Out-of-Field Scatter Estimation in 3D Whole body PET

被引:9
|
作者
Iatrou, Maria [1 ]
Manjeshwar, Ravindra M. [1 ]
Wollenweber, Scott D. [2 ]
Ross, Steven G. [2 ]
Stearns, Charles W. [2 ]
机构
[1] GE Res, Niskayuna, NY 12309 USA
[2] GE Healthcare, Waukesha, WI 53188 USA
关键词
D O I
10.1109/NSSMIC.2009.5401923
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Many implementations of model based scatter correction (MBSC) are based on the single scatter simulation (SSS) formulation within the scan field-of-view (FOV). A fully 3D approach that models both the axial and trans-axial scatter components can accurately model scatter from hot regions in neighboring slices and outside the scan FOV resulting in greater quantitative accuracy. Herein we discuss how to incorporate the estimation of out-of-field scatter in fully 3D MBSC.
引用
收藏
页码:3886 / +
页数:2
相关论文
共 50 条
  • [1] High accuracy multiple scatter modelling for 3D whole body PET
    Markiewicz, P. J.
    Tamal, M.
    Julyan, P. J.
    Hastings, D. L.
    Reader, A. J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (03): : 829 - 847
  • [2] 3D implementation of Scatter Estimation in 3D PET
    Iatrou, M.
    Manjeshwar, R. M.
    Ross, S. G.
    Thielemans, K.
    Stearns, C. W.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2142 - 2145
  • [3] Design of patient shielding to reduce the effects of out-of-field radioactivity in 3D PET
    Daube-Witherspoon, M.E.
    Belakhlef, A.
    Green, S.L.
    Zanzi, I.
    IEEE Nuclear Science Symposium and Medical Imaging Conference, 1999, 2 : 1237 - 1242
  • [4] High Accuracy Multiple Order Scatter Model for 3D Whole Body PET
    Markiewicz, P. J.
    Tamal, M.
    Julyan, P. J.
    Hastings, D. L.
    Reader, A. J.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2748 - 2752
  • [5] Parameterization of a model-based 3D whole-body PET scatter correction
    Wollenweber, SD
    2001 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORDS, VOLS 1-4, 2002, : 1471 - 1475
  • [6] An effective scatter correction method based on single scatter simulation for a 3D whole-body PET scanner
    高飞
    Yamada Ryoko
    Watanabe Mitsuo
    刘华锋
    Chinese Physics B, 2009, 18 (07) : 3066 - 3072
  • [7] An effective scatter correction method based on single scatter simulation for a 3D whole-body PET scanner
    Gao Fei
    Ryoko, Yamada
    Mitsuo, Watanabe
    Liu Hua-Feng
    CHINESE PHYSICS B, 2009, 18 (07) : 3066 - 3072
  • [8] Comparison of two 3D implementations of TOF Scatter Estimation in 3D PET
    Iatrou, Maria
    Manjeshwar, Ravindra M.
    Sterns, Charles W.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3474 - +
  • [9] Attenuation and Scatter Correction for Whole-body PET Using 3D Generative Adversarial Networks
    Yang, Xiaofeng
    Lei, Yang
    Dong, Xue
    Wang, Tonghe
    Higgins, Kristin
    Liu, Tian
    Shim, Hyunsuk
    Curran, Walter
    Mao, Hui
    Nye, Jonathon
    JOURNAL OF NUCLEAR MEDICINE, 2019, 60
  • [10] Studies on Scattered Radiation out of Field of View and Effect of Scatter Correction in 3D brain PET
    Honda, M.
    Sakuragi, Y.
    Abe, S.
    Fujita, N.
    Kunimoto, K.
    Odagawa, T.
    Kato, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S866 - S866