Purpose: To develop a method for deriving phase‐binned 3D CT images through the interpolation of CT images at 2∼3 known phase points. Method and Materials: 4D‐CT dataset for 3 patients were acquired. The deformation between inhale and exhale phases was quantified using a BSpline image registration model. During the registration calculation, the displacement coefficients defined on a lattice of nodes overlaid on the image were iteratively modified until optimal match was achieved. Images at an arbitrary phase were deduced by direct interpolation of the node coefficients. The interpolated images were compared with the actual 4D dataset and the results were evaluated by measuring the displacements of implanted fiducials in the two sets of images. Checkerboard and subtraction images between the interpolated and actual images were also computed. Results: The model was capable of describing the patient‐specific anatomical deformation between the inhale and exhale phases and generating images at intermediate phases with a 3 mm accuracy. Subtraction images indicated only 0.1% of voxels having a difference >20 HU. The technique also mapped the organ contours at a known phase to other phases and provided an effective way for designing patient‐specific margins in the presence of respiratory motion. Finally, the technique lead to a 90% reduction in the stored data because the 4D CT dataset of 25 million pixels can now be described by only a few thousand BSpline lattice points. Conclusion: Organ deformation during the breathing process can be modeled by using an interpolation of the deformation field with 3mm accuracy. To obtain images at any phase during a breathing cycle, it seems adequate to acquire only 2∼3 sets of images at some distinct phases such as inhale and exhale points. The technique offers a practical solution for 4D‐CT acquisition with greatly reduced radiation dose and binning artifacts. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1924 / 1924
页数:1
相关论文
共 50 条
  • [1] Image interpolation in 4D CT using a BSpline deformable registration model
    Schreibmann, E
    Chen, GTY
    Xing, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (05): : 1537 - 1550
  • [2] Image segmentation in 4D CT based on a deformable image registration model
    Xing, L
    Schreibmann, E
    Yang, Y
    Boyer, A
    Li, T
    MEDICAL PHYSICS, 2005, 32 (06) : 2095 - 2095
  • [3] ADVANCES IN DEFORMABLE IMAGE REGISTRATION OF THORACIC 4D CT
    Sarrut, D.
    Vandemeulebroucke, J.
    Rit, S.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S188 - S189
  • [4] 4D CT Image Simulation Using B-Spline Deformable Model and Cosine Interpolation of Deformation field
    Tian, Zhen
    Yuan, Kehong
    Bai, Yanling
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3541 - 3544
  • [5] Evaluation of Liver Deformation During Breathing Using Deformable Image Registration: A Comparison Between 4D CT and 4D MRI
    Liang, X.
    Czito, B.
    Palta, M.
    Bashir, M.
    Yin, F.
    Cai, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 171 - 171
  • [6] Efficient 4D Treatment Planning Using CT Datasets Synthesized Via Deformable Image Registration
    Zhong, H.
    Fragoso, M.
    Chetty, I.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [7] Automatic contour generation of 4D CT by deformable registration
    Duan, Zhuolei
    Zhou, Fugen
    Liu, Bo
    Deng, Xiaowu
    Chen, Ming
    Huang, Xiaoyan
    PACIIA: 2008 PACIFIC-ASIA WORKSHOP ON COMPUTATIONAL INTELLIGENCE AND INDUSTRIAL APPLICATION, VOLS 1-3, PROCEEDINGS, 2008, : 1170 - +
  • [8] Dependence of ventilation image derived from 4D CT on deformable image registration and ventilation algorithms
    Latifi, Kujtim
    Forster, Kenneth M.
    Hoffe, Sarah E.
    Dilling, Thomas J.
    van Elmpt, Wouter
    Dekker, Andre
    Zhang, Geoffrey G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 150 - 162
  • [9] Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm
    Wijesooriya, Krishni
    Weiss, E.
    Dill, V.
    Dong, L.
    Mohan, R.
    Joshi, S.
    Keall, P. J.
    MEDICAL PHYSICS, 2008, 35 (04) : 1251 - 1260
  • [10] Quantitative Assessment of Automatic Anatomy Segmentation of 4D CT Images Using a Deformable Image Registration Algorithm
    Dogan, N.
    Sleeman, W.
    Yan, C.
    Fatyga, M.
    Wu, J.
    Christensen, G.
    Hugo, G.
    Weiss, E.
    Williamson, J.
    MEDICAL PHYSICS, 2009, 36 (06)