A multicentered evaluation of ablation at higher power guided by ablation index: Establishing ablation targets for pulmonary vein isolation

被引:88
|
作者
Dhillon, Gurpreet [1 ]
Ahsan, Syed [1 ]
Honarbakhsh, Shohreh [1 ]
Lim, Wei [1 ]
Baca, Marco [1 ]
Graham, Adam [1 ]
Srinivasan, Neil [1 ]
Sawhney, Vinit [1 ]
Sporton, Simon [1 ]
Schilling, Richard J. [1 ]
Chow, Anthony [1 ]
Ginks, Matthew [2 ]
Sohal, Manav [3 ,4 ]
Gallagher, Mark M. [3 ,4 ]
Hunter, Ross J. [1 ]
机构
[1] Barts Hlth NHS Trust, St Bartholomews Hosp, Barts Heart Ctr, Dept Cardiac Electrophysiol, London EC1A 7BE, England
[2] Oxford Univ Hosp NHS Fdn Trust, John Radcliffe Hosp, Oxford Heart Ctr, Dept Cardiol, Oxford, England
[3] St George Hosp, Dept Cardiol, London, England
[4] St Anthony Hosp, Dept Cardiol, Sutton, Surrey, England
关键词
ablation index; atrial fibrillation; pulmonary vein isolation; CONTACT FORCE; ATRIAL-FIBRILLATION; RADIOFREQUENCY ABLATION; CATHETER ABLATION; RECONNECTION; TRIAL;
D O I
10.1111/jce.13813
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Pulmonary vein isolation (PVI) using high power delivered by SmartTouch Surround Flow (STSF) catheters guided by ablation index (AI) was evaluated in a multicenter registry. Methods Patients with paroxysmal AF underwent PVI with STSF catheters using 30 W on the posterior wall and 40 W elsewhere. AI targets were 350 posterior walls and 450 elsewhere. Procedures were compared with controls using conventionally irrigated contact force-sensing catheters using conventional powers (25 W posterior wall and 30 W elsewhere) guided by force-time integral (no agreed targets). The waiting period of 30 minutes was observed before adenosine administration to assess acute pulmonary vein (PV) reconnection. Results One hundred patients from four centers were included: 50 patients in the high power ablation index (HPAI) group and 50 controls. Procedure time was 22% shorter in the HPAI group (156 [133.8-179] vs 199 [178.5-227] minutes; P < 0.001). Duration of the radiofrequency application was 37% shorter in the HPAI group (27.2 [21.5-35.8] vs 43.2 [35.1-52.1] minutes; P < 0.001). Acute PV reconnection was reduced (28 of 200 [14%] vs 48 of 200 [24%] veins; P = 0.015). Reconnection was predicted by a largest interlesion distance greater than 6 mm, a lesion with impedance drop less than 2.5 omega, contact force less than 6 g, or less than 68% of the regional AI target (all P < 0.001). Freedom from atrial arrhythmia at 1 year off antiarrhythmic drugs after a single procedure was 78% in the HPAI group vs 64% in the control group (P = 0.186). Conclusion High-powered ablation guided by AI was safe and led to shorter procedure times with reduced acute PV reconnection compared with conventional ablation.
引用
收藏
页码:357 / 365
页数:9
相关论文
共 50 条
  • [1] Reproducibility of acute pulmonary vein isolation guided by the ablation index
    Solimene, Francesco
    Lepillier, Antoine
    De Ruvo, Ermenegildo
    Scaglione, Marco
    Anselmino, Matteo
    Sebag, Frederic A.
    Pecora, Domenico
    Gallagher, Mark M.
    Rillo, Mariano
    Viola, Graziana
    Rossi, Luca
    De Santis, Valerio
    Landolina, Maurizio
    Castro, Antonello
    Grimaldi, Massimo
    Badenco, Nicolas
    Del Greco, Maurizio
    De Simone, Antonio
    Bertaglia, Emanuele
    Stabile, Giuseppe
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2019, 42 (07): : 874 - 881
  • [2] Extensive Posterior Wall Isolation on Top of Pulmonary Vein Isolation Guided by Ablation Index in Persistent Atrial Fibrillation Ablation
    Sabatino, Francesco
    Oriente, Domenico
    Fortunato, Fabrizio
    Cascino, Antonio
    Ferrara, Giuliano
    Sgarito, Giuseppe
    Conti, Sergio
    LIFE-BASEL, 2023, 13 (03):
  • [3] A multicentered evaluation of the waiting period after PVI guided by the Ablation Index
    De Campos, D.
    Sousa, P.
    Adao, L.
    Primo, J.
    Khoueiry, Z.
    Lebreiro, A.
    Fonseca, P.
    Lagrange, P.
    Elvas, L.
    Goncalves, L.
    EUROPEAN HEART JOURNAL, 2021, 42 : 374 - 374
  • [4] Time to isolation guided hot balloon ablation for pulmonary vein isolation
    Chikata, A.
    Kato, T.
    Usuda, K.
    Fujita, S.
    Maruyama, M.
    Otowa, K.
    Takashima, S.
    Murai, H.
    Usui, S.
    Furusho, H.
    Kaneko, S.
    Takamura, M.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1793 - 1793
  • [5] Ablation index-guided ablation with milder targets for atrial fibrillation: Comparison between high power and low power ablation
    Liu, Zheng
    Liu, Li-feng
    Liu, Xiao-qin
    Liu, Jiapeng
    Wang, Yu-xin
    Liu, Ye
    Liu, Xing-peng
    Yang, Xin-chun
    Chen, Mu-lei
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [6] Tailored ablation index for pulmonary vein isolation according to wall thickness within the ablation circle
    Wang, Yong
    Zhou, Genqing
    Chen, Songwen
    Wei, Yong
    Lu, Xiaofeng
    Xu, Juan
    Wu, Xiaoyu
    Liu, Shaowen
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2021, 44 (04): : 575 - 585
  • [7] Comparison of advanced generation cryoballoon ablation and ablation index-guided pulmonary vein isolation with non-pulmonary vein trigger induction test and additional ablation in paroxysmal atrial fibrillation
    Egami, Yasuyuki
    Nishino, Masami
    Nohara, Hiroaki
    Kawanami, Shodai
    Sugae, Hiroki
    Ukita, Kohei
    Kawamura, Akito
    Nakamura, Hitoshi
    Yasumoto, Koji
    Tsuda, Masaki
    Okamoto, Naotaka
    Matsunaga-Lee, Yasuharu
    Yano, Masamichi
    Tanouchi, Jun
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (07) : 1571 - 1580
  • [8] Ablation index-guided ablation versus second-generation cryoballoon for first pulmonary vein isolation in atrial fibrillation
    Felix-Oliveira, A.
    Carmo, J.
    Carmo, P.
    Cavaco, D.
    Fontes, A.
    Rodrigues, G.
    Matos, D.
    Moscoso Costa, F.
    Bello Morgado, F.
    Adragao, P.
    Carvalho, S.
    EUROPEAN HEART JOURNAL, 2019, 40 : 1212 - 1212
  • [9] Performance and Safety of Temperature- and Flow-Controlled Radiofrequency Ablation in Ablation Index-Guided Pulmonary Vein Isolation
    Almorad, Alexandre
    Wielandts, Jean-Yves
    El Haddad, Milad
    Knecht, Sebastien
    Tavernier, Rene
    Kobza, Richard
    Phlips, Thomas
    Vijgen, Johan
    Berte, Benjamin
    Duytschaever, Mattias
    JACC-CLINICAL ELECTROPHYSIOLOGY, 2021, 7 (03) : 408 - 409
  • [10] Biophysical parameters of pulmonary vein isolation with very high-power short-duration compared to conventional radiofrequency ablation guided by ablation index
    Duarte, F. Fabiana
    Silva-Teixeira, R.
    Almeida, J. Goncalves
    Fonseca, P.
    Oliveira, M.
    Goncalves, H.
    Primo, J.
    Fontes-Carvalho, R.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 6 - 6