BP-Net: Cuff-less and non-invasive blood pressure estimation via a generic deep convolutional architecture

被引:7
|
作者
Zabihi, Soheil [1 ]
Rahimian, Elahe [2 ]
Marefat, Fatemeh [3 ]
Asif, Amir [1 ]
Mohseni, Pedram [3 ]
Mohammadi, Arash [2 ]
机构
[1] Concordia Univ, Elect & Comp Engn, 1455 Maisonneuve Blv W,EV 009-187, Montreal, PQ H3G 1M8, Canada
[2] Concordia Univ, Concordia Inst Informat Syst Engn, Montreal, PQ, Canada
[3] Case Western Reserve Univ, Elect Comp & Syst Engn, Cleveland, OH USA
基金
加拿大自然科学与工程研究理事会;
关键词
Continuous blood pressure (BP) estimation; Deep learning; Electrocardiograph (ECG); Photoplethysmograph (PPG); WAVE-FORM; KALMAN FILTER; TIME;
D O I
10.1016/j.bspc.2022.103850
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: The paper focuses on development of robust and accurate processing solutions for continuous and cuff-less blood pressure (BP) monitoring. In this regard, a robust deep learning-based framework is proposed for computation of low latency and continuous upper and lower bounds on the systolic and diastolic BP.Methods: Referred to as the BP-Net, the proposed framework is a novel convolutional architecture that provides longer effective memory while achieving superior performance due to incorporation of casual dialated convolutions and residual connections. To utilize the real potential of deep learning in extraction of intrinsic features (deep features) and enhance the long-term robustness, the BP-Net uses raw Electrocardiograph (ECG) and Photoplethysmograph (PPG) signals without extraction of any form of hand-crafted features as it is common in existing solutions. Results: By capitalizing on the fact that datasets used in recent literature are not unified and properly defined, a benchmark dataset is constructed from the MIMIC-I and MIMIC-III databases obtained from PhysioNet. The proposed BP-Net is evaluated based on this benchmark dataset demonstrating promising performance and shows superior generalizable capacity. Conclusion: The proposed BP-Net architecture is more accurate than canonical recurrent networks and enhances the long-term robustness of the BP estimation task. Significance: The proposed BP-Net architecture addresses key drawbacks of existing BP estimation solutions, i.e., relying heavily on extraction of hand-crafted features, such as pulse arrival time (PAT), and; Lack of robustness. Finally, the constructed BP-Net dataset provides a unified base for evaluation and comparison of deep learning-based BP estimation algorithms.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Cuff-less blood pressure estimation from photoplethysmography signal and electrocardiogram
    Li-Ping Yao
    Zhong-liang Pan
    Physical and Engineering Sciences in Medicine, 2021, 44 : 397 - 408
  • [32] A novel non-invasive cuff-less optoelectronic sensor to measure blood pressure: comparison against intra-arterial measurement
    Lobo, Melvin
    Tucker, Arthur
    Burton, Maudrian
    McDonnell, Andrea
    Shah, Nita
    Shah, Sandeep
    O'Brien, Benjamin
    JOURNAL OF HUMAN HYPERTENSION, 2019, 33 : 5 - 5
  • [33] A NOVEL NON-INVASIVE CUFF-LESS OPTOELECTRONIC SENSOR TO MEASURE BLOOD PRESSURE: COMPARISON AGAINST INTRA-ARTERIAL MEASUREMENT
    Lobo, M.
    Tucker, A.
    Burton, M.
    McDonnell, A.
    Shah, N.
    Shah, S.
    O'Brien, B.
    JOURNAL OF HYPERTENSION, 2019, 37 : E158 - E158
  • [34] A Hybrid Deep Learning Approach for Cuff-less Noninvasive Continuous Blood Pressure Estimation Based on Photoplethysmography
    Ali, Md Sadek
    Islam, Md Shohidul
    Chan, Raymond Hon-Fu
    Chan, Kannie Wai Yan
    Ho, Derek
    2024 IEEE 3RD INTERNATIONAL CONFERENCE ON MICRO/NANO SENSORS FOR AI, HEALTHCARE, AND ROBOTICS, NSENS, 2024, : 35 - 40
  • [35] Continuous Cuff-Less Blood Pressure Estimation Based on Combined Information Using Deep Learning Approach
    Wu, Dan
    Xu, Lin
    Zhang, Ruiqin
    Zhang, Heye
    Ren, Lijie
    Zhang, Yuan-Ting
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2018, 8 (06) : 1290 - 1299
  • [36] Novel Deep Convolutional Neural Network for Cuff-less Blood Pressure Measurement Using ECG and PPG Signals
    Yan, Cong
    Li, Zhenqi
    Zhao, Wei
    Hu, Jing
    Jia, Dongya
    Wang, Hongmei
    You, Tianyuan
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 1917 - 1920
  • [37] Cuff-less and Calibration-free Blood Pressure Estimation Using Convolutional Autoencoder with Unsupervised Feature Extraction
    Zhang, Jialun
    Wu, Dan
    Li, Ye
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 3323 - 3326
  • [38] Cuff-less Blood Pressure Estimation Using Kalman Filter on Android Platform
    He, Zhengling
    Chen, Xianxiang
    Fang, Zhen
    Tang, Minfang
    Li, Junxia
    Xia, Shanhong
    2017 IEEE 19TH INTERNATIONAL CONFERENCE ON E-HEALTH NETWORKING, APPLICATIONS AND SERVICES (HEALTHCOM), 2017,
  • [39] Improving Cuff-Less Continuous Blood Pressure Estimation with Linear Regression Analysis
    Figini, Valeria
    Galici, Sofia
    Russo, Daniele
    Centonze, Ilenia
    Visintin, Monica
    Pagana, Guido
    ELECTRONICS, 2022, 11 (09)
  • [40] A Novel Method for Calibration-Based Cuff-Less Blood Pressure Estimation
    Li, Zhenqi
    Yan, Cong
    Zhao, Wei
    Hu, Jing
    Jia, Dongya
    Wang, Hongmei
    You, Tianyuan
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 4266 - 4269