Image interpolation in 4D CT using a BSpline deformable registration model

被引:9
|
作者
Schreibmann, E [1 ]
Yang, Y [1 ]
Boyer, A [1 ]
Li, T [1 ]
Xing, L [1 ]
机构
[1] Stanford Univ, Sch Med, Stanford, CA USA
关键词
D O I
10.1118/1.1997567
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a method for deriving phase‐binned 3D CT images through the interpolation of CT images at 2∼3 known phase points. Method and Materials: 4D‐CT dataset for 3 patients were acquired. The deformation between inhale and exhale phases was quantified using a BSpline image registration model. During the registration calculation, the displacement coefficients defined on a lattice of nodes overlaid on the image were iteratively modified until optimal match was achieved. Images at an arbitrary phase were deduced by direct interpolation of the node coefficients. The interpolated images were compared with the actual 4D dataset and the results were evaluated by measuring the displacements of implanted fiducials in the two sets of images. Checkerboard and subtraction images between the interpolated and actual images were also computed. Results: The model was capable of describing the patient‐specific anatomical deformation between the inhale and exhale phases and generating images at intermediate phases with a 3 mm accuracy. Subtraction images indicated only 0.1% of voxels having a difference >20 HU. The technique also mapped the organ contours at a known phase to other phases and provided an effective way for designing patient‐specific margins in the presence of respiratory motion. Finally, the technique lead to a 90% reduction in the stored data because the 4D CT dataset of 25 million pixels can now be described by only a few thousand BSpline lattice points. Conclusion: Organ deformation during the breathing process can be modeled by using an interpolation of the deformation field with 3mm accuracy. To obtain images at any phase during a breathing cycle, it seems adequate to acquire only 2∼3 sets of images at some distinct phases such as inhale and exhale points. The technique offers a practical solution for 4D‐CT acquisition with greatly reduced radiation dose and binning artifacts. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1924 / 1924
页数:1
相关论文
共 50 条
  • [41] How reliable are deformable image registration methods for scanned proton 4D dose calculations?
    Ribeiro, C. O.
    Knopf, A.
    Langendijk, J. A.
    Weber, D. C.
    Lomax, A. J.
    Zhang, Y.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S47 - S47
  • [42] Image Registration with Sliding Motion Constraints for 4D CT Motion Correction
    Derksen, Alexander
    Heldmann, Stefan
    Polzin, Thomas
    Berkels, Benjamin
    BILDVERARBEITUNG FUR DIE MEDIZIN 2015: ALGORITHMEN - SYSTEME - ANWENDUNGEN, 2015, : 335 - 340
  • [43] LungRegNet: An unsupervised deformable image registration method for 4D-CT lung
    Fu, Yabo
    Lei, Yang
    Wang, Tonghe
    Higgins, Kristin
    Bradley, Jeffrey D.
    Curran, Walter J.
    Liu, Tian
    Yang, Xiaofeng
    MEDICAL PHYSICS, 2020, 47 (04) : 1763 - 1774
  • [44] Registration of 4D CBCT and 4D CT for extracranial stereotactic treatments
    Elder, E.
    Schreibmann, E.
    Li, T.
    Fox, T.
    Xing, L.
    Crocker, J.
    Landry, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S651 - S651
  • [45] Deformable Registration-Based Image Estimation Method for 4D CBCT Using Region-Based PCA
    Harris, W.
    Zhang, Y.
    Yin, F.
    Ren, L.
    MEDICAL PHYSICS, 2015, 42 (06) : 3729 - 3730
  • [46] Influence of deformable image registration on 4D dose simulation for extracranial SBRT: A multi-registration framework study
    Mogadas, Nik
    Sothmann, Thilo
    Knopp, Tobias
    Gauer, Tobias
    Petersen, Cordula
    Werner, Rene
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 (02) : 225 - 232
  • [47] 4D Medical Image Registration: A Survey
    Girija, J.
    Murthy, G. N. Krishna
    Reddy, P. Chenna
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON INTELLIGENT SUSTAINABLE SYSTEMS (ICISS 2017), 2017, : 539 - 547
  • [48] Validation of a 4D Monte Carlo treatment planning tool using an image interpolation model
    Ding, M.
    Xing, L.
    Xiong, W.
    Stuhr, K.
    Newman, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S655 - S656
  • [49] Hybrid unsupervised paradigm based deformable image fusion for 4D CT lung image modality
    Iqbal, Muhammad Zafar
    Razzak, Imran
    Qayyum, Abdul
    Nguyen, Thanh Thi
    Tanveer, M.
    Sowmya, Arcot
    INFORMATION FUSION, 2024, 102
  • [50] 4D CT image reconstruction with diffeomorphic motion model
    Hinkle, Jacob
    Szegedi, Martin
    Wang, Brian
    Salter, Bill
    Joshi, Sarang
    MEDICAL IMAGE ANALYSIS, 2012, 16 (06) : 1307 - 1316