Out-of-Field Scatter Estimation in 3D Whole body PET

被引:9
|
作者
Iatrou, Maria [1 ]
Manjeshwar, Ravindra M. [1 ]
Wollenweber, Scott D. [2 ]
Ross, Steven G. [2 ]
Stearns, Charles W. [2 ]
机构
[1] GE Res, Niskayuna, NY 12309 USA
[2] GE Healthcare, Waukesha, WI 53188 USA
关键词
D O I
10.1109/NSSMIC.2009.5401923
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Many implementations of model based scatter correction (MBSC) are based on the single scatter simulation (SSS) formulation within the scan field-of-view (FOV). A fully 3D approach that models both the axial and trans-axial scatter components can accurately model scatter from hot regions in neighboring slices and outside the scan FOV resulting in greater quantitative accuracy. Herein we discuss how to incorporate the estimation of out-of-field scatter in fully 3D MBSC.
引用
收藏
页码:3886 / +
页数:2
相关论文
共 50 条
  • [41] 3D Validation of a Monte-Carlo Model of a Cyberknife System Dedicated to the Determination of Out-Of-Field Doses
    Colnot, J.
    Barraux, V.
    Loiseau, C.
    Batalla, A.
    Gschwind, R.
    Huet, C.
    MEDICAL PHYSICS, 2019, 46 (06) : E278 - E279
  • [42] Whole body 3D digitizer (scanner)
    Yokota, K
    SEN-I GAKKAISHI, 1998, 54 (06) : P223 - P226
  • [43] 3D whole body scanners revisited
    Daanen, H. A. M.
    Ter Haar, F. B.
    DISPLAYS, 2013, 34 (04) : 270 - 275
  • [44] Assessment of the quantitation in 3D PET: Influence of out of the field of view radioactive sources
    Ferreira, NC
    Trebossen, R
    Bendriem, B
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1343 - 1347
  • [45] Quantitation of clinical 3D PET studies with the ETM scatter correction
    Trebossen, R
    Bendriem, B
    Fontaine, A
    Rougetet, R
    Frouin, V
    Remy, P
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1447 - 1451
  • [46] Accelerated Monte Carlo Scatter Correction for 3D PET.
    Holdsworth, CH
    Levin, CS
    Dahlbom, M
    Farquhar, TH
    Hoffman, EJ
    JOURNAL OF NUCLEAR MEDICINE, 2000, 41 (05) : 195P - 195P
  • [47] Scatter correction techniques in 3D PET: A Monte Carlo evaluation
    Castiglioni, I
    Cremonesi, O
    Gilardi, MC
    Bettinardi, V
    Rizzo, G
    Savi, A
    Bellotti, E
    Fazio, F
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (06) : 2053 - 2058
  • [48] Analytic correction for scatter in fully 3D PET: Statistical issues
    Ollinger, JM
    1997 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1 & 2, 1998, : 1386 - 1389
  • [49] Evaluation of a Monte Carlo scatter correction in clinical 3D PET
    Holdsworth, CH
    Badawi, RD
    Santos, P
    Van den Abbeele, AD
    Hoffman, EJ
    El Fakhri, G
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2540 - 2544
  • [50] 3D convolutional deep learning for nonlinear estimation of body composition from whole body morphology
    Tian, Isaac Y.
    Liu, Jason
    Wong, Michael C.
    Kelly, Nisa N.
    Liu, Yong E.
    Garber, Andrea K.
    Heymsfield, Steven B.
    Curless, Brian
    Shepherd, John A.
    NPJ DIGITAL MEDICINE, 2025, 8 (01):