BP-Net: Cuff-less and non-invasive blood pressure estimation via a generic deep convolutional architecture

被引:7
|
作者
Zabihi, Soheil [1 ]
Rahimian, Elahe [2 ]
Marefat, Fatemeh [3 ]
Asif, Amir [1 ]
Mohseni, Pedram [3 ]
Mohammadi, Arash [2 ]
机构
[1] Concordia Univ, Elect & Comp Engn, 1455 Maisonneuve Blv W,EV 009-187, Montreal, PQ H3G 1M8, Canada
[2] Concordia Univ, Concordia Inst Informat Syst Engn, Montreal, PQ, Canada
[3] Case Western Reserve Univ, Elect Comp & Syst Engn, Cleveland, OH USA
基金
加拿大自然科学与工程研究理事会;
关键词
Continuous blood pressure (BP) estimation; Deep learning; Electrocardiograph (ECG); Photoplethysmograph (PPG); WAVE-FORM; KALMAN FILTER; TIME;
D O I
10.1016/j.bspc.2022.103850
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The paper focuses on development of robust and accurate processing solutions for continuous and cuff-less blood pressure (BP) monitoring. In this regard, a robust deep learning-based framework is proposed for computation of low latency and continuous upper and lower bounds on the systolic and diastolic BP.Methods: Referred to as the BP-Net, the proposed framework is a novel convolutional architecture that provides longer effective memory while achieving superior performance due to incorporation of casual dialated convolutions and residual connections. To utilize the real potential of deep learning in extraction of intrinsic features (deep features) and enhance the long-term robustness, the BP-Net uses raw Electrocardiograph (ECG) and Photoplethysmograph (PPG) signals without extraction of any form of hand-crafted features as it is common in existing solutions. Results: By capitalizing on the fact that datasets used in recent literature are not unified and properly defined, a benchmark dataset is constructed from the MIMIC-I and MIMIC-III databases obtained from PhysioNet. The proposed BP-Net is evaluated based on this benchmark dataset demonstrating promising performance and shows superior generalizable capacity. Conclusion: The proposed BP-Net architecture is more accurate than canonical recurrent networks and enhances the long-term robustness of the BP estimation task. Significance: The proposed BP-Net architecture addresses key drawbacks of existing BP estimation solutions, i.e., relying heavily on extraction of hand-crafted features, such as pulse arrival time (PAT), and; Lack of robustness. Finally, the constructed BP-Net dataset provides a unified base for evaluation and comparison of deep learning-based BP estimation algorithms.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Wearable Cuff-Less Blood Pressure Estimation at Home via Pulse Transit Time
    Ganti, Venu G.
    Carek, Andrew M.
    Nevius, Brandi N.
    Heller, J. Alex
    Etemadi, Mozziyar
    Inan, Omer T.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2021, 25 (06) : 1926 - 1937
  • [22] Cuff-less blood pressure estimation from Photoplethysmography via weighted visibility graph
    Liu, Yin-Song
    Yu, Jun-Sheng
    Mou, Han-Lin
    2022 CROSS STRAIT RADIO SCIENCE & WIRELESS TECHNOLOGY CONFERENCE, CSRSWTC, 2022,
  • [23] 24-hour ambulatory blood pressure measurement using a novel non-invasive, cuff-less, wireless device
    Nachman, D.
    Gilan, A.
    Goldstein, N.
    Constantini, K.
    Littman, R.
    Eisenkrafta, A.
    Grossmanc, E.
    Gepnerc, Y.
    EUROPEAN HEART JOURNAL, 2021, 42 : 2343 - 2343
  • [24] 24-HOUR AMBULTORY BLOOD PRESSURE MEASUREMENT USING A NOVEL NON-INVASIVE, CUFF-LESS, WIRELESS DEVICE
    Eisenkraft, Arik
    JOURNAL OF HYPERTENSION, 2022, 40 (SUPPL) : E103 - E103
  • [25] BP-Net: Efficient Deep Learning for Continuous Arterial Blood Pressure Estimation using Photoplethysmogram
    Vardhan, Rishi K.
    Vedanth, S.
    Poojah, G.
    Abhishek, K.
    Kumar, Nitish M.
    Vijayaraghavan, Vineeth
    20TH IEEE INTERNATIONAL CONFERENCE ON MACHINE LEARNING AND APPLICATIONS (ICMLA 2021), 2021, : 1495 - 1500
  • [26] USING A NOVEL NON-INVASIVE, CUFF-LESS, WIRELESS DEVICE FOR 24-HOUR AMBULATORY BLOOD PRESSURE MONITORING
    Gepner, Yftach
    Nachman, Dean
    Gilan, Adi
    Goldstein, Nir
    Constantini, Keren
    Littman, Romi
    Eisenkraft, Arik
    Grossman, Ehud
    JOURNAL OF HYPERTENSION, 2021, 39 : E135 - E135
  • [27] A Novel Indicator for Cuff-Less Blood Pressure Estimation Based on Photoplethysmography
    Jiang, Hongyang
    Miao, Fen
    Gao, Mengdi
    Hong, Xi
    He, Qingyun
    Ma, He
    Li, Ye
    HEALTH INFORMATION SCIENCE, HIS 2016, 2016, 10038 : 119 - 128
  • [28] Distributed Model Architecture for Cuff-Less Blood Pressure Measurement System
    Dave T.
    Joshi M.
    Pandya U.
    SN Computer Science, 3 (6)
  • [29] Cuff-less blood pressure estimation from photoplethysmography signal and electrocardiogram
    Yao, Li-Ping
    Pan, Zhong-liang
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2021, 44 (02) : 397 - 408
  • [30] Cuff-Less Blood Pressure Estimation From Photoplethysmography via Visibility Graph and Transfer Learning
    Wang, Weinan
    Mohseni, Pedram
    Kilgore, Kevin L.
    Najafizadeh, Laleh
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2022, 26 (05) : 2075 - 2085