Image interpolation in 4D CT using a BSpline deformable registration model

被引:9
|
作者
Schreibmann, E [1 ]
Yang, Y [1 ]
Boyer, A [1 ]
Li, T [1 ]
Xing, L [1 ]
机构
[1] Stanford Univ, Sch Med, Stanford, CA USA
关键词
D O I
10.1118/1.1997567
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To develop a method for deriving phase‐binned 3D CT images through the interpolation of CT images at 2∼3 known phase points. Method and Materials: 4D‐CT dataset for 3 patients were acquired. The deformation between inhale and exhale phases was quantified using a BSpline image registration model. During the registration calculation, the displacement coefficients defined on a lattice of nodes overlaid on the image were iteratively modified until optimal match was achieved. Images at an arbitrary phase were deduced by direct interpolation of the node coefficients. The interpolated images were compared with the actual 4D dataset and the results were evaluated by measuring the displacements of implanted fiducials in the two sets of images. Checkerboard and subtraction images between the interpolated and actual images were also computed. Results: The model was capable of describing the patient‐specific anatomical deformation between the inhale and exhale phases and generating images at intermediate phases with a 3 mm accuracy. Subtraction images indicated only 0.1% of voxels having a difference >20 HU. The technique also mapped the organ contours at a known phase to other phases and provided an effective way for designing patient‐specific margins in the presence of respiratory motion. Finally, the technique lead to a 90% reduction in the stored data because the 4D CT dataset of 25 million pixels can now be described by only a few thousand BSpline lattice points. Conclusion: Organ deformation during the breathing process can be modeled by using an interpolation of the deformation field with 3mm accuracy. To obtain images at any phase during a breathing cycle, it seems adequate to acquire only 2∼3 sets of images at some distinct phases such as inhale and exhale points. The technique offers a practical solution for 4D‐CT acquisition with greatly reduced radiation dose and binning artifacts. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1924 / 1924
页数:1
相关论文
共 50 条
  • [31] Fast Groupwise 4D Deformable Image Registration for Irregular Breathing Motion Estimation
    Papiez, Bartlomiej W.
    McGowan, Daniel R.
    Skwarski, Michael
    Higgins, Geoff S.
    Schnabel, Julia A.
    Brady, Sir Michael
    BIOMEDICAL IMAGE REGISTRATION, WBIR 2018, 2018, 10883 : 37 - 46
  • [32] Quantifying the properties and accuracy of a deformable image registration algorithm for 4D treatment planning
    Wijesooriya, K.
    Weiss, E.
    Dill, V.
    Dong, L.
    Mohan, R.
    Joshi, S.
    Keall, P.
    MEDICAL PHYSICS, 2006, 33 (06) : 2186 - 2187
  • [33] Deformable registration of 4D computed tomography data
    Rietzel, Eike
    Chen, George T. Y.
    MEDICAL PHYSICS, 2006, 33 (11) : 4423 - 4430
  • [34] 4D CT Deformable Registration Using Unsupervised Deep Learning for Lung Stereotactic Body Radiation Therapy
    Yang, X.
    Fu, Y.
    Lei, Y.
    Tian, Z.
    Wang, T.
    Higgins, K. A.
    Shelton, J. W.
    Bradley, J. D.
    Curran, W. J., Jr.
    Liu, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E342 - E343
  • [35] Can 4D Dose Be Constructed Without Using Deformable Organ Registration?
    Liang, J.
    Chi, Y.
    Qin, X.
    Yan, D.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [36] 4D dose calculation for SBRT using deformable image registration and probability density function of lung tumor
    Shiinoki, T.
    Kawamura, S.
    Hanazawa, H.
    Uehara, T.
    Yuasa, Y.
    Park, S.
    Koike, M.
    Kanzaki, R.
    Shibuya, K.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S208 - S208
  • [37] Improving Image Quality in 4D-CT Scans Using Deformable Registration and Selective Averaging
    Aliotta, E.
    Thomas, D.
    Gaudio, S.
    White, B.
    Jani, S.
    Lee, P.
    Lamb, J.
    Low, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [38] Study of motion in a 4D-CT using deformable registration
    Boldea, V
    Sarrut, D
    Sharp, G
    Jiang, S
    Choi, N
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 63 (02): : S499 - S500
  • [39] Diffusion Deformable Model for 4D Temporal Medical Image Generation
    Kim, Boah
    Ye, Jong Chul
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2022, PT I, 2022, 13431 : 539 - 548
  • [40] Phase Correlated Image Registration to 4D CT for Liver Stereotactic Radiosurgery with Image Guidance CT
    Juh, R.
    Suh, T.