Out-of-Field Scatter Estimation in 3D Whole body PET

被引:9
|
作者
Iatrou, Maria [1 ]
Manjeshwar, Ravindra M. [1 ]
Wollenweber, Scott D. [2 ]
Ross, Steven G. [2 ]
Stearns, Charles W. [2 ]
机构
[1] GE Res, Niskayuna, NY 12309 USA
[2] GE Healthcare, Waukesha, WI 53188 USA
关键词
D O I
10.1109/NSSMIC.2009.5401923
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Many implementations of model based scatter correction (MBSC) are based on the single scatter simulation (SSS) formulation within the scan field-of-view (FOV). A fully 3D approach that models both the axial and trans-axial scatter components can accurately model scatter from hot regions in neighboring slices and outside the scan FOV resulting in greater quantitative accuracy. Herein we discuss how to incorporate the estimation of out-of-field scatter in fully 3D MBSC.
引用
收藏
页码:3886 / +
页数:2
相关论文
共 50 条
  • [31] DETECTOR EFFICIENCY AND COMPTON SCATTER IN FULLY 3D PET
    OLLINGER, JM
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1168 - 1173
  • [32] A Comparative Study of Multiple Scatter Estimations in 3D PET
    Qian, Hua
    Manjeshwar, Ravi
    Thielemans, Kris
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2700 - 2702
  • [33] AN INVESTIGATION OF PRACTICAL SCATTER CORRECTION TECHNIQUES FOR 3D PET
    TOWNSEND, DW
    CHOI, Y
    SASHIN, D
    MINTUN, MA
    GROOTOONK, S
    BAILEY, DL
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P50 - P50
  • [34] A method for calibrating 3D PET without scatter correction
    Bailey, DL
    Jones, T
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1046 - 1049
  • [35] Quantifying the effects of defective block detectors in a 3D whole body PET camera
    Samiee, Maryam
    Goertzen, Andrew L.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4258 - 4261
  • [36] Optimization of transmission and emission scan duration in 3D whole-body PET
    Beyer, T
    Kinahan, PE
    Townsend, DW
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) : 2400 - 2407
  • [37] Optimization of transmission and emission scan duration in 3D whole-body PET
    Beyer, T
    Kinahan, PE
    Townsend, DW
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1362 - 1366
  • [38] Dynamic whole body distribution of FBPA in humans studied with 3D PET/CT
    Isohashi, K.
    Kato, H.
    Horitsugi, G.
    Naka, S.
    Mochida, I.
    Shimosegawa, E.
    Hatazawa, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S382 - S383
  • [39] Optimization of transmission and emission scan duration in 3D whole-body PET
    Beyer, Thomas
    Kinahan, Paul E.
    Townsend, David W.
    IEEE Transactions on Nuclear Science, 1997, 44 (6 pt 2): : 2400 - 2407
  • [40] Whole body PET using overlapped 3D acquisition and weighted image summation
    Schubert, SF
    Pajevic, S
    Carson, RE
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1285 - 1289