The Role of Angle in the Evaluation of Ablation Accuracy in Pulmonary Vein Isolation Navigated by Image Integration

被引:0
|
作者
Chen, Song-Wen [1 ]
Cai, Li-Dong [1 ]
Asakawa, Tetsuya [2 ,3 ]
Zhou, Gen-Qing [1 ]
Wei, Yong [1 ]
Qi, Bao-Zhen [1 ]
Ling, Zhi-Yu [1 ]
Wu, Hai-Qing [1 ]
Xu, Juan [1 ]
Liu, Shao-Wen [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Cardiol, Sch Med, 100 Haining Rd, Shanghai 200080, Peoples R China
[2] Hamamatsu Univ Sch Med, Dept Neurosurg, Higashi Ku, Handayama 1-20-1, Hamamatsu, Shizuoka 4313192, Japan
[3] Fujian Univ Tradit Chinese Med, Res Base Tradit Chinese Med Syndrome, Fuzhou, Fujian, Peoples R China
来源
HEART SURGERY FORUM | 2018年 / 21卷 / 06期
基金
日本学术振兴会;
关键词
CATHETER ABLATION; CLINICAL-OUTCOMES; EFFICACY; IMPACT; CT;
D O I
10.1532/hsf.2231
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The conventional index for ablation accuracy is to compare the distance between mapping points with and without treatment by using image integration. We attempted to quantitatively evaluate the role of angle as an index in the ablation accuracy in patients with atrial fibrillation (AF). Methods: A total of 48 patients with AF were included in the present study. Virtual fluoroscopy planes were predicted by pulmonary vein (PV) angiography, and the standard image planes were defined on the basis of the computed tomography images. Ablations were performed, guided by image integration; and the ablation planes were defined by the actual ablation rings. The predicted angle (distance) was defined as the angle (distance) between the fluoroscopy (predicted) plane and image (standard) plane, whereas the actual angle (distance) was defined as the angle (distance) between the ablation (actual) planes and the image (standard) planes. Results: We found that all actual angles were significantly smaller than the predicted angles (P <. 05), but only the actual distances in the left PV, right inferior PV, right superior PV, and right PV were significantly smaller; the distances in the left inferior PV and left superior PV were not significantly different (P >. 05). Conclusion: Our finding indicates that both the angle and the distance can be significantly reduced by navigation with image integration, but that the angle exhibited better sensitivity than the conventional index of distance. We suggest that the angle should be considered as a new index for ablation accuracy.
引用
收藏
页码:E438 / E442
页数:5
相关论文
共 50 条
  • [1] The important role of pulmonary vein carina ablation as an adjunct to circumferential pulmonary vein isolation
    Udyavar, Ameya R.
    Chang, Shih-Lin
    Tai, Ching-Tai
    Lin, Yenn-Jiang
    Lo, Li-Wei
    Tuan, Ta-Chuan
    Tsao, Hsuan-Ming
    Hsieh, Ming-Hsiung
    Hu, Yu-Feng
    Chiang, Shuo-Ju
    Chen, Yi-Jen
    Wongcharoen, Wanwarang
    Higa, Satoshi
    Ueng, Kwo-Chang
    Chen, Shih-Ann
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2008, 19 (06) : 593 - 598
  • [2] CARTO-MERGE CAN IMPROVE THE ABLATION ACCURACY FOR PULMONARY VEIN ISOLATION
    Chen, Songwen
    Chen, Gang
    Ying Zhuge
    Zhang, Feng
    Meng, Weidong
    Yan, Yiwen
    Liu, Shaowen
    HEART, 2012, 98 : E226 - E226
  • [3] Cryoballoon ablation for pulmonary vein isolation
    Andrade, Jason G.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (08) : 2128 - 2135
  • [4] Cryoballoon Localization Using Image Integration During Pulmonary Vein Isolation
    Sra, Jasbir
    Agarwal, Anuj
    Krum, David
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (06) : 718 - 718
  • [5] Long-term clinical outcomes of magnetically navigated rotor ablation as an adjunct to conventional pulmonary vein isolation
    Shukla, Gunjan
    Zimmerman, John
    Shir, Zoya
    Shah, Roshan
    Hasanaj, Edmund
    EUROPACE, 2018, 20 : 40 - 47
  • [6] Pulmonary vein isolation using radiofrequency ablation
    Iden L.
    Busch S.
    Steven D.
    Tilz R.R.
    Shin D.-I.
    Chun K.J.
    Estner H.
    Bourier F.
    Duncker D.
    Sommer P.
    Metzner A.
    Maurer T.
    Ewertsen N.-C.
    Jansen H.
    Rillig A.
    Johnson V.
    Althoff T.
    Herzschrittmachertherapie + Elektrophysiologie, 2021, 32 (3) : 395 - 405
  • [7] Pulmonary vein stenosis after pulmonary vein ablation catheter-guided pulmonary vein isolation
    De Greef, Yves
    Schwagten, Bruno
    De Keulenaer, Gilles
    Stockman, Dirk
    HEART RHYTHM, 2010, 7 (09) : 1306 - 1308
  • [8] A multicentered evaluation of ablation at higher power guided by ablation index: Establishing ablation targets for pulmonary vein isolation
    Dhillon, Gurpreet
    Ahsan, Syed
    Honarbakhsh, Shohreh
    Lim, Wei
    Baca, Marco
    Graham, Adam
    Srinivasan, Neil
    Sawhney, Vinit
    Sporton, Simon
    Schilling, Richard J.
    Chow, Anthony
    Ginks, Matthew
    Sohal, Manav
    Gallagher, Mark M.
    Hunter, Ross J.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (03) : 357 - 365
  • [9] Ipsilateral pulmonary vein isolation performed by a single continuous circular lesion: role of pulmonary vein mapping during ablation
    Fuernkranz, Alexander
    Julian, K. R. Chun Julian
    Schmidt, Boris
    Wohlmuth, Peter
    Tilz, Roland
    Kuck, Karl-Heinz
    Ouyang, Feifan
    EUROPACE, 2011, 13 (07): : 935 - 941
  • [10] DOES PULMONARY VEIN ANATOMY PLAY A ROLE FOR ACUTE SUCCESS OF PULMONARY VEIN ISOLATION USING THE ENDOSCOPIC ABLATION SYSTEM?
    Gunawardene, M.
    Chun, K. R. J.
    Schulte-Hahn, B.
    Windhorst, V.
    Bordignon, S.
    Nowak, B.
    Schmidt, B.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 : S106 - S107