AN INFLUENZA HEMAGGLUTININ A PEPTIDE ASSAY BASED ON THE ENZYME-MULTIPLIED IMMUNOASSAY TECHNIQUE

被引:4
|
作者
Chiu, May L. [1 ]
Lai, Denton [1 ]
Monbouquette, Harold G. [1 ]
机构
[1] Univ Calif Los Angeles, Chem & Biomol Engn Dept, Los Angeles, CA 90095 USA
来源
基金
美国国家卫生研究院;
关键词
EMIT; enzyme multiplied immunoassay technique; hemagglutinin A; peptide detection; GLUCOSE 6-PHOSPHATE DEHYDROGENASE; BETA-GALACTOSIDASE; LEUCONOSTOC-MESENTEROIDES; HOMOGENEOUS IMMUNOASSAYS; PROTEIN; SENSITIVITY; OPIATES; EMIT;
D O I
10.1080/15321819.2011.538623
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A practical approach for constructing enzyme-multiplied immunoassay technique (EMIT)-based protein/ peptide assays is described. Normally used in small-molecule drug testing, EMIT is a homogeneous assay method that is attractive for its simplicity, sensitivity, and rapidity. The EMIT-based peptide/ protein assay was developed by conjugating a cysteine-modified HA peptide (from influenza hemagglutinin A) to the reporter enzyme, glucose-6-phosphate dehydrogenase. The 13-min assay gave a free HA limit of detection of 10 nM and proved effective for detection of a high-molecular-weight model protein tagged with HA. Similar EMIT-based assay approaches may be developed for applications in biotoxin and infectious disease detection.
引用
收藏
页码:1 / 17
页数:17
相关论文
共 50 条
  • [31] Reliability of Mycophenolic Acid Monitoring by an Enzyme Multiplied Immunoassay Technique
    Martiny, Delphine
    Macours, Pascale
    Cotton, Frederic
    Thiry, Philippe
    Gulbis, Beatrice
    CLINICAL LABORATORY, 2010, 56 (7-8) : 345 - 353
  • [32] RENAL-DISEASE MAY INCREASE APPARENT PHENYTOIN IN SERUM AS MEASURED BY ENZYME-MULTIPLIED IMMUNOASSAY - REPLY
    RUBENSTEIN, K
    BASTIANI, R
    CLINICAL CHEMISTRY, 1980, 26 (02) : 362 - 362
  • [33] COMPARISON OF PHENYTOIN AND CARBAMAZEPINE SERUM CONCENTRATIONS MEASURED BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY, THE STANDARD TDX ASSAY, THE ENZYME-MULTIPLIED IMMUNOASSAY TECHNIQUE, AND A NEW PATIENT-SIDE IMMUNOASSAY CARTRIDGE SYSTEM
    RAMBECK, B
    MAY, TW
    JURGENS, U
    BLANKENHORN, V
    JURGES, U
    KORNMERKER, E
    THERAPEUTIC DRUG MONITORING, 1994, 16 (06) : 608 - 612
  • [34] Parent cyclosporine in whole blood by monoclonal fluorescence polarization immunoassay for AxSym and monoclonal enzyme-multiplied immunoassay for Cobas-Fara
    De Cos, MA
    Adín, J
    Gutiérrez-Iñiguez, MA
    Armijo, JA
    CLINICAL BIOCHEMISTRY, 1998, 31 (08) : 681 - 685
  • [35] EVALUATION OF INSTRUMENTAL, NONISOTOPIC IMMUNOASSAYS (FLUORESCENCE POLARIZATION IMMUNOASSAY AND ENZYME-MULTIPLIED IMMUNOASSAY TECHNIQUE) FOR CYCLOSPORINE MONITORING IN WHOLE-BLOOD AFTER KIDNEY AND LIVER-TRANSPLANTATION
    BEUTLER, D
    MOLTENI, S
    ZEUGIN, T
    THORMANN, W
    THERAPEUTIC DRUG MONITORING, 1992, 14 (05) : 424 - 432
  • [36] An optoelectronic biomedical method for amphetamine detection by enzyme multiplied immunoassay technique
    Caragea, Genica
    Forje, Margarita
    Avram, Ruxandra
    Varzaru, Andreea Camelia
    Vladescu, Marian
    Tudosie, Mihail Silviu
    Schiopu, Paul
    ADVANCED TOPICS IN OPTOELECTRONICS, MICROELECTRONICS AND NANOTECHNOLOGIES X, 2020, 11718
  • [37] Comparison of New Liquid Chromatography-Mass Spectrometry Method and Enzyme-Multiplied Immunoassay Technique for Routine Therapeutic Drug Monitoring of Vancomycin in Chinese Patients
    Yuan, Guiyan
    Liu, Huanjun
    Shaikh, Abdul S.
    Zhang, Rui
    Li, Pingli
    Wang, Benjie
    Guo, Ruichen
    CLINICAL LABORATORY, 2018, 64 (03) : 277 - 285
  • [38] SINGLE RADIAL IMMUNODIFFUSION TECHNIQUE FOR ASSAY OF INFLUENZA HEMAGGLUTININ ANTIGEN - PROPOSALS FOR AN ASSAY METHOD FOR HEMAGGLUTININ CONTENT OF INFLUENZA VACCINES
    SCHILD, GC
    WOOD, JM
    NEWMAN, RW
    BULLETIN OF THE WORLD HEALTH ORGANIZATION, 1975, 52 (02): : 223 - 231
  • [39] Comparison of HPLC-MS/MS and Enzyme-multiplied Immunoassay in Tacrolimus Determination and its Application in Therapeutic Drug Monitoring
    Li, Wenlong
    Yuan, Guiyan
    Liu, Huanjun
    Shaikh, Abdul S.
    Kong, Xianglin
    Wang, Yanyan
    Guo, Ruichen
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (08): : 1540 - 1546
  • [40] Processing Validation Metrics of Syva Enzyme- Multiplied Immunoassay Technique (EMIT) Methotrexate Assay for Beckman Coulter System
    Nayak, Saurav
    Patel, Suprava
    Nanda, Rachita
    Shah, Seema
    Mohapatra, Eli
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (01)