Reproducibility of isokinetic test findings for assessment of wrist spasticity in stroke patients

被引:4
|
作者
Cetin, Nuri
Dilek, Ayse
Aytar, Aydan
Akman, Mahmut Nafiz
机构
[1] Baskent Univ, Dept Phys Med & Rehabil, TR-06490 Ankara, Turkey
[2] Baskent Univ, Dept Phys Therapy & Rehabil, TR-06490 Ankara, Turkey
关键词
spasticity; isokinetic dynamometry; reproducibility; stroke;
D O I
10.3233/IES-2008-0297
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We aimed to determine the test-retest reproducibility of isokinetic dynamometric measurement of the resistance to passive motion for quantitative evaluation of wrist flexor spasticity in stroke patients. In a repeated measures design, 2 raters tested each subject 3 times on 6 separate days. Twenty one sub-acute/chronic stroke patients 55 +/- 14.1 years of age with an average disease duration of 7.04 +/- 2.87 months volunteered to take part along with 20 age-matched healthy controls. Clinical assessment of spasticity was performed using an Ashworth Scale. Resistance measurements of 5 consecutive flexion/extension movements of the wrists were performed at 3 reselected angular velocities ( 10 degrees/ s, 30 degrees/ s, 45 degrees/ s), using a computerized dynamometer, set in the continuous passive joint motion mode. The maximum peak torque values in for each subject were calculated for each set of repetitions. The reproducibility of strength measurements were evaluated using single-measure and average-measure intra class correlation coefficients ( ICCs). There was a significant positive correlation between Ashworth Scale and torque values. Torque values were significantly higher in groups with patients who had strokes than in the control group. The dynamometric scores were positively correlated with Ashworth Scale grades. The ICCs for intra-tester measurements were high and ranged 0.82-0.87. The Bland-Altman plots indicated no systematic bias. The standard error of measurement ( SEM) ranged 0.27-0.38 Nm while the smallest real difference ( SRD) ranged -1.0 Nm to 1.1 Nm). These values correspond to a mean SEM% of 31% and SRD% of 85%. These values indicate relatively large measurement error and thus does not support the use of isokinetic dynamometry, using this protocol and measurement system, in assessing wrist muscles spasticity in stroke patients.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [41] Comparing the validity of the Modified Modified Ashworth Scale (MMAS) and the Modified Tardieu Scale (MTS) in the assessment of wrist flexor spasticity in patients with stroke: protocol for a neurophysiological study
    Abolhasani, Hamid
    Ansari, Noureddin Nakhostin
    Naghdi, Soofia
    Mansouri, Korosh
    Ghotbi, Nastaran
    Hasson, Scott
    BMJ OPEN, 2012, 2 (06):
  • [42] Measurement of elbow spasticity in stroke patients using a manual spasticity evaluator
    Wu, Yi-Ning
    Park, Hyung Soon
    Ren, Yupeng
    Gaebler-Spira, Deborah
    Chen, Jia-Jin
    Zhang, Li-Qun
    2006 28TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-15, 2006, : 5484 - +
  • [43] Extracorporeal shock wave as adjuvant therapy for wrist and hand spasticity in post-stroke patients: a randomized controlled trial
    Tabra, Samar Abd Alhamed
    Zaghloul, Mohammad Ibrahim
    Alashkar, Doaa Shawky
    EGYPTIAN RHEUMATOLOGY AND REHABILITATION, 2021, 48 (01)
  • [44] A comparative study between the effect of low level laser therapy and hand splint on the spasticity of wrist flexors in stroke patients
    Saad, Zeinab Nagy
    Eid, Ghada Shaaban
    Nawito, Amani Mahmoud
    Kamel, Ragia Mohamed
    Mostafa, Yousry Mahmoud
    BIOSCIENCE RESEARCH, 2019, 16 (02): : 2254 - 2265
  • [45] Extracorporeal shock wave as adjuvant therapy for wrist and hand spasticity in post-stroke patients: a randomized controlled trial
    Samar Abd Alhamed Tabra
    Mohammad Ibrahim Zaghloul
    Doaa Shawky Alashkar
    Egyptian Rheumatology and Rehabilitation, 2021, 48
  • [46] Continuous versus separate isokinetic test protocol:: The effect of estradiol on the reproducibility of concentric and eccentric isokinetic measurements in knee muscles
    Gür, H
    Akova, B
    Kücükoglu, S
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (09): : 1024 - 1029
  • [47] Effects of Functional Electrical Stimulation on Wrist Function and Spasticity in Stroke: A Randomized Controlled Study
    Karakus, Dilek
    Ersoz, Murat
    Koyuncu, Gonul
    Turk, Dilek
    Sasmaz, Fatma Munevver
    Akyuz, Mufit
    TURKIYE FIZIKSEL TIP VE REHABILITASYON DERGISI-TURKISH JOURNAL OF PHYSICAL MEDICINE AND REHABILITATION, 2013, 59 (02): : 97 - 102
  • [48] Isokinetic evaluation of wrist muscle strength in patients of carpal tunnel syndrome
    Agirman, Mehmet
    Kara, Adnan
    Durmus, Oguz
    Saral, Ilknur
    Cakar, Engin
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2017, 28 (01): : 41 - 45
  • [49] Assessment of Spasticity With Sonoelastography Following Stroke: A Feasibility Study
    Kesikburun, Serdar
    Yasar, Evren
    Adiguzel, Emre
    Guzelkucuk, Umut
    Alaca, Ridvan
    Tan, Arif Kenan
    PM&R, 2015, 7 (12) : 1254 - 1260
  • [50] Isokinetic assessment of hip muscle concentric strength in normal subjects: A reproducibility study
    Dugailly, PM
    Brassinne, E
    Pirotte, E
    Mouraux, D
    Feipel, V
    Klein, P
    ISOKINETICS AND EXERCISE SCIENCE, 2005, 13 (02) : 129 - 137