8] Development of Non-Invasive Blood-Glucose Measurement System
    Anas, M. N.
    Lim, P. K.
    2013 IEEE INTERNATIONAL CONFERENCE ON SMART INSTRUMENTATION, MEASUREMENT AND APPLICATIONS (ICSIMA 2013), 2013,
  • [9] Derivative Spectroscopy in Non-Invasive Blood-Glucose Analysis
    Dontu, Vishnu
    2016 IEEE FIRST INTERNATIONAL CONFERENCE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE), 2016, : 350 - 351
  • [10] Feasibility study of portable microwave microstrip open-loop resonator for non-invasive blood glucose level sensing: proof of concept
    Carlos G. Juan
    Héctor García
    Ernesto Ávila-Navarro
    Enrique Bronchalo
    Vicente Galiano
    Óscar Moreno
    Domingo Orozco
    José María Sabater-Navarro