Reproducibility of isokinetic test findings for assessment of wrist spasticity in stroke patients

被引:4
|
作者
Cetin, Nuri
Dilek, Ayse
Aytar, Aydan
Akman, Mahmut Nafiz
机构
[1] Baskent Univ, Dept Phys Med & Rehabil, TR-06490 Ankara, Turkey
[2] Baskent Univ, Dept Phys Therapy & Rehabil, TR-06490 Ankara, Turkey
关键词
spasticity; isokinetic dynamometry; reproducibility; stroke;
D O I
10.3233/IES-2008-0297
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We aimed to determine the test-retest reproducibility of isokinetic dynamometric measurement of the resistance to passive motion for quantitative evaluation of wrist flexor spasticity in stroke patients. In a repeated measures design, 2 raters tested each subject 3 times on 6 separate days. Twenty one sub-acute/chronic stroke patients 55 +/- 14.1 years of age with an average disease duration of 7.04 +/- 2.87 months volunteered to take part along with 20 age-matched healthy controls. Clinical assessment of spasticity was performed using an Ashworth Scale. Resistance measurements of 5 consecutive flexion/extension movements of the wrists were performed at 3 reselected angular velocities ( 10 degrees/ s, 30 degrees/ s, 45 degrees/ s), using a computerized dynamometer, set in the continuous passive joint motion mode. The maximum peak torque values in for each subject were calculated for each set of repetitions. The reproducibility of strength measurements were evaluated using single-measure and average-measure intra class correlation coefficients ( ICCs). There was a significant positive correlation between Ashworth Scale and torque values. Torque values were significantly higher in groups with patients who had strokes than in the control group. The dynamometric scores were positively correlated with Ashworth Scale grades. The ICCs for intra-tester measurements were high and ranged 0.82-0.87. The Bland-Altman plots indicated no systematic bias. The standard error of measurement ( SEM) ranged 0.27-0.38 Nm while the smallest real difference ( SRD) ranged -1.0 Nm to 1.1 Nm). These values correspond to a mean SEM% of 31% and SRD% of 85%. These values indicate relatively large measurement error and thus does not support the use of isokinetic dynamometry, using this protocol and measurement system, in assessing wrist muscles spasticity in stroke patients.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [31] Intramuscular injection of botulinum toxin for the treatment of wrist and finger spasticity after a stroke
    Brashear, A
    Gordon, MF
    Elovic, E
    Kassicieh, VD
    Marciniak, C
    Lee, CH
    Jenkins, S
    Turkel, C
    NEW ENGLAND JOURNAL OF MEDICINE, 2002, 347 (06): : 395 - 400
  • [32] Impact of onabotulinumtoxina therapy in patients with post-stroke spasticity (PSS): Findings from the BOTOX Economic spasticity trial (BEST)
    Sharma, S.
    Wein, T.
    Satkunam, L.
    Bhogal, M.
    Fulford-Smith, A.
    Dhani, S.
    STROKE, 2012, 43 (11) : E116 - E116
  • [33] The effect of electro-acupuncture on spasticity of the wrist joint in chronic stroke survivors
    Mukherjee, Mukul
    McPeak, Lisa K.
    Redford, John B.
    Sun, Chao
    Liu, Wen
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2007, 88 (02): : 159 - 166
  • [34] Spasticity after stroke: Physiology, assessment and treatment
    Thibaut, Aurore
    Chatelle, Camille
    Ziegler, Erik
    Bruno, Marie-Aurelie
    Laureys, Steven
    Gosseries, Olivia
    BRAIN INJURY, 2013, 27 (10) : 1093 - 1105
  • [35] Interrater Reliability of the Modified Tardieu Scale in the Assessment of Muscle Spasticity in Stroke Patients
    Nakhostin-Ansari, Nouroddin
    Naghdi, Soufia
    O'liaei, Gholam Reza
    Abdolvahhab, Mahdi
    Jalili, Mahmoud
    Jalaei, Shohreh
    Soltani-Nezhad, Hossein
    ARCHIVES OF REHABILITATION, 2009, 9 (3-4): : 22 - 27
  • [36] Validity of the modified Tardieu Scale in measuring wrist flexor spasticity after stroke
    Naghdi, S.
    Ansari, N. Nakhostin
    Abolhasani, H.
    Mansouri, K.
    Ghotbi, N.
    Hasson, S.
    INTERNATIONAL JOURNAL OF STROKE, 2014, 9 : 266 - 266
  • [37] ASSESSMENT OF UPPER LIMB SPASTICITY IN STROKE PATIENTS USING THE ROBOTIC DEVICE REAPLAN
    Dehem, Stephanie
    Gilliaux, Maxime
    Lejeune, Thierry
    Detrembleur, Christine
    Galinski, Daniel
    Sapin, Julien
    Vanderwegen, Martin
    Stoquart, Gaetan
    JOURNAL OF REHABILITATION MEDICINE, 2017, 49 (07) : 565 - 571
  • [38] VARIABILITY AND RELIABILITY OF THE PENDULUM TEST FOR SPASTICITY USING A CYBEX-II ISOKINETIC DYNAMOMETER
    BOHANNON, RW
    PHYSICAL THERAPY, 1987, 67 (05): : 659 - 661
  • [39] Preliminary evaluation of a robotic measurement system for the assessment of wrist joint spasticity
    Falzarano, Valeria
    Petrella, Giulia
    Marini, Francesca
    Holmes, Michael W. R.
    Masia, Lorenzo
    Morasso, Pietro
    Zenzeri, Jacopo
    2020 8TH IEEE RAS/EMBS INTERNATIONAL CONFERENCE FOR BIOMEDICAL ROBOTICS AND BIOMECHATRONICS (BIOROB), 2020, : 539 - 544
  • [40] Reproducibility and validity of a new test protocol for measuring isokinetic trunk extension strength
    Dvir, Z
    Keating, J
    CLINICAL BIOMECHANICS, 2001, 16 (07) : 627 - 630