The Role of Angle in the Evaluation of Ablation Accuracy in Pulmonary Vein Isolation Navigated by Image Integration

被引:0
|
作者
Chen, Song-Wen [1 ]
Cai, Li-Dong [1 ]
Asakawa, Tetsuya [2 ,3 ]
Zhou, Gen-Qing [1 ]
Wei, Yong [1 ]
Qi, Bao-Zhen [1 ]
Ling, Zhi-Yu [1 ]
Wu, Hai-Qing [1 ]
Xu, Juan [1 ]
Liu, Shao-Wen [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Cardiol, Sch Med, 100 Haining Rd, Shanghai 200080, Peoples R China
[2] Hamamatsu Univ Sch Med, Dept Neurosurg, Higashi Ku, Handayama 1-20-1, Hamamatsu, Shizuoka 4313192, Japan
[3] Fujian Univ Tradit Chinese Med, Res Base Tradit Chinese Med Syndrome, Fuzhou, Fujian, Peoples R China
来源
HEART SURGERY FORUM | 2018年 / 21卷 / 06期
基金
日本学术振兴会;
关键词
CATHETER ABLATION; CLINICAL-OUTCOMES; EFFICACY; IMPACT; CT;
D O I
10.1532/hsf.2231
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The conventional index for ablation accuracy is to compare the distance between mapping points with and without treatment by using image integration. We attempted to quantitatively evaluate the role of angle as an index in the ablation accuracy in patients with atrial fibrillation (AF). Methods: A total of 48 patients with AF were included in the present study. Virtual fluoroscopy planes were predicted by pulmonary vein (PV) angiography, and the standard image planes were defined on the basis of the computed tomography images. Ablations were performed, guided by image integration; and the ablation planes were defined by the actual ablation rings. The predicted angle (distance) was defined as the angle (distance) between the fluoroscopy (predicted) plane and image (standard) plane, whereas the actual angle (distance) was defined as the angle (distance) between the ablation (actual) planes and the image (standard) planes. Results: We found that all actual angles were significantly smaller than the predicted angles (P <. 05), but only the actual distances in the left PV, right inferior PV, right superior PV, and right PV were significantly smaller; the distances in the left inferior PV and left superior PV were not significantly different (P >. 05). Conclusion: Our finding indicates that both the angle and the distance can be significantly reduced by navigation with image integration, but that the angle exhibited better sensitivity than the conventional index of distance. We suggest that the angle should be considered as a new index for ablation accuracy.
引用
收藏
页码:E438 / E442
页数:5
相关论文
共 50 条
  • [41] Is pulmonary vein isolation still the cornerstone in atrial fibrillation ablation?
    Bunch, T. Jared
    Cutler, Michael J.
    JOURNAL OF THORACIC DISEASE, 2015, 7 (02) : 132 - 141
  • [42] Durability of pulmonary vein isolation by various kind of ablation catheter
    Kobori, A.
    Sasaki, Y.
    Matsumoto, Y.
    Ishizu, K.
    Nakashima, M.
    Ishibashi, K.
    Murai, R.
    Oota, M.
    Kim, K.
    Yamane, T.
    Ehara, N.
    Kinoshita, M.
    Kaji, S.
    Furukawa, Y.
    EUROPEAN HEART JOURNAL, 2016, 37 : 632 - 632
  • [43] Identification and Endocardial Ablation of the Ligament of Marshall for Pulmonary Vein Isolation
    Chee, Jennifer
    Kalogeropoulos, Andreas P.
    Almasry, Ibrahim
    Singh, Abhijeet
    Rashba, Eric
    Fan, Roger
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2021, 7 (03) : 283 - 291
  • [44] Circumferential ablation with pulmonary vein isolation in permanent atrial fibrillation
    Cheema, Aamir
    Dong, Jun
    Dalal, Darshan
    Marine, Joseph E.
    Henrikson, Charles A.
    Spragg, David
    Cheng, Alan
    Nazarian, Saman
    Bilchick, Kenneth C.
    Almasry, Ibrahim
    Sinha, Sunil
    Scherr, Daniel
    Halperin, Henry
    Berger, Ronald
    Calkins, Hugh
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (10): : 1425 - 1428
  • [45] Midline ablation beyond pulmonary vein isolation? "The MiLine study"
    Cheng, Wen-Han
    Liao, Ying-Chieh
    Chen, Shih-Ann
    HEART RHYTHM, 2023, 20 (05) : 666 - 667
  • [46] Pulsed Field Ablation for Pulmonary Vein Isolation in Atrial Fibrillation
    Reddy, Vivek Y.
    Neuzil, Petr
    Koruth, Jacob S.
    Petru, Jan
    Funosako, Moritoshi
    Cochet, Hubert
    Sediva, Lucie
    Chovanec, Milan
    Dukkipati, Srinivas R.
    Jais, Pierre
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 74 (03) : 315 - 326
  • [47] Pulmonary Vein Isolation with a Novel Direct Visualization Ablation Catheter
    McElderry, Tom
    Oley, Leslie
    Malchano, Zaxh
    Wylie, Bryan
    Yamada, Takumi
    Kay, G. N.
    CIRCULATION, 2010, 122 (21)
  • [48] Finding the right timing in cryoballoon ablation for pulmonary vein isolation
    Eickholt, C.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 255 : 99 - 100
  • [49] SUCCESSFUL ABLATION OF A MULTIFOCAL ATRIAL TACHYCARDIA BY PULMONARY VEIN ISOLATION
    Methachittiphan, Nilubon
    Woodbury, Brandon
    Kroman, Anne
    Kulandhaisamy, Suresh Kumar
    Akoum, Nazem
    Mahankali, Arun Sridhar
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (09) : 2649 - 2649
  • [50] Acute Cardiac Tamponade as a Complication of Pulmonary Vein Isolation Ablation
    Tsai, Jeffrey
    Chishinga, Nathaniel
    Mannil, Shibinath Velutha
    Schaffer, Robin
    Kuchciak, Andrzej
    Gomez, Sabas I.
    Dylewski, John
    Sciarra, John
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (11)