Image-Based Background Phase Error Correction in 4D Flow MRI Revisited

被引:37
|
作者
Busch, Julia [1 ,2 ]
Giese, Daniel [3 ]
Kozerke, Sebastian [1 ,2 ,4 ]
机构
[1] Univ Zurich, Inst Biomed Engn, Gloriastr 35, CH-8092 Zurich, Switzerland
[2] ETH, Gloriastr 35, CH-8092 Zurich, Switzerland
[3] Univ Hosp Cologne, Dept Radiol, Cologne, Germany
[4] Kings Coll London, Div Imaging Sci & Biomed Engn, London, England
基金
瑞士国家科学基金会;
关键词
APPARENT DIFFUSION-COEFFICIENT; PROSTATE-CANCER; WEIGHTED MRI; 3; T; METAANALYSIS; RESOLUTION; QUALITY; VALUES; LIVER; DWI;
D O I
10.1002/jmri.25668
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To correct background phase errors in phase-contrast magnetic resonance imaging ( MRI), image-based correction by referencing through stationary tissue is widely used. The aim of the present study was a detailed assessment of background phase errors in 4D Flow MRI and limitations of image-based correction. Materials and Methods: In a phantom study, 4D Flow MRI data were acquired for typical settings on two clinical 3T MR systems. Background errors were analyzed with respect to their spatial order and minimum requirements regarding the signal-to-noise ratio ( SNR) and the amount of stationary tissue for image-based correction were assessed. For in vivo evaluation, data of the aorta were acquired on one 3T MR system in five healthy subjects including subsequent scans on the stationary phantom as reference. Results: Background errors were found to exhibit spatial variation of first-to third-order. For correction, a minimum SNR of 20 was needed to achieve an error of less than 0.4% of the encoding velocity. The minimum amount of stationary tissue was strongly dependent on the spatial order requiring at least 25%, 60%, and 75% of stationary tissue for first-, second-, and third-order correction. In vivo evaluation showed that with 35-41% of stationary tissue available only first-order correction yielded a significant reduction ( P < 0.01). Conclusion: Background phase errors can range from first to third spatial order in 4D Flow MRI requiring correction with appropriate polynomials. At the same time, the limited amount of stationary tissue available in vivo limits imagebased background phase correction to first spatial order. Level of Evidence: 1 Technical Efficacy: Stage 1
引用
收藏
页码:1516 / 1525
页数:10
相关论文
共 50 条
  • [41] On the limitations of echo planar 4D flow MRI
    Dillinger, Hannes
    Walheim, Jonas
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2020, 84 (04) : 1806 - 1816
  • [42] Abdominal applications of quantitative 4D flow MRI
    Thekla H. Oechtering
    Grant S. Roberts
    Nikolaos Panagiotopoulos
    Oliver Wieben
    Alejandro Roldán-Alzate
    Scott B. Reeder
    Abdominal Radiology, 2022, 47 : 3229 - 3250
  • [43] Emerging Applications of Abdominal 4D Flow MRI
    Roldan-Alzate, Alejandro
    Francois, Christopher J.
    Wieben, Oliver
    Reeder, Scott B.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2016, 207 (01) : 58 - 66
  • [44] Cerebral hemodynamic changes of Takayasu arteritis based on 4D flow MRI
    Liu, Y.
    Sun, A.
    Ma, L.
    Jiang, L.
    Wang, H.
    Ding, J.
    Wang, X.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2022, 42 (1_SUPPL): : 218 - 218
  • [45] Editorial for "Evaluating a Phase-Specific Approach to Aortic Flow: A 4D Flow MRI Study"
    Cebull, Hannah L.
    Oshinski, John N.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (03) : 1068 - 1069
  • [46] Fully automated background phase correction using M-estimate SAmple consensus (MSAC)-Application to 2D and 4D flow
    Fischer, Carola
    Wetzl, Jens
    Schaeffter, Tobias
    Giese, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (06) : 2709 - 2717
  • [47] 4D Flow MRI Pressure Estimation Using Velocity Measurement-Error-Based Weighted Least-Squares
    Zhang, Jiacheng
    Brindise, Melissa C.
    Rothenberger, Sean
    Schnell, Susanne
    Markl, Michael
    Saloner, David
    Rayz, Vitaliy L.
    Vlachos, Pavlos P.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (05) : 1668 - 1680
  • [48] Comparison of turbulent flow measurement schemes for 4D flow MRI
    Ha, Hoijn
    Park, Hanwook
    JOURNAL OF VISUALIZATION, 2019, 22 (03) : 541 - 553
  • [49] Comparison of turbulent flow measurement schemes for 4D flow MRI
    Hoijn Ha
    Hanwook Park
    Journal of Visualization, 2019, 22 : 541 - 553
  • [50] 4D CT IMAGE RECONSTRUCTION BASED ON INTERPOLATED OPTICAL FLOW FIELDS
    Ouksili, Z.
    Batatia, H.
    2010 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, 2010, : 633 - 636