BP-Net: Cuff-less and non-invasive blood pressure estimation via a generic deep convolutional architecture

被引:7
|
作者
Zabihi, Soheil [1 ]
Rahimian, Elahe [2 ]
Marefat, Fatemeh [3 ]
Asif, Amir [1 ]
Mohseni, Pedram [3 ]
Mohammadi, Arash [2 ]
机构
[1] Concordia Univ, Elect & Comp Engn, 1455 Maisonneuve Blv W,EV 009-187, Montreal, PQ H3G 1M8, Canada
[2] Concordia Univ, Concordia Inst Informat Syst Engn, Montreal, PQ, Canada
[3] Case Western Reserve Univ, Elect Comp & Syst Engn, Cleveland, OH USA
基金
加拿大自然科学与工程研究理事会;
关键词
Continuous blood pressure (BP) estimation; Deep learning; Electrocardiograph (ECG); Photoplethysmograph (PPG); WAVE-FORM; KALMAN FILTER; TIME;
D O I
10.1016/j.bspc.2022.103850
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The paper focuses on development of robust and accurate processing solutions for continuous and cuff-less blood pressure (BP) monitoring. In this regard, a robust deep learning-based framework is proposed for computation of low latency and continuous upper and lower bounds on the systolic and diastolic BP.Methods: Referred to as the BP-Net, the proposed framework is a novel convolutional architecture that provides longer effective memory while achieving superior performance due to incorporation of casual dialated convolutions and residual connections. To utilize the real potential of deep learning in extraction of intrinsic features (deep features) and enhance the long-term robustness, the BP-Net uses raw Electrocardiograph (ECG) and Photoplethysmograph (PPG) signals without extraction of any form of hand-crafted features as it is common in existing solutions. Results: By capitalizing on the fact that datasets used in recent literature are not unified and properly defined, a benchmark dataset is constructed from the MIMIC-I and MIMIC-III databases obtained from PhysioNet. The proposed BP-Net is evaluated based on this benchmark dataset demonstrating promising performance and shows superior generalizable capacity. Conclusion: The proposed BP-Net architecture is more accurate than canonical recurrent networks and enhances the long-term robustness of the BP estimation task. Significance: The proposed BP-Net architecture addresses key drawbacks of existing BP estimation solutions, i.e., relying heavily on extraction of hand-crafted features, such as pulse arrival time (PAT), and; Lack of robustness. Finally, the constructed BP-Net dataset provides a unified base for evaluation and comparison of deep learning-based BP estimation algorithms.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Symmetrical Photoplethysmogram Signal-Based Cuff-Less Blood Pressure Estimation
    Liu, Zehua
    Xiao, Linxia
    Liu, Yang
    Gao, Liyu
    Zhang, Jinlong
    Si, Weixin
    IEEE SENSORS JOURNAL, 2024, 24 (06) : 8902 - 8911
  • [42] Blood pressure behavior in OSA patients analysed before and during CPAP therapy using a continuous, non-invasive and cuff-less method
    Kuechler, G.
    Patzak, A.
    JOURNAL OF SLEEP RESEARCH, 2016, 25 : 356 - 356
  • [43] Accuracy of cuff-less, continuous, and non-invasive blood pressure measurement in 24-h ABPM in children aged 5-17
    Bothe, Tomas L.
    Hulpke-Wette, Martin
    Barbarics, Boris
    Patzak, Andreas
    Pilz, Niklas
    BLOOD PRESSURE, 2023, 32 (01)
  • [44] Cuff-less blood pressure estimation using hetero-core optical fibers
    Koyama, Yuya
    Kamada, Hiroki
    Watanabe, Kazuhiro
    Nishiyama, Michiko
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2024, 107 (01)
  • [45] Cuff-Less Blood Pressure Estimation Using Only the ECG Signal in Frequency Domain
    Mousavi, Seyedeh Somayyeh
    Hemmati, Mohammad
    Charmi, Mostafa
    Moghadam, Maryam
    Firouzmand, Mohammad
    Ghorbani, Yadollah
    2018 8TH INTERNATIONAL CONFERENCE ON COMPUTER AND KNOWLEDGE ENGINEERING (ICCKE), 2018, : 147 - 152
  • [46] Development and Internal Validation of an AI-Enabled Cuff-less, Non-invasive Continuous Blood Pressure Monitor Across All Classes of Hypertension
    Lopez-Jimenez, Francisco
    Deshmukh, Abhishek
    Bisognano, John
    Boehmer, John
    Ramasamy, Mouli
    Shyam Kumar, Prashanth
    Kapa, Suraj
    Varadan, Venk
    Varadan, Vijay
    Fudim, Marat
    JOURNAL OF CARDIOVASCULAR TRANSLATIONAL RESEARCH, 2025, : 280 - 290
  • [47] Cuff-less Blood Pressure Estimation Using Hetero-core Optical Fibers
    Koyama Y.
    Kamada H.
    Watanabe K.
    Nishiyama M.
    IEEJ Transactions on Sensors and Micromachines, 2023, 143 (11) : 365 - 372
  • [48] BrainZ-BP: A Noninvasive Cuff-Less Blood Pressure Estimation Approach Leveraging Brain Bio-Impedance and Electrocardiogram
    Yang, Bufang
    Liu, Le
    Wu, Wenxuan
    Zhou, Mengliang
    Liu, Hongxing
    Ning, Xinbao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 13
  • [49] ESTIMATION OF CENTRAL AORTIC BLOOD PRESSURE FROM NON-INVASIVE CUFF PRESSURE OSCILLATION SIGNALS VIA SYSTEM IDENTIFICATION
    Ghasemi, Zahra
    Kim, Chang-Sei
    Ginsberg, Eric
    Duell, John
    Gupta, Anuj
    Hahn, Jin-Oh
    PROCEEDINGS OF THE ASME 9TH ANNUAL DYNAMIC SYSTEMS AND CONTROL CONFERENCE, 2016, VOL 1, 2017,
  • [50] A cause for a non-invasive blood pressure cuff leak
    Phan, T. D.
    Walpole, A. G.
    ANAESTHESIA AND INTENSIVE CARE, 2006, 34 (06) : 826 - 827