Demonstration of Microstrip Sensor for the Feasibility Study of Non-invasive Blood-Glucose Sensing

被引:0
|
作者
Kushal Satish
Sneh Sen
机构
[1] CSIR-National Physical Laboratory,LF, HF Impedance and DC Metrology
[2] Indian Institute of Technology,Department of Textile and Fibre Engineering
[3] Indian Institute of Technology,Centre for Biomedical Engineering
来源
MAPAN | 2021年 / 36卷
关键词
Diabetes; Non-invasive blood glucose measurement; Microwave sensor; Electromagnetic properties; Sensitivity factor;
D O I
暂无
中图分类号
学科分类号
摘要
The present research work is the part of the feasibility study to implement non-invasive blood-glucose sensing using microwave-based sensor. The one-port microstrip patch antenna sensor developed to exhibit variation in its electromagnetic response with respect to blood-glucose level. It has been demonstrated through in vitro controlled experiment under laboratory conditions. The novel multi-parameter-based sensitivity factor termed as GlucoSense was also defined to evaluate the sensitivity of sensor towards the change in glucose concentration. It was established that there was a good correlation between sensor’s reflection properties and glucose concentration. The findings of the controlled experiment convincingly proved that the sensor has the potential to be effectively used for developing a suitable device for non-invasive blood-glucose sensing.
引用
收藏
页码:193 / 199
页数:6
相关论文
共 50 条
  • [31] Non-invasive Blood-Glucose Estimation Using Smartphone PPG Signals and Subspace KNN Classifier
    Zhang, Yuwei
    Zhang, Yuan
    Siddiqui, Sarah Ali
    Kos, Anton
    Elektrotehniski Vestnik/Electrotechnical Review, 2019, 86 (01): : 68 - 74
  • [32] Truly non-invasive glucose optical sensor
    Garcia, Marisol
    Perego, Celine
    Hernandez, Florencio E.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [33] Non-invasive measurement of blood glucose level by time-resolved transmission spectroscopy: A feasibility study
    Sun, Meixiu
    Chen, Nanguang
    OPTICS COMMUNICATIONS, 2012, 285 (06) : 1608 - 1612
  • [34] Evaluation of a guideless non-invasive glucose sensor
    Mattu, Mutua
    Makarawicz, Marcy R.
    Blank, Thomas B.
    Lorenz, Alex D.
    Monfre, Stephen L.
    DIABETES, 2008, 57 : A117 - A117
  • [35] Influence of cholesterol on non-invasive blood glucose sensing studied with NIR spectroscopy
    Jiang, Jingying
    Zhang, Lingling
    Gong, Qiliang
    Xu, Kexin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS VIII, 2011, 7898
  • [36] Discussion on the validity of NIR spectral data in non-invasive blood glucose sensing
    Zhang, Wanjie
    Liu, Rong
    Zhang, Wen
    Jia, Hao
    Xu, Kexin
    BIOMEDICAL OPTICS EXPRESS, 2013, 4 (06): : 789 - 802
  • [37] BLOOD GLUCOSE SENSING THROUGH SKIN BY NON-INVASIVE FINGER TOUCH METER
    Kakkar, T.
    Richards, B.
    Ajjan, R.
    Saha, S.
    Grant, P.
    Jose, G.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2016, 18 : A40 - A40
  • [38] Non-invasive determination of blood glucose level using narrowband microwave sensor
    Deshmukh, Vidya Vijay
    Chorage, Suvarna Sandip
    JOURNAL OF AMBIENT INTELLIGENCE AND HUMANIZED COMPUTING, 2021,
  • [39] Simulation on how to customize glucose adjustment method for non-invasive blood glucose sensing by NIRS
    Min, Xiaolin
    Jiang, Jingying
    Zou, Da
    Liu, Rong
    Xu, Kexin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IX, 2013, 8580
  • [40] Near-infrared LED based Non-invasive Blood Glucose Sensor
    Yadav, Jyoti
    Rani, Asha
    Singh, Vijander
    Murari, Bhaskar Mohan
    2014 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND INTEGRATED NETWORKS (SPIN), 2014, : 591 - 594