The Role of Angle in the Evaluation of Ablation Accuracy in Pulmonary Vein Isolation Navigated by Image Integration

被引:0
|
作者
Chen, Song-Wen [1 ]
Cai, Li-Dong [1 ]
Asakawa, Tetsuya [2 ,3 ]
Zhou, Gen-Qing [1 ]
Wei, Yong [1 ]
Qi, Bao-Zhen [1 ]
Ling, Zhi-Yu [1 ]
Wu, Hai-Qing [1 ]
Xu, Juan [1 ]
Liu, Shao-Wen [1 ]
机构
[1] Shanghai Jiao Tong Univ, Shanghai Gen Hosp, Dept Cardiol, Sch Med, 100 Haining Rd, Shanghai 200080, Peoples R China
[2] Hamamatsu Univ Sch Med, Dept Neurosurg, Higashi Ku, Handayama 1-20-1, Hamamatsu, Shizuoka 4313192, Japan
[3] Fujian Univ Tradit Chinese Med, Res Base Tradit Chinese Med Syndrome, Fuzhou, Fujian, Peoples R China
来源
HEART SURGERY FORUM | 2018年 / 21卷 / 06期
基金
日本学术振兴会;
关键词
CATHETER ABLATION; CLINICAL-OUTCOMES; EFFICACY; IMPACT; CT;
D O I
10.1532/hsf.2231
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The conventional index for ablation accuracy is to compare the distance between mapping points with and without treatment by using image integration. We attempted to quantitatively evaluate the role of angle as an index in the ablation accuracy in patients with atrial fibrillation (AF). Methods: A total of 48 patients with AF were included in the present study. Virtual fluoroscopy planes were predicted by pulmonary vein (PV) angiography, and the standard image planes were defined on the basis of the computed tomography images. Ablations were performed, guided by image integration; and the ablation planes were defined by the actual ablation rings. The predicted angle (distance) was defined as the angle (distance) between the fluoroscopy (predicted) plane and image (standard) plane, whereas the actual angle (distance) was defined as the angle (distance) between the ablation (actual) planes and the image (standard) planes. Results: We found that all actual angles were significantly smaller than the predicted angles (P <. 05), but only the actual distances in the left PV, right inferior PV, right superior PV, and right PV were significantly smaller; the distances in the left inferior PV and left superior PV were not significantly different (P >. 05). Conclusion: Our finding indicates that both the angle and the distance can be significantly reduced by navigation with image integration, but that the angle exhibited better sensitivity than the conventional index of distance. We suggest that the angle should be considered as a new index for ablation accuracy.
引用
收藏
页码:E438 / E442
页数:5
相关论文
共 50 条
  • [31] Radiofrequency Catheter Ablation Targeting the Vein of Marshall in Difficult Mitral Isthmus Ablation or Pulmonary Vein Isolation
    Lee, Ji Hyun
    Nam, Gi-Byoung
    Kim, Minsu
    Hwang, You Mi
    Hwang, Jongmin
    Kim, Jun
    Choi, Kee-Joon
    Kim, You-Ho
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2017, 28 (04) : 386 - 393
  • [32] Preclinical evaluation of semi-automated laser ablation for pulmonary vein isolation: A comparative study
    Kuroki, Kenji
    Reddy, Vivek Y.
    Iwasawa, Jin
    Kawamura, Iwanari
    Neuzil, Petr
    Estabrook, Brian
    Melsky, Gerald
    Dukkipati, Srinivas R.
    Koruth, Jacob
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (02) : 315 - 324
  • [33] Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation
    Van Belle, Y.
    Thornton, A. S.
    Rivero-Ayerza, M.
    Jansse, P.
    Jordaens, L.
    EUROPEAN HEART JOURNAL, 2006, 27 : 42 - 43
  • [34] Vagal impact of cryoballoon ablation during pulmonary vein isolation
    Chang, Ting-Yung
    Lin, Chin-Yu
    Chen, Shih-Ann
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 265 : 132 - 133
  • [35] First report of phrenic nerve injury during pulmonary vein isolation using the Ablation Frontiers pulmonary vein ablation catheter
    Ahsan, Syed Y.
    Flett, Andrew S.
    Lambiase, Pier D.
    Segal, Oliver R.
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2010, 29 (03) : 187 - 190
  • [36] First report of phrenic nerve injury during pulmonary vein isolation using the Ablation Frontiers pulmonary vein ablation catheter
    Syed Y. Ahsan
    Andrew S. Flett
    Pier D. Lambiase
    Oliver R. Segal
    Journal of Interventional Cardiac Electrophysiology, 2010, 29 : 187 - 190
  • [37] Reproducibility of acute pulmonary vein isolation guided by the ablation index
    Solimene, Francesco
    Lepillier, Antoine
    De Ruvo, Ermenegildo
    Scaglione, Marco
    Anselmino, Matteo
    Sebag, Frederic A.
    Pecora, Domenico
    Gallagher, Mark M.
    Rillo, Mariano
    Viola, Graziana
    Rossi, Luca
    De Santis, Valerio
    Landolina, Maurizio
    Castro, Antonello
    Grimaldi, Massimo
    Badenco, Nicolas
    Del Greco, Maurizio
    De Simone, Antonio
    Bertaglia, Emanuele
    Stabile, Giuseppe
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (07): : 874 - 881
  • [38] Superior vena cava isolation by right pulmonary vein ablation
    Yagishita, Atsuhiko
    Yamauchi, Yasuteru
    Hirao, Kenzo
    EUROPACE, 2014, 16 (03): : 346 - 346
  • [39] Pulmonary vein isolation and linear lesions in atrial fibrillation ablation
    Sheikh, Imran
    Krum, David
    Cooley, Ryan
    Dhala, Anwer
    Blanck, Zalmen
    Bhatia, Atul
    Nangia, Vikram
    Akhtar, Masood
    Sra, Jasbir
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2006, 17 (02) : 103 - 109
  • [40] Epicardial ganglionated plexi isolation: an adjunct to pulmonary vein ablation?
    Floria, Mariana
    De Roy, Luc
    Blommaert, Dominique
    Collet, Benoit
    Alsteen, Gladys
    Dormal, Fabien
    Deceun-inck, Olivier
    Collard, Edith
    La Meir, Mark
    ACTA CARDIOLOGICA, 2008, 63 (01) : 93 - 93