Reproducibility of isokinetic test findings for assessment of wrist spasticity in stroke patients

被引:4
|
作者
Cetin, Nuri
Dilek, Ayse
Aytar, Aydan
Akman, Mahmut Nafiz
机构
[1] Baskent Univ, Dept Phys Med & Rehabil, TR-06490 Ankara, Turkey
[2] Baskent Univ, Dept Phys Therapy & Rehabil, TR-06490 Ankara, Turkey
关键词
spasticity; isokinetic dynamometry; reproducibility; stroke;
D O I
10.3233/IES-2008-0297
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We aimed to determine the test-retest reproducibility of isokinetic dynamometric measurement of the resistance to passive motion for quantitative evaluation of wrist flexor spasticity in stroke patients. In a repeated measures design, 2 raters tested each subject 3 times on 6 separate days. Twenty one sub-acute/chronic stroke patients 55 +/- 14.1 years of age with an average disease duration of 7.04 +/- 2.87 months volunteered to take part along with 20 age-matched healthy controls. Clinical assessment of spasticity was performed using an Ashworth Scale. Resistance measurements of 5 consecutive flexion/extension movements of the wrists were performed at 3 reselected angular velocities ( 10 degrees/ s, 30 degrees/ s, 45 degrees/ s), using a computerized dynamometer, set in the continuous passive joint motion mode. The maximum peak torque values in for each subject were calculated for each set of repetitions. The reproducibility of strength measurements were evaluated using single-measure and average-measure intra class correlation coefficients ( ICCs). There was a significant positive correlation between Ashworth Scale and torque values. Torque values were significantly higher in groups with patients who had strokes than in the control group. The dynamometric scores were positively correlated with Ashworth Scale grades. The ICCs for intra-tester measurements were high and ranged 0.82-0.87. The Bland-Altman plots indicated no systematic bias. The standard error of measurement ( SEM) ranged 0.27-0.38 Nm while the smallest real difference ( SRD) ranged -1.0 Nm to 1.1 Nm). These values correspond to a mean SEM% of 31% and SRD% of 85%. These values indicate relatively large measurement error and thus does not support the use of isokinetic dynamometry, using this protocol and measurement system, in assessing wrist muscles spasticity in stroke patients.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [21] Test-retest reliability of isometric and isokinetic wrist strength
    Prando, Beatriz Cardinal
    Carvalho, Cristiano
    Petrella, Marina
    Serrao, Paula Regina Mendes da Silva
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2023, 28 (01) : 138 - 142
  • [22] Generating the Visual Biofeedback Signals Applicable to Reduction of Wrist Spasticity: A Pilot Study on Stroke Patients
    Zadnia, Afsane
    Kobravi, Hamid Reza
    Sheikh, Mania
    Hosseini, Hossein Asghar
    BASIC AND CLINICAL NEUROSCIENCE, 2018, 9 (01) : 15 - 26
  • [23] Effectiveness and Usability of Hand-Wrist Stretching Device for Spasticity in Chronic Hemiparetic Stroke Patients
    Lo, Chi-Hung
    Ko, Ya-Chuan
    Fan, Shih-Chen
    Chiu, Hsiao-Ping
    SENSORS AND MATERIALS, 2024, 36 (05) : 1777 - 1786
  • [24] Isokinetic assessment of the effects of botulinum toxin injection on spasticity and voluntary strength in patients with spastic hemiparesis
    Hameau, S.
    Bensmail, D.
    Robertson, J.
    Boudarham, J.
    Roche, N.
    Zory, R.
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2014, 50 (05) : 515 - 523
  • [25] Test-retest reproducibility of isokinetic lifting strength measurements
    Yuzer, Serdil
    Aydog, Ece
    Gurcay, Eda
    Unlu, Ece
    Cakci, Aytul
    ISOKINETICS AND EXERCISE SCIENCE, 2008, 16 (02) : 113 - 118
  • [26] Isokinetic assessment of spasticity in subjects with traumatic spinal cord injury (ASIA A)
    AC Franzoi
    C Castro
    C Cardone
    Spinal Cord, 1999, 37 : 416 - 420
  • [27] Isokinetic assessment of spasticity in subjects with traumatic spinal cord injury (ASIA A)
    Franzoi, AC
    Castro, C
    Cardone, C
    SPINAL CORD, 1999, 37 (06) : 416 - 420
  • [28] Improving the test-retest and inter-rater reliability for stretch reflex measurements using an isokinetic device in stroke patients with mild to moderate elbow spasticity
    Sin, Minki
    Kim, Won-Seok
    Cho, Kyujin
    Cho, Sungmin
    Paik, Nam-Jong
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2018, 39 : 120 - 127
  • [29] Test-retest reliability of isokinetic dynamometry for the assessment of spasticity of the knee flexors and knee extensors in children with cerebral palsy
    Pierce, SR
    Lauer, RT
    Shewokis, PA
    Rubertone, JA
    Orlin, MN
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2006, 87 (05): : 697 - 702
  • [30] Test-retest reliability of isokinetic muscle strength of the lower extremities in patients with stroke
    Hsu, AL
    Tang, PF
    Jan, MH
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (08): : 1130 - 1137