A microwave system based on a UWB microstrip antenna for non-invasive in vitro measurement of glycemia in human blood: An experimental study

被引:1
|
作者
El Hassani, Oumaima [1 ]
Saadi, Adil [1 ]
机构
[1] Moulay Ismail Univ, ENSAM Meknes, Control Piloting & Supervis Syst CPSS, Meknes, Morocco
关键词
blood; dextrose-solution; DGS antenna; glycemia; microwave UWB antenna; DIELECTRIC-PROPERTIES; D-GLUCOSE; CONSTANT; TISSUE;
D O I
10.1002/mop.33190
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The current study focuses on a non-invasive microwave system based on a UWB antenna for blood glucose measurements in the frequency range of 1-4 GHz. Calculations of the minimal values of microwave reflection coefficient (S11 Min) corresponding to various blood glycemia, as well as comparisons to measured values using the Vector Network Analyzer Anritsu MS46121B, were the major findings of this study. The results were in good agreement, with a shift of less than 5%, demonstrating the effectiveness of our microwave method in detecting blood glycemia. To define an experimental approach between blood and dextrose solution, a comparative study in terms of slops in a linear approximation of both S11 Min and resonant frequency versus glucose concentration for the two mediums was interesting. The deviations in the results are less than 5% in the range of 1-2 GHz. However, it is not the case in the ranges of 2-3 GHz and 3-4 GHz since the two mediums show contrary behavior regarding S11 Min and resonant frequency. Consequently, D-Solution might be used to simulate blood using our system for the investigation of glycemia only in the range of 1-2 GHz.
引用
收藏
页码:712 / 720
页数:9
相关论文
共 50 条
  • [21] Non-invasive measurement of blood flow in the human lower extremity
    Zhou, Hehe
    Novotny, John E.
    Wang, Liyun
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 561 - 562
  • [22] The System of Indicators of the Continuous Non-Invasive Blood Pressure Measurement
    Timokhov, Gennady, V
    Semenova, Evgeniia A.
    Pivovarov, Vladimir V.
    PROCEEDINGS OF THE 2021 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (ELCONRUS), 2021, : 1860 - 1864
  • [23] A novel system for non-invasive measurement of blood levels of glucose
    Tysoe, Olivia
    NATURE REVIEWS ENDOCRINOLOGY, 2024, 20 (06) : 320 - 320
  • [24] Development of Non-Invasive Blood-Glucose Measurement System
    Anas, M. N.
    Lim, P. K.
    2013 IEEE INTERNATIONAL CONFERENCE ON SMART INSTRUMENTATION, MEASUREMENT AND APPLICATIONS (ICSIMA 2013), 2013,
  • [25] Non-Invasive Measurement of Human Blood Cholesterol Concentration Based on Dynamic Spectrum Method
    Suo Yong-kuan
    Li Gang
    Wang Hui-quan
    Lin Ling
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (01) : 188 - 191
  • [26] Non-invasive Blood Glucose Measurement based on Impedance Spectrum
    Yin, Tong
    Chen, Xiaoyan
    Du, Meng
    Yin, Hongyi
    JOURNAL OF ROBOTICS NETWORKING AND ARTIFICIAL LIFE, 2020, 6 (04): : 246 - 249
  • [27] Application of O2-PLS in experimental study on non-invasive measurement of blood glucose
    Li Y.
    Zhang G.
    Li Q.
    Guangxue Xuebao/Acta Optica Sinica, 2010, 30 (03): : 854 - 860
  • [28] Microwave Non-Invasive Blood Glucose Detection Based on Debye Model
    Hu Min
    Xiao Xia
    Song Hang
    Liu Yu
    LASER & OPTOELECTRONICS PROGRESS, 2020, 57 (23)
  • [29] NON-INVASIVE MEASUREMENT OF HUMAN AORTIC BLOOD-FLOW VELOCITY
    PINARDI, G
    SAINZ, A
    ROBERTS, VC
    ACTA PHYSIOLOGICA LATINOAMERICANA, 1975, 25 : 56 - 56
  • [30] NON-INVASIVE MEASUREMENT OF BLOOD-FLOW IN HUMAN-TUMORS
    EMAMI, B
    NUSSBAUM, GH
    TENHAKEN, RK
    HUGHES, WL
    RADIATION RESEARCH, 1981, 87 (02) : 456 - 456