Image interpolation in 4D CT using a BSpline deformable registration model

被引:81
|
作者
Schreibmann, E
Chen, GTY
Xing, L
机构
[1] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
[2] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
关键词
four-dimensional computed tomography; deformable registration; image-guided radiotherapy; delineation; respiratory motion;
D O I
10.1016/j.ijrobp.2005.11.018
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To develop a method for deriving the phase-binned four-dimensional computed tomography (4D CT) image sets through interpolation of the images acquired at some known phases. Methods and Materials: Four-dimensional computed tomography data sets for 3 patients were acquired. For each patient, the correlation between inhale and exhale phases was studied and quantified using a BSpline deformable model. Images at an arbitrary phase were deduced by an interpolation of the deformation coefficients. The accuracy of the proposed scheme was assessed by comparing marker trajectories and by checkerboard/difference display of the interpolated and acquired images. Results: The images at intermediate phases could be derived by an interpolation of the deformation field. An analysis of marker movements indicated that 3 mm accuracy is achievable by the interpolation. The subtraction of image analysis indicated a similar level of success. The proposed technique was useful also for automatically mapping the organ contours in a known phase to other phases, and for designing patient-specific margins in the presence of respiratory motion. Finally, the technique led to a 90% reduction in the acquired data, because in the BSpline model, a lattice of only a few thousand values is sufficient to describe a CT data set of 25 million pixels. Conclusions: Organ deformation can be well modeled by using a BSpline model. The proposed technique may offer useful means for radiation dose reduction, binning artifacts removal, and disk storage improvement in 4D imaging. (c) 2006 Elsevier Inc.
引用
收藏
页码:1537 / 1550
页数:14
相关论文
共 50 条
  • [1] Image interpolation in 4D CT using a BSpline deformable registration model
    Schreibmann, E
    Yang, Y
    Boyer, A
    Li, T
    Xing, L
    MEDICAL PHYSICS, 2005, 32 (06) : 1924 - 1924
  • [2] Image segmentation in 4D CT based on a deformable image registration model
    Xing, L
    Schreibmann, E
    Yang, Y
    Boyer, A
    Li, T
    MEDICAL PHYSICS, 2005, 32 (06) : 2095 - 2095
  • [3] ADVANCES IN DEFORMABLE IMAGE REGISTRATION OF THORACIC 4D CT
    Sarrut, D.
    Vandemeulebroucke, J.
    Rit, S.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S188 - S189
  • [4] 4D CT Image Simulation Using B-Spline Deformable Model and Cosine Interpolation of Deformation field
    Tian, Zhen
    Yuan, Kehong
    Bai, Yanling
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3541 - 3544
  • [5] Evaluation of Liver Deformation During Breathing Using Deformable Image Registration: A Comparison Between 4D CT and 4D MRI
    Liang, X.
    Czito, B.
    Palta, M.
    Bashir, M.
    Yin, F.
    Cai, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 171 - 171
  • [6] Efficient 4D Treatment Planning Using CT Datasets Synthesized Via Deformable Image Registration
    Zhong, H.
    Fragoso, M.
    Chetty, I.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [7] Automatic contour generation of 4D CT by deformable registration
    Duan, Zhuolei
    Zhou, Fugen
    Liu, Bo
    Deng, Xiaowu
    Chen, Ming
    Huang, Xiaoyan
    PACIIA: 2008 PACIFIC-ASIA WORKSHOP ON COMPUTATIONAL INTELLIGENCE AND INDUSTRIAL APPLICATION, VOLS 1-3, PROCEEDINGS, 2008, : 1170 - +
  • [8] Dependence of ventilation image derived from 4D CT on deformable image registration and ventilation algorithms
    Latifi, Kujtim
    Forster, Kenneth M.
    Hoffe, Sarah E.
    Dilling, Thomas J.
    van Elmpt, Wouter
    Dekker, Andre
    Zhang, Geoffrey G.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 150 - 162
  • [9] Quantifying the accuracy of automated structure segmentation in 4D CT images using a deformable image registration algorithm
    Wijesooriya, Krishni
    Weiss, E.
    Dill, V.
    Dong, L.
    Mohan, R.
    Joshi, S.
    Keall, P. J.
    MEDICAL PHYSICS, 2008, 35 (04) : 1251 - 1260
  • [10] Quantitative Assessment of Automatic Anatomy Segmentation of 4D CT Images Using a Deformable Image Registration Algorithm
    Dogan, N.
    Sleeman, W.
    Yan, C.
    Fatyga, M.
    Wu, J.
    Christensen, G.
    Hugo, G.
    Weiss, E.
    Williamson, J.
    MEDICAL PHYSICS, 2009, 36 (06)