Image-Based Background Phase Error Correction in 4D Flow MRI Revisited

被引:37
|
作者
Busch, Julia [1 ,2 ]
Giese, Daniel [3 ]
Kozerke, Sebastian [1 ,2 ,4 ]
机构
[1] Univ Zurich, Inst Biomed Engn, Gloriastr 35, CH-8092 Zurich, Switzerland
[2] ETH, Gloriastr 35, CH-8092 Zurich, Switzerland
[3] Univ Hosp Cologne, Dept Radiol, Cologne, Germany
[4] Kings Coll London, Div Imaging Sci & Biomed Engn, London, England
基金
瑞士国家科学基金会;
关键词
APPARENT DIFFUSION-COEFFICIENT; PROSTATE-CANCER; WEIGHTED MRI; 3; T; METAANALYSIS; RESOLUTION; QUALITY; VALUES; LIVER; DWI;
D O I
10.1002/jmri.25668
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To correct background phase errors in phase-contrast magnetic resonance imaging ( MRI), image-based correction by referencing through stationary tissue is widely used. The aim of the present study was a detailed assessment of background phase errors in 4D Flow MRI and limitations of image-based correction. Materials and Methods: In a phantom study, 4D Flow MRI data were acquired for typical settings on two clinical 3T MR systems. Background errors were analyzed with respect to their spatial order and minimum requirements regarding the signal-to-noise ratio ( SNR) and the amount of stationary tissue for image-based correction were assessed. For in vivo evaluation, data of the aorta were acquired on one 3T MR system in five healthy subjects including subsequent scans on the stationary phantom as reference. Results: Background errors were found to exhibit spatial variation of first-to third-order. For correction, a minimum SNR of 20 was needed to achieve an error of less than 0.4% of the encoding velocity. The minimum amount of stationary tissue was strongly dependent on the spatial order requiring at least 25%, 60%, and 75% of stationary tissue for first-, second-, and third-order correction. In vivo evaluation showed that with 35-41% of stationary tissue available only first-order correction yielded a significant reduction ( P < 0.01). Conclusion: Background phase errors can range from first to third spatial order in 4D Flow MRI requiring correction with appropriate polynomials. At the same time, the limited amount of stationary tissue available in vivo limits imagebased background phase correction to first spatial order. Level of Evidence: 1 Technical Efficacy: Stage 1
引用
收藏
页码:1516 / 1525
页数:10
相关论文
共 50 条
  • [21] Coronary Flow Assessment Using Accelerated 4D Flow MRI With Respiratory Motion Correction
    Blanken, Carmen P. S.
    Schrauben, Eric M.
    Peper, Eva S.
    Gottwald, Lukas M.
    Coolen, Bram F.
    van Wijk, Diederik F.
    Piek, Jan J.
    Strijkers, Gustav J.
    Planken, R. Nils
    van Ooij, Pim
    Nederveen, Aart J.
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [22] 4D CT Image-Based Modeling the Deformation and Sliding Motion of Lungs
    Xie, Y.
    Chao, M.
    Xing, L.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [23] Manifold Learning for Image-Based Breathing Gating with Application to 4D Ultrasound
    Wachinger, Christian
    Yigitsoy, Mehmet
    Navab, Nassir
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2010, PT II,, 2010, 6362 : 26 - 33
  • [24] Spiral readouts for 4D flow MRI
    Andreas Sigfridsson
    Sven Petersson
    Carl Johan Carlhall
    Tino Ebbers
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [25] Abdominal Applications of 4D Flow MRI
    Riedel, Christoph
    Lenz, Alexander
    Fischer, Lutz
    Li, Jun
    Piecha, Feilix
    Kluwe, Johannes
    Adam, Gerhard
    Bannas, Peter
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (04): : 388 - 398
  • [26] Gastrointestinal 4D MRI with Respiratory Motion Correction
    Johansson, A.
    Balter, J.
    Cao, Y.
    MEDICAL PHYSICS, 2018, 45 (06) : E583 - E584
  • [27] Gastrointestinal 4D MRI with respiratory motion correction
    Johansson, Adam
    Balter, James M.
    Cao, Yue
    MEDICAL PHYSICS, 2021, 48 (05) : 2521 - 2527
  • [28] Technical Background for 4D Flow MR Imaging
    Terada, Masaki
    Takehara, Yasuo
    Isoda, Haruo
    Wakayama, Tetsuya
    Nozaki, Atsushi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (02) : 267 - 277
  • [29] Radiomics-based aortic flow profile characterization with 4D phase-contrast MRI
    Huellebrand, Markus
    Jarmatz, Lina
    Manini, Chiara
    Laube, Ann
    Ivantsits, Matthias
    Schulz-Menger, Jeanette
    Nordmeyer, Sarah
    Harloff, Andreas
    Hansmann, Jochen
    Kelle, Sebastian
    Hennemuth, Anja
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [30] In Vivo Image-Based 4D Modeling of Competent and Regurgitant Mitral Valve Dynamics
    A. H. Aly
    A. H. Aly
    E. K. Lai
    N. Yushkevich
    R. H. Stoffers
    J. H. Gorman
    A. T. Cheung
    J. H. Gorman
    R. C. Gorman
    P. A. Yushkevich
    A. M. Pouch
    Experimental Mechanics, 2021, 61 : 159 - 169