Image-Based Background Phase Error Correction in 4D Flow MRI Revisited

被引:37
|
作者
Busch, Julia [1 ,2 ]
Giese, Daniel [3 ]
Kozerke, Sebastian [1 ,2 ,4 ]
机构
[1] Univ Zurich, Inst Biomed Engn, Gloriastr 35, CH-8092 Zurich, Switzerland
[2] ETH, Gloriastr 35, CH-8092 Zurich, Switzerland
[3] Univ Hosp Cologne, Dept Radiol, Cologne, Germany
[4] Kings Coll London, Div Imaging Sci & Biomed Engn, London, England
基金
瑞士国家科学基金会;
关键词
APPARENT DIFFUSION-COEFFICIENT; PROSTATE-CANCER; WEIGHTED MRI; 3; T; METAANALYSIS; RESOLUTION; QUALITY; VALUES; LIVER; DWI;
D O I
10.1002/jmri.25668
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To correct background phase errors in phase-contrast magnetic resonance imaging ( MRI), image-based correction by referencing through stationary tissue is widely used. The aim of the present study was a detailed assessment of background phase errors in 4D Flow MRI and limitations of image-based correction. Materials and Methods: In a phantom study, 4D Flow MRI data were acquired for typical settings on two clinical 3T MR systems. Background errors were analyzed with respect to their spatial order and minimum requirements regarding the signal-to-noise ratio ( SNR) and the amount of stationary tissue for image-based correction were assessed. For in vivo evaluation, data of the aorta were acquired on one 3T MR system in five healthy subjects including subsequent scans on the stationary phantom as reference. Results: Background errors were found to exhibit spatial variation of first-to third-order. For correction, a minimum SNR of 20 was needed to achieve an error of less than 0.4% of the encoding velocity. The minimum amount of stationary tissue was strongly dependent on the spatial order requiring at least 25%, 60%, and 75% of stationary tissue for first-, second-, and third-order correction. In vivo evaluation showed that with 35-41% of stationary tissue available only first-order correction yielded a significant reduction ( P < 0.01). Conclusion: Background phase errors can range from first to third spatial order in 4D Flow MRI requiring correction with appropriate polynomials. At the same time, the limited amount of stationary tissue available in vivo limits imagebased background phase correction to first spatial order. Level of Evidence: 1 Technical Efficacy: Stage 1
引用
收藏
页码:1516 / 1525
页数:10
相关论文
共 50 条
  • [31] IMAGE-BASED MOTION DETECTION IN 4D IMAGES AND APPLICATION TO RESPIRATORY MOTION SUPPRESSION
    Breuilly, M.
    Malandain, G.
    Ayache, N.
    Guglielmi, J.
    Pourcher, T.
    Franken, P. R.
    Darcourt, J.
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 804 - 807
  • [32] In Vivo Image-Based 4D Modeling of Competent and Regurgitant Mitral Valve Dynamics
    Aly, A. H.
    Lai, E. K.
    Yushkevich, N.
    Stoffers, R. H.
    Gorman, J. H.
    Cheung, A. T.
    Gorman, H., III
    Gorman, R. C.
    Yushkevich, P. A.
    Pouch, A. M.
    EXPERIMENTAL MECHANICS, 2021, 61 (01) : 159 - 169
  • [33] Evaluating a Phase-Specific Approach to Aortic Flow: A 4D Flow MRI Study
    Ramaekers, Mitch J. F. G.
    Westenberg, Jos J. M.
    Venner, Max F. G. H. M.
    Juffermans, Joe F.
    van Assen, Hans C.
    te Kiefte, Bastiaan J. C.
    Adriaans, Bouke P.
    Lamb, Hildo J.
    Wildberger, Joachim E.
    Schalla, Simon
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 59 (03) : 1056 - 1067
  • [34] Sketch-based Registration of 3D Cine MRI to 4D flow MRI
    Sabokrohiyeh, Samin
    Ang, Kathleen
    Elbaz, Mohammed
    Samavati, Faramarz
    ICBBT 2019: 2019 11TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL TECHNOLOGY, 2019, : 14 - 21
  • [35] Image-based method for automated phase correction of ghost
    Chen, Chunxiao
    Luo, Limin
    Tao, Hua
    Wang, Shijie
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1352 - 1354
  • [36] The value of 4D flow MRI in cardiac assessment
    Nicholls, Mark
    EUROPEAN HEART JOURNAL, 2022, 43 (10) : 930 - 932
  • [37] 4D flow MRI velocity uncertainty quantification
    Rothenberger, Sean M.
    Zhang, Jiacheng
    Markl, Michael
    Craig, Bruce A.
    Vlachos, Pavlos P.
    Rayz, Vitaliy L.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (01) : 397 - 410
  • [38] Why 4D Flow MRI? Real Advantages
    Takehara, Yasuo
    Sekine, Tetsuro
    Obata, Takayuki
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2022, 21 (02) : 253 - 256
  • [39] 4D Flow MRI Applications for Aortic Disease
    Burris, Nicholas S.
    Hope, Michael D.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2015, 23 (01) : 15 - +
  • [40] Abdominal applications of quantitative 4D flow MRI
    Oechtering, Thekla H.
    Roberts, Grant S.
    Panagiotopoulos, Nikolaos
    Wieben, Oliver
    Roldan-Alzate, Alejandro
    Reeder, Scott B.
    ABDOMINAL RADIOLOGY, 2022, 47 (09) : 3229 - 3250