Out-of-Field Scatter Estimation in 3D Whole body PET

被引:9
|
作者
Iatrou, Maria [1 ]
Manjeshwar, Ravindra M. [1 ]
Wollenweber, Scott D. [2 ]
Ross, Steven G. [2 ]
Stearns, Charles W. [2 ]
机构
[1] GE Res, Niskayuna, NY 12309 USA
[2] GE Healthcare, Waukesha, WI 53188 USA
关键词
D O I
10.1109/NSSMIC.2009.5401923
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Many implementations of model based scatter correction (MBSC) are based on the single scatter simulation (SSS) formulation within the scan field-of-view (FOV). A fully 3D approach that models both the axial and trans-axial scatter components can accurately model scatter from hot regions in neighboring slices and outside the scan FOV resulting in greater quantitative accuracy. Herein we discuss how to incorporate the estimation of out-of-field scatter in fully 3D MBSC.
引用
收藏
页码:3886 / +
页数:2
相关论文
共 50 条
  • [21] Effect of spatial behavior of scatter on 3D PET
    Jan, ML
    Pei, CC
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 376 - 387
  • [22] Implementation of on-the-fly scatter correction using dual energy window method in continuous 3D whole body PET scanning
    Ishikawa, Akihiro
    Kitamura, Keishi
    Mizuta, Tetsuro
    Amano, Kazumi Tanaka Masaharu
    Inoue, Yoshihiro
    Matsumoto, Keiichi
    Senda, Michio
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2497 - 2500
  • [23] Optimization of a fully 3D single scatter simulation algorithm for 3D PET
    Accorsi, R
    Adam, LE
    Werner, ME
    Karp, JS
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12): : 2577 - 2598
  • [24] Modeling and incorporation of system response functions in 3D whole body PET
    Alessio, AM
    Kinahan, PE
    Lewellen, TK
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3992 - 3996
  • [25] Strategies to improve 3D whole-body PET image reconstruction
    Cutler, PD
    Xu, M
    PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (08): : 1453 - 1467
  • [26] A prototype axial shield for use in 3D whole-body PET
    Cutler, PD
    Laforest, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) : 10 - 15
  • [27] Whole-body PET scanner produces 3D images in seconds
    Sara Reardon
    Nature, 2019, 570 : 285 - 286
  • [28] openSSS: an open-source implementation of scatter estimation for 3D TOF-PET
    Jose Santo, Rodrigo
    Salomon, Andre
    de Jong, Hugo W. A. M.
    Stute, Simon
    Merlin, Thibaut
    Beijst, Casper
    EJNMMI PHYSICS, 2025, 12 (01):
  • [29] Effects of out-of-field radioactivity on dedicated breast PET images
    Satoh, Y.
    Imai, M.
    Ikegawa, C.
    Hirata, K.
    Abo, N.
    Kusuzaki, M.
    Oyama-Manabe, N.
    Onishi, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S461 - S461
  • [30] OUT-OF-FIELD DOSE MEASUREMENTS FOR 3D CONFORMAL AND INTENSITY MODULATED RADIOTHERAPY OF A PAEDIATRIC BRAIN TUMOUR
    Majer, Marija
    Stolarczyk, Liliana
    De Saint-Hubert, Marijke
    Kabat, Damian
    Knezevic, Zeljka
    Miljanic, Saveta
    Mojzeszek, Natalia
    Harrison, Roger
    RADIATION PROTECTION DOSIMETRY, 2017, 176 (03) : 331 - 340